Rated Load (RL): 5, 10, 20, 30, 50 t |
Combined error: 0.02 % RO |
Repeatability: ±0.01 % RO |
Creep (30 minutes): ±0.0170% on applied load |
Safe overload: 150 % RL |
Ultimate overload: 300 % RL |
Material: Stainless steel |
Degree of protection: IP68 |
Accuracy class: 3000 OIML, NTEP |
Compensated Temperature: -10 ÷ +40 °C |
Temperature range: -30 ÷ +70 °C |
Temperature effect on zero balance: 0.0010 % RO/°C |
Temperature effect on output: 0.0010 % on output/°C |
Rated output RO: 2 mV/V ± 0.1% |
Zero balance: ±2 % RO |
Insulation resistance: > 2000 M Ohm |
Input resistance: 1065 ±60 Ohm |
Output resistance: 1025 ±20 Ohm |
Recommended input: 5 ÷ 15 Vdc/ac |
Maximum supply voltage: 20 Vdc/ac |
Y = Emax/Vmin: 14000 |
Max number of intervals: 3000 |
Cable Lenght: 5m (5t), 10m (10 & 20t), 20m (30 & 50t) |