Switch-Tek™ LZ12 Vibration Level Switch


     

DOWNLOADS

 

Application

The general purpose vibration point level switch provides reliable liquid level detection of dirty liquids such as those with light to medium coating, scaling or foaming characteristics with a 1A relay output. Media examples include wastewater, diluted caustic soda and light weight oil. For optimum performance, the liquid level switch automatically adjusts for coating build up, and if necessary, outputs a proactive maintenance alarm to request cleaning. The submersible Ryton® liquid level sensor is universally mounted through the tank wall or inside the tank as a high level alarm or low level alarm.

Features

 

 Automatic coating adjustment optimizes sensor performance

 Submersible Ryton® sensor with polypropylene cable for corrosive liquids

 Coating alarm proactively alerts user when cleaning is required

 60VA relay selectable NO or NC via power supply wiring polarity

 Compatible with Smart Trak and Switch-Pak installation fittings

Specifications

Orientation: Universal
Accuracy: ± 1mm in water
Repeatibility: ± 0.5mm in water
Supply voltage: 12-28 VDC
Consumption: 25 mA maximum
Contact type: (1) SPST relay
Contact rating: 60 VA, 1A maximum
Contact output: Selectable NO / NC
Maint. alarm: NPN transistor, 10 mA
maximum
Process temp.: F: -40° to 176°
C: -40° to 80°
Pressure: 150 psi (10 bar) @ 25º
C., derated @ 1.667
psi (0.113 bar) per ºC.
above 25º C.
Sensor rating: NEMA 6 (IP68)
Sensor material: Ryton®
Grommet mat.: Viton®
Cable jack. mat.: PP
Cable type: 5-conductor, shielded
Cable length: 10' (3m)
Process mount: 3/4" NPT (3/4" G)
Mount. gasket: Viton®
Classification: General purpose
Compliance: CE
 
 

 

Product and Technology News

Chemical Batch Mix Tank Ultrasonic Level Measurement

Product Selector

Flowline

Application Selector

Flowline

Download Catalogue