EchoPro® LR26 Pulse Radar Liquid Level Transmitter

DOWNLOADS

 

 

Application

The intrinsically safe 6.3 GHz. pulse radar transmitter provides continuous level measurement up to 114.8’ (35m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical and petroleum storage or process applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for harsh process conditions with corrosive or low dielectric media, heavy surface foam or agitation, higher pressure, steam, condensation or vapor, and installation in a flange fitting. Due to the wider beam angle, special attention should be given to ensure that the sensor is located with unobstructed measurement space. Typical applications include process tanks.

Features

316L antenna with PTFE inner shield for corrosive media

Configuration via push button display module

6.3 GHz. pulse radar is unaffected by most foam and agitation

12” (30cm) dead band enables utilization of the entire tank

LCD displays level in feet or meters with percent of span bar

Optional display mode indicates the echo signal return curve

HART communication in point to point and multi-drop modes

Auto-temperature compensation for accurate measurement

Fail-safe diagnostics with selectable signal fail-safe outputs

Recognition, storage and rejection of false echo signal returns

IP67 stainless enclosure with polycarbonate display window

 

Specifications

Range: 12" to 114.8" (30cm to 35m)
Frequency: 6.3 GHz.
Accuracy: ± 10mm
Dead band: 12" (30cm)
Beam angle: 20°
Configuration: Push button, WebCal® PC Windows® USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40° to 266° 
C: -40° to 130°
Temp. comp.: Automatic
Storage temp.: F: -40° to 176° 
C: -40° to 80°
Pressure: -14.5 to 58 psi (-1 to 40 bar)
Enclosure rating: IP67
Encl. material: 316L stainless stell w/silicone gasket 
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2" NPT connector 
Antenna material: 316L w/PTFE inner shield
Process mount: -40: 4'' flange (ANSI), -60: 6'' flange (ANSI)
Classification: Intrinsically safe
Certification: FCC
Compliance: CE, CRN, RoHS
 
 

 


Please register here in order to access the download page.