optoNCDT ILD1420-25

Brand : Micro-Epsilon
Type : Laser Sensor
Model : optoNCDT ILD1420-25
Measuring ranges : 25 mm
Start of measuring range : 25 mm
Mid of measuring range : 37.5 mm
End of measuring range : 50 mm
Linearity : < ±20 µm
Repeatability : 1 µm
Temperature stability :±0.015% FSO/K
Protection class : IP65 
Supply voltage : 11 … 30 VDC
Power consumption : < 2 W (24 V)
Measuring rate : 8 kHz / 4 kHz / 2 kHz / 1 kHz / 0.5 kHz / 0.25 kHz
Light source : Semiconductor laser < 1 mW, 670 nm (red)
Signal input : 1 x HTL laser on/off;
                      1 x HTL multifunction input: trigger in / zero setting / mastering / teach
Switching output : 1 x error output: npn, pnp, push pull
Analog output : 4 ... 20 mA / 1 … 5 V with PCF1420-3/U cable (12 bit)
Digital interface : RS422 (16 bit) / EtherCAT / PROFINET  / EtherNet/IP
(Remark: EtherCAT / PROFINET / EtherNet/IP connection via interface module.)

Sub Components

PS2020

Power supply unit (all optoNCDT series)

Input 100-240 VAC 

Output 24 VDC / 2.5 A

mounting onto symmetrical standard rail 35 mm x 7.5 mm, DIN 50022



Add

PCF1420-1/I

Supply and output cable (drag-chain suitable)

PCF1420-1/I (1 m, output 4 ... 20 mA)

Add

PCF1420-1/I(01)

Supply and output cable (drag-chain suitable)

PCF1420-1/I(01) (1 m, output 4...20 mA)

Add

PCF1420-3/I

Supply and output cable (drag-chain suitable)

PCF1420-3/I (3 m, output 4 ... 20 mA)

Add

PCF1420-6/I

Supply and output cable (drag-chain suitable)

PCF1420-6/I (6 m, output 4 ... 20 mA)

Add

PCF1420-10/I

Supply and output cable (drag-chain suitable)

PCF1420-10/I (10 m, output 4 ... 20 mA)

Add

PCF1420-15/I

Supply and output cable (drag-chain suitable)

PCF1420-15/I (15 m, output 4 ... 20 mA)

Add

PCF1420-3/U

Supply and output cable (drag-chain suitable)

PCF1420-3/U (3 m, with integrated resistor, output 1 ... 5 VDC)

Add

PCF1420-6/U

Supply and output cable (drag-chain suitable)

PCF1420-6/U (6 m, with integrated resistor, output 1 ... 5 VDC)

Add

PCF1420-10/U

Supply and output cable (drag-chain suitable)

PCF1420-10/U (10 m, with integrated resistor, output 1 ... 5 VDC)

Add

PCF1420-15/U

Supply and output cable (drag-chain suitable)

PCF1420-15/U (15 m, with integrated resistor, output 1 ... 5 VDC)

Add

PCF1420-3/IF2008

Supply and output cable (drag-chain suitable)

PCF1420-3/IF2008 (3 m, interface and supply cable)

Add

PCF1420-6/IF2008

Supply and output cable (drag-chain suitable)

PCF1420-6/IF2008 (6 m, interface and supply cable)

Add

PCF1420-10/IF2008

Supply and output cable (drag-chain suitable)

PCF1420-10/IF2008 (10 m, interface and supply cable) 

Add

PCF1420-3/C-Box

Supply and output cable (drag-chain suitable)

PCF1420-3/C-Box (3 m)

Add

PCR1402-3/I

Supply and output cable, suitable for use with robots

PCR1402-3/I (3 m) 

Add

PCR1402-6/I

Supply and output cable, suitable for use with robots

PCR1402-6/I (6 m)

Add

PCR1402-8/I

Supply and output cable, suitable for use with robots

PCR1402-8/I (8 m) 

Add

C-Box/2A

C-Box/2A Controller for D/A conversion and evaluation of up to 2 sensor signals

C-Box/2A is used for fast D/A conversion of two digital input signals or for evaluating two digital sensor signals. The controller is compatible with the optoNCDT 1420, 1750, 1900 and 2300 models. Handling of the C-Box/2A and of the connected sensors are performed via web interface. Averaging functions, thickness, diameter, step and inclinations can be calculated. The D/A conversion is executed at 16 bit and max. 70 kHz.

Special features 

- Trigger input

- Multi-function output 

- Measurement value output via Ethernet, USB, analog output 4 ... 20 mA / 0 ... 5 V / 0 ... 10 V / ±5 V / ±10 V (scalable via web interface) 

- 2x switching outputs for sensors or C-Box/2A status 

- Parallel data output via three output interfaces

Add

IF2030/ENETIP

Interface module for Industrial Ethernet connection

The IF2030 interface modules are designed for easy connection of

Micro-Epsilon sensors to Ethernet-based fieldbuses, e.g., plant control systems. The PROFINET and Ethernet/IP modules are compatible with sensors that output data via an RS422 or RS485 interface. These modules operate on the sensor side with up to 4 MBd and have two network connections for different network topologies. Installation in control cabinets is via a DIN rail.

