LCM SYSTEMS

SBL-3 500 lb

Rated load (lb) 200,500,100,025,005,000
Rated load (kg) 9,122,745,411,342,260
Accuracy class OIML R60 C3
Maximum number of verification intervals 3000
Minimum number of verification intervals E/11,500
Temperature effect on minium dead load output ≤± 0.00122% of rated load/˚C
Temperature effect on sensitivity  ≤± 0.001% of rated load/˚C
Safe load limit 200% of rated load
Ultimate load 300% of rated load
Safe side load 100% of rated load
Output  2mV/V (±0.1%) at rated load 
Zero balance ≤±5% of rated load
Combined error ≤±0.02% of rated load
Non-linearity ≤±0.0166% of rated load
Hysteresis   ≤±0.0166% of rated load
Creep error (30 minutes)   ≤±0.0166% of rated load
Excitation voltage 5 to 15V 
Input resistance 1100Ω ±50
Output resistance  1000Ω ±2
Insulation resistance  >5000MΩ @ 100vdc
Operating temperature range - 20 to +65°C (-20 to +60°C for ATEX version)
Compensated temperature range -10 to +40°C
Sealing  Potted
 Environmental protection level IP67
Connection type 3 metres PUR screened cable  via cable gland
Wiring connections  +ve supply: Green +ve signal : White Shield: Yellow -ve supply: Black -ve signal: Red