Key data
Heavy Duty rating: 0.33 hp - 150 hp (0.25 kW - 110 kW)
Normal Duty rating: 0.33 hp – 200 hp (0.25 kW – 132 kW)
Supply phases:
Size 1 to 4: 110 V drives – 1 phase, 230 and 400 V drives - 1 or 3 phase
Size 5 upwards: 3 phase
Standard features
Keypad:
M200: Fixed LED
M201: Fixed LED with speed reference potentiometer
Option slots:
1 (Size 2 and above)
Parameter cloning via:
PC tools
SD card with AI-Backup Adaptor
AI-Smart Adaptor
100 V (100 V - 120 V ± 10%)
|
✓
|
200 V (200 V - 240 V ± 10%)
|
✓
|
400 V (380 V - 480 V ± 10%)
|
✓
|
575 V (500 V - 575 V ± 10%)
|
✓
|
690 V (500 V - 690 V ± 10%)
|
Open-loop vector or V/Hz induction motor control
|
✓
|
Open-loop Rotor Flux Control for induction motors (RFC-A)
|
✓
|
Open-loop permanent magnet motor control (RFC-S)
|
|
Closed-loop Rotor Flux Control for induction motors (RFC-A)
|
|
Closed-loop permanent magnet motor control (RFC-S)
|
|
Active Front End (AFE) power quality convertor
|
|
|
mm
|
in
|
kg
|
lb
|
1
|
160 x 75 x 130
DIN rail mounting:
137 x 75 x 130
|
6.3 x 3.0 x 5.1
DIN rail mounting:
5.4 x 3.0 x 5.1
|
0.75 |
1.65 |
2
|
205 x 75 x 150
DIN rail mounting:
180 x 75 x 150
|
8.1 x 3.0 x 5.9
DIN rail mounting:
7.1 x 3.0 x 5.9
|
1.0 |
2.2 |
3
|
226 x 90 x 160 |
8.9 x 3.5 x 6.3 |
1.5 |
3.3 |
4
|
277 x 115 x 175 |
10.9 x 4.5 x 6.9 |
3.13 |
6.9 |
5
|
391 x 143 x 192
|
15.4 x 5.6 x 7.6
|
7.4
|
16.3
|
6
|
391 x 210 x 221 |
15.4 x 8.3 x 8.7 |
14 |
30.9 |
7 |
557 x 270 x 280 |
21.9 x 10.6 x 11.0 |
28 |
61.7 |
8 |
803 x 310 x 290 |
31.6 x 12.2 x 11.4 |
52 |
114.6 |
9A |
1108 x 310 x 290 |
43.6 x12.2 x 11.4 |
66.5 |
146.6 |
All dimensions include mounting brackets except for the DIN rail alternatives for frame size 1 and 2.