IOT GATEWAY with 4G Connectivity | for WIFI Sensors

 
 
Product Reference
WILOW-IOT-GATEWAY-4G-REG-NET-PWR
REG: LTE Region Option EU for Europe - US for North America - JP for Japan
NET: Network option for WDS function - wireless distribution system (not available if you choose Solar Power Supply)
*MPWR: Mains power supply with UPS Battery (Input: 90 to 264VAC)
*SOLAR - Solar Power supply ( not compatible with WDS function)
Example 1: WILOW-IOT-GATEWAY-4G-EU-MPWR, LTE Europe Region , Mains Power supply
Example 2: WILOW-IOT-GATEWAY-4G-JP-WDS-MPWPR, LTE Japan Region, WDS function, Mains power supply
Example 3: WILOW-IOT-GATEWAY-4G-US-SOLAR,  LTE US Region, Solar Power Supply
 
 
WIFI Connectivity specifications
Wireless Protocol
IEEE 802.11 b/g
WIFI confguration
Wireless AP, Station
If WDS Option is present: Bridge with WDS (Wireless Distribution System)
Operating frequency
2412-2462 MHz
Sensitivity
-74dBm to -90 dBm
DataRate
6 to 4 Mbps
Output power
If WDS Option is present: 28 dBm
If WDS option not present: 20dBm
High Gain Ominidrectionnal WIFI Antenna
Frequency range 2400-2500MHz
Gain:  9dBi, VSWR  < 1.2
Impedance 50 Ohm, Polarization Vertical
Beamwidth: Vertical plane 15°, Horizontal plane 360°
Dimensions: 540x23 mm, Weight: 0.61 kg
Connector:  N female, Wind load: (170km/h) 11 N
 
 
Remote Access and FTP Client
MQTT Broker
Integrated MQTT Broker , Default Port Number 1883 (Configurable from LTE Router)
Compatiblity with BeanScape® Wilow® software
Only comaptible with BeanScape® Wilow® RA
Embedded FTP Client
Embedded MQTT to FTP Client converter Compatible with Alarm and Low Duty Cycle Data Acquisition Mode
SMS Alarms
SMS Alarms , compatible with Alarm Data Acquisition only
 
 
3G/4G Connectivity specifications
LTE
■ LTE FDD (Europe): B1/B3/B5/B7/B8/B20/B28A
■ LTE FDD (Japan): B1/B3/B8/B18/B19/B26
■ LTE FDD (North America):  B2, B4, B12, B13
■ LTE TDD: B38/B40/B41
■ LTE CAT4 up to 70 Mbps DL
■ LTE CAT4 up to 50 Mbps UL
■ Class 3 (23dBm±2dB) for LTE FDD
■ Class 3 (23dBm±2dB) for LTE TDD
UMTS/DC-HSPA+
■ 850/900/2100 MHz
■ DC-HSPA+ mode: Max 42Mbps (DL) Max 5.76Mbps (UL)
■ UMTS mode: 384 kbps DL, 384 kbps UL
■ TD-SCDMA: Max 4.2Mbps (DL) Max 2.2Mbps (UL)
■ Power Class 3 (24dBm +1/-3dB) for UMTS bands
■ Class 3 (24dBm+1/-3dB) for TD-SCDMA
GSM/GPRS/EDGE
■ 900/1800 Mhz
■ GPRS/EDGE Multi-slot Class 12
■ Power Class E2 (27dBm ±3dB) for GSM 900
■ Power Class E2 (26dBm +3/-4dB) for DCS 1800
■ Power Class 4 (33dBm ±2dB) for GSM 900
■ Power Class 1 (30dBm ±2dB) for DCS 1800
Omnidirectionnal 4G Antenna
Omnidirectional 4G Antenna (2x2 MIMO)
Weather-resistant and UV-resistant plastic / PVC enclosure
VSWR < 1.8
Impendance: 50 Ohm
Beamwidth: 360° Horizontal - 20° Vertical
Gain :
8dBi @ 800 MHz
12dBi @ 1800MHz
12dBi @ 2600MHz
Frequency:
791-862 MHz (2G, 4G)
1700 - 2100 MHz (3G, 4G)
2500 - 2700 (4G)
Connectors: 2 x N female
Mounting Kit: U-clamp for 30-50mm diameter handles
 
 
Solar Panel power supply with UPS Battery (-SOLAR option is selected)
Battery
Valve Regulated Lead-Acid (VRLA)
Capacity 12Ah
Solar panel technology
Polycristalline 100W, anodized aluminum frame.
Surface protection with ESG solarglass.
Dimensions (LxWxH): 1005 x 670 x 35mm
Solar charging controller
Maximum Input current: 10A
Power consumption < 2.5mA , Led switch on
Nominal voltage :12VDC
Led displays: battery full and charging
Socket for AC power supply
Industrial and Waterproof Socket
Circular Socket CA 3 GD - Hirschmann
Rated Voltage: 400VA
Rated Current:16A
 
 
AC power supply with UPS battery (-MPWR option is selected)
Battery
Valve Regulated Lead-Acid (VRLA)
Capacity 12Ah
Battery protection
Overvoltage/Overload/Short circuit/Battery low/Battery reverse polarity
AC Voltage Range (Input)
90 to 264VAC
AC Range (Input)
0.75A/115VAC
0.5A/230VAC
Frequency Range
47 ~ 63Hz
Inrush current
Cold Start 20A/115VAC, 40A/230VAC
Safety and EMC
Safety standards: UL60950-1, TUV EN60950-1 approved
Withstand Voltage: I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation Resistance TANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission: Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
EMC immunity: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Socket for AC power supply
Industrial and Waterproof Socket
Circular Socket CA 3 GD - Hirschmann
Rated Voltage: 400VA
Rated Current:16A
 
 
Environmental and Mechanical
Casing
Steel enclosure with padlock adapter, Light gray color
Dimensions
25.4 cm x 20.3 cm x 15.24 cm
Weight
9.8 kg
IP|NEMA Rating
IP66 | Nema 6
Mounting Process
Screw mounting
Operating Temperature
Battery Charging:  -15°C to 50°C
Battery Discharging: -20°C to 60°C
Norms & Radio Certifications
. CE Labelling Directive R&TTE (Radio) ETSI EN 300 328 (Europe)
. FCC Part 15.247 (North America)
. ARIB STD-T66 Ver. 3.6 (Japan)
. IC RS210
. ROHS - Directive 2002/95/EC
 
 

 


Please register here in order to access the download page.
Name: *
Email address: *
Company Name: *
Designation: *
Contact No: *
 
  * Please filled in the required details.