LCM SYSTEMS

SBL-24 2500 lb

Rated load (lb) 500, 1000, 2500, 5000, 10,000
Rated load (kg) 227, 454, 1134, 2268, 4536
Accuracy class OIML R60 C3
Maximum number of verification intervals 3000
Minimum number of verification intervals E/11,500
Temperature effect on minium dead load output ≤± 0.00122% of rated load/˚C
Temperature effect on sensitivity  ≤± 0.001% of rated load/˚C
Safe load limit 200% of rated load
Ultimate load 300% of rated load
Safe side load 100% of rated load
Output  2mV/V (±0.1%) at rated load 
Zero balance ≤±5% of rated load
Combined error ≤±0.02% of rated load
Non-linearity ≤±0.0166% of rated load
Hysteresis   ≤±0.0166% of rated load
Creep error (30 minutes)   ≤±0.0166% of rated load
Excitation voltage 5 to 15V 
Input resistance 1100Ω ±50
Output resistance  1000Ω ±2
Insulation resistance  >5000MΩ @ 100vdc
Operating temperature range - 40 to +80°C (-40 to +60°C for ATEX version)
Compensated temperature range -10 to +40°C
 Environmental protection level IP68 (up to 2m water depth)
Connection type 3 mtr screened cable (4.5 mtr for 10klb)
Wiring connections  +ve supply: Green +ve signal : White Shield: Yellow -ve supply: Black -ve signal: Red