| Rated Load (RL): 0,5, 1, 2, 3, 5 t |
| Combined error: ±0.02 % RO |
| Repeatability: ±0.01 % RO |
| Creep (20 minutes): ±0.017 % RO |
| Safe overload: 150 % RL |
| Ultimate overload: 300 % RL |
| Clamping force without any load: RL 500÷2000 kg: 136 Nm; RL 3000÷5000kg: 205 Nm |
| Material: Stainless steel |
| Degree of protection: IP68 |
| Accuracy class: 3000 OIML |
| Deflection: 0.2 ÷ 1.4 mm |
| Compensated Temperature: -10 ÷ +40°C |
| Temperature range: -18 ÷ +65°C |
| Temperature effect on zero balance: 0.018 % RO/10°C |
| Temperature effect on output: 0.012 % output/10°C |
| Rated output RO: 2 mV/V ± 0.25% |
| Zero balance: ±1 % RO |
| Insulation resistance: > 1000 M Ohm |
| Input resistance: 343 ÷ 357 Ohm |
| Output resistance: 349 ÷ 355 Ohm |
| Recommended input: 5 ÷ 15 Vdc/Vac |