Rated load (lb) |
500, 1000, 2500, 5000, 10,000 |
Rated load (kg) |
227, 454, 1134, 2268, 4536 |
Accuracy class |
OIML R60 C3 |
Maximum number of verification intervals |
3000 |
Minimum number of verification intervals |
E/11,500 |
Temperature effect on minium dead load output |
≤± 0.00122% of rated load/˚C |
Temperature effect on sensitivity |
≤± 0.001% of rated load/˚C |
Safe load limit |
200% of rated load |
Ultimate load |
300% of rated load |
Safe side load |
100% of rated load |
Output |
2mV/V (±0.1%) at rated load |
Zero balance |
≤±5% of rated load |
Combined error |
≤±0.02% of rated load |
Non-linearity |
≤±0.0166% of rated load |
Hysteresis |
≤±0.0166% of rated load |
Creep error (30 minutes) |
≤±0.0166% of rated load |
Excitation voltage |
5 to 15V |
Input resistance |
1100Ω ±50 |
Output resistance |
1000Ω ±2 |
Insulation resistance |
>5000MΩ @ 100vdc |
Operating temperature range |
- 40 to +80°C (-40 to +60°C for ATEX version) |
Compensated temperature range |
-10 to +40°C |
Environmental protection level |
IP68 (up to 2m water depth) |
Connection type |
3 mtr screened cable (4.5 mtr for 10klb) |
Wiring connections |
+ve supply: Green +ve signal : White Shield: Yellow -ve supply: Black -ve signal: Red |