Add

IF2030/PNET

Interface module for Industrial Ethernet connection

The IF2030 interface modules are designed for easy connection of

Micro-Epsilon sensors to Ethernet-based fieldbuses, e.g., plant control systems. The PROFINET and Ethernet/IP modules are compatible with sensors that output data via an RS422 or RS485 interface. These modules operate on the sensor side with up to 4 MBd and have two network connections for different network topologies. Installation in control cabinets is via a DIN rail.

Add

IF2008PCIE

Interface card for synchronous data acquisition 

Absolute synchronous data acquisition is a decisive factor for the planarity or thickness measurement using several laser sensors. The IF2008PCIe interface card is designed for installation in PCs and enables the synchronous capture of four digital sensor signals and two encoders. The data is stored in a FIFO memory in order to enable resource-saving processing in blocks in the PC. The IF2008E expansion board enables to detect in addition two digital sensor signals, two analog sensor signals and eight I/O signals. 

Special features 

- IF2008PCIe - Basic printed circuit board: 4 digital signals and 2 encoders 

- IF2008E - Expansion board: 2x digital signals, 2x analog signals and 8x I/O signals

Add

IF2008E

Interface card for synchronous data acquisition 

Absolute synchronous data acquisition is a decisive factor for the planarity or thickness measurement using several laser sensors. The IF2008PCIe interface card is designed for installation in PCs and enables the synchronous capture of four digital sensor signals and two encoders. The data is stored in a FIFO memory in order to enable resource-saving processing in blocks in the PC. The IF2008E expansion board enables to detect in addition two digital sensor signals, two analog sensor signals and eight I/O signals. 

Special features 

- IF2008PCIe - Basic printed circuit board: 4 digital signals and 2 encoders 

- IF2008E - Expansion board: 2x digital signals, 2x analog signals and 8x I/O signals

Add

IF2008/ETH

IF2008/ETH Interface module for Ethernet connection with up to 8 sensors 

The IF2008/ETH integrates up to eight sensors and/or encoders with an RS422 interface into an Ethernet network. Four programmable switching in-/outputs (TTL and HTL logic) are available. Ten indicator LEDs directly on the module show both the channel and the device status. In addition, acquisition and output of data via Ethernet is in addition performed at high speeds up to 200 kHz. Parameter setting of the interface module can be easily done via the web interface.

Add

IC2001/USB

IC2001/USB Single-channel converter cable RS422/USB

The IC2001/USB single-channel converter cable is used for the USB connection of optoNCDT sensors equipped with an RS422 interface. The cable is easy to assemble and can therefore also be used for installation in machines and systems. 

Special features 

- 5-core interface cable without outer shield 

- Conversion from RS422 to USB 

- Easy sensor connection via USB 

- Supports baud rates from 9.6 kBaud to 1 MBaud

Add

IF2001/USB

IF2001/USB converter RS422 to USB 

The RS422/USB converter transforms digital signals from a laser-optical sensor into a USB data packet. The sensor and the converter are connected via the RS422 interface of the converter. Data output is done via USB interface. The converter loops through further signals and functions such as laser on/off, switch signals and function output. The connected sensors and the converter can be programmed through software. 

 Special features 

- Robust aluminum housing 

- Easy sensor connection via screw terminals (plug & play) 

- Conversion from RS422 to USB 

- Supports baud rates from 9.6 kBaud to 12 MBaud

Add

IF2004/USB

IF2004/USB: 4-channel converter from RS422 to USB

The RS422/USB converter is used for transforming digital signals from up to four optical sensors into USB data signals. The converter has four trigger inputs and a trigger output for connecting additional converters. Data is output via an USB interface. The connected sensors and the converter can be programmed through software. 

Special features 

- 4x digital signals via RS422 

- 4x trigger inputs, 1x trigger output 

- Synchronous data acquisition 

- Data output via USB

Add

IF2035-PROFINET

Interface module for PROFINET connection of a Micro-Epsilon sensor with RS485 or RS422 interface, suitable for PCF1420-x/I or PCF1420-x/U cables, top-hat rail housing, incl. GSDML file for software integration in the PLC

Add

IF2035-EIP

Interface module for connection of Micro-Sensors with RS422/RS485 interface to Ethernet/IP 1-channel system with DIN rail housing Software integration into the PLC with EDS file Certified according to Ethernet/IP CT16

Add

IF2035-EtherCAT

Interface module for EtherCAT connection of a Micro-Epsilon sensor with RS485 or RS422 interface, suitable for PCF1420-x/I or PCF1420-x/U cables, top-hat rail housing, incl. ESI file for software integration in the PLC

Add

Protective film

Protective film

Transparent protective film 32 x 11 mm for ILD1x20

Add