ATM.ECO/IS - Analog Transmitter with Temperature Compensation
 

DOWNLOADS

 

 

OVERVIEW

 

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
  • Materials: Stainless steel
  •  

Customer benefits

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
  • Materials: Stainless steel
Back to Top
SPECIFICATIONS

Pressure measuring range (bar)

  0.1 ... 0.5, (1) > 0.5 ... 2 > 2 ... 100
Overpressure 3 bar 3 x FS (≥ 3 bar) 3 x FS
Burst pressure, (4) > 200 bar > 200 bar > 850 bar
Accuracy, (5), (± % FS) ≤ 0.25 ≤ 0.25 ≤ 0.25
Total Error, (6), (± % FS)      
0 ... 70°C, (typ. / max.) ≤ 1.0 / 1.5 ≤ 0.7 / 1.0 ≤ 0.7 / 1.0
-25 ... 100°C, (typ. / max.) ≤ 2.0 / 2.5 ≤ 1.0 / 1.5 ≤ 1.0 / 1.5
Response time, (typ.) < 1ms / 10 ... 90% FS < 1ms / 10 ... 90% FS < 1ms / 10 ... 90% FS
Long term stability, (7) < 0.5% FS / < 4 mbar < 0.2% FS / < 4 mbar < 0.1% FS / < 0.2% FS
  > 100 ... 600, (2) > 600 ... 1000, (3)
Overpressure 3 x FS (≤ 850 / ≤ 1500 bar) 1500 bar
Burst pressure, (4) > 850 / ≤ 1500 bar > 1500 bar
Accuracy, (5), (± % FS) ≤ 0.25 ≤ 0.25
Total Error, (6), (± % FS)    
0 ... 70°C, (typ. / max.) ≤ 0.7 / 1.0 ≤ 0.7 / 1.0
-25 ... 100°C, (typ. / max.) ≤ 1.0 / 1.5 ≤ 1.0 / 1.5
Response time, (typ.) < 1ms / 10 ... 90% FS < 1ms / 10 ... 90% FS
Long term stability, (7) < 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS

Electrical specifications

  4 ... 20 mA
Power supply 9 ... 28 VDC
Supply influence < 0.05% FS
Circuit diagram
Load resistance
Load influence < 0.05% FS

ATEX Approval

  [SpalteLeer] [SpalteLeer] [SpalteLeer]
Certificate, (1) SEV 09 ATEX 0108 X IECEx SEV 10.0003 X IECEx MSC 14.0002 X
Gas II 1G Ex ia IIB/IIC T3 ... T6 EN 60079-0 / -11 / -26  
Dust II 1D Ex ia IIIC IP6x T140°C ... T70°C EN 61241-0 / -11  
Mining I M1 Ex ia I EN 50303  
Temperature class, (2) T6 T4 T3
Process temperature -40 ... 50 °C -40 ... 100 °C -40 ... 150 °C
Ambient temperature -40 ... 50°C -40 ... 90°C -40 ... 125°C
Maximum values of the intrinsically safe circuit 28V / 93 mA / 0.65W    

Physical specifications

Back to Top

CERTIFICATES

 

 Certificate of compliance FMC ATM.xxx-IS STS E

 Certificate of compliance FM ATM.xxx-IS STS E

 IECEx SEV 10.0003X Issue 2

 SEV09-ATEX 0108X ATEX ATM.xxx STS E

 
 

 

Product and Technology News

Conductivity, Temperature, Depth

Product Selector

STS

Application Selector

STS

Download Catalogue