Simplex and Multiplex Pump Control

0.33 hp – 200 hp (0.25 kW – 132 kW) Simplex Pump
0.5 hp – 200 hp (0.37 kW – 132 kW) Multiplex Pump

115 V | 208 - 240 V | 380 - 480 V | 575 V | 690 V

The Control Techniques Unidrive M400 Pumping Solutions are a cost effective and versatile variable speed control system for maintaining energy efficient, constant water pressure in single-phase (0.33 - 50 hp) or 3-phase (0.5 - 200 hp) applications. These single-pump and multi-pump (up to 3 max) configurations utilize the onboard controller on the Unidrive M400 variable frequency AC drive (VFD) for economical and easy to use control.

Based on the highly reliable Unidrive M400 AC drive, these solutions provide programming dedicated to simplex and multiplex pump operation. The AI-CTASP (Simplex Pump) and AI-CTAMP (Multiplex Pump) options include an AI-BACKUP-ADAPTOR with SD memory card pre-loaded with default pump parameters to make application setup easy.

Additionally, an optional HMI (human machine interface) is available that makes setup and diagnostics easy and provides additional features such as remote web access and email alerts.

 
 

The Control Techniques’ Unidrive M400 Simplex Pump solution is an effective and versatile variable speed control system for maintaining constant pressure in a single pump configuration for ratings up to 200 hp. Based on the highly reliable Unidrive M400 AC drive, this product offers cost effective pump control. An embedded controller in the drive eliminates the need for an external controller saving cost, space and programming time.

how does a vfd pumps simplex system work 

 

Standard Features
  •  Dynamic V/Hz Energy Savings Mode
  •  Built-in energy metering
  •  Wide power range – 0.5 hp to 200 hp
  •  Wide input power range: 115 V to 690 V
  •  Smooth S-ramp speed variation avoids water hammer
  •  Optional communications or expanded I/O (frame sizes 2 and up)
  •  Optional intelligent keypad with user units.
  •  Last 10 drive trips logged

 

Start / Stop and control modes
  •  Hand/Auto mode (via I/O)
  •  Pressure transducer and flow switch
  •  Pressure transducer only

 

Software operating features
  •  Pressure PID mode
  •  Sleep / wake mode
  •  Start / stop delay
  •  Multiple setpoint selection
  •  Configurable pipe fill operation
  •  Automatic fault reset

 

System protection functions
  •  Low suction detection / dry well detection
  •  Shared pressure feedback capacity / redundancy
  •  Transducer loss detection
  •  High / low pressure detect
  •  No flow detection
  •  Motor overload

 

Software configuration
  •  The Unidrive M400 Simplex Pump parameters can be configured from a PC using Connect software and an optional programming cable (CT-USB-CABLE) and RS485 adaptor (AI-485-ADAPTOR), or via a SI-ETHERNET option module.

 

Add CTVUE-306A-CTAMP HMI for additional features and benefits
  •  Easy system setup
  •  System trip log
  •  Historical flow monitoring
  •  Remote web access
  •  Email alerts

 

How to order

1.Order any Unidrive M400 part number and replace the last 5 digits of the order code with K0033 or K0035. This includes the preprogrammed Unidrive M400 with pump software and default pump configuration drive parameters, for example:

Standard Drive: M400-02400013A10101AB100 (with DB transistor) M400-09402000E10101AN100 (without DB transistor)

Multiplex Pump Drive: M400-02400013A10101K0033 (with DB transistor) M400-09402000E10101K0035 (without DB transistor)

2. Order CI-KEYPAD-LCD for access to drive parameters, status and diagnostics and to load SD card pump files from the AI-BACKUP-ADAPTOR. One keypad is recommended to be order at a minimum.

3. Order AI-CTAMP for pump configuration drive parameters for drives one, two and three. This includes an AI-BACKUP-ADAPTOR and SD card with default pump configuration drive parameters pre-loaded.

 
 

 


Please register here in order to access the download page.
Name: *
Email address: *
Company Name: *
Designation: *
Contact No: *
 
  * Please filled in the required details.