EchoPod® UG06 & UG12 Reflective Ultrasonic Liquid Level Transmitter

DOWNLOADS

 

 

Application

The general purpose reflective ultrasonic level transmitter provides continuous level measurement up to 39.3’ (12m) with a 4-20 mA analog signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.

Features

Offered in 6m (19.6’) and 12m (39.3’) measurement ranges

Reflective Technology™ measures reliably with condensation

Corrosion resistant PVDF transducer with IP68 PP enclosure

Fail-safe diagnostics with selectable signal fail-safe outputs

LCD display indicates level in inches, meters or percent of span

Narrow 3” (7.6cm) beam width for applications with limited space

Windowed enclosure cap provides liquid tight level indication

Configuration via push button display or WebCal software

Automatic temperature compensation from -40º to 80º C

Reflective

Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.

Reflective Transducer

Patent Pending

Reliable Measurement

Horizontal Transducer

Signal Attenuation

 

 

 

Specifications

Range: UG06: 8” to 19.6’ (20cm to 6m), UG12: 18” to 39.3’ (45.7cm to 12m)
Accuracy: ± 0.2% of range
Resolution: UG06: 0.079” (2mm), UG12: 0.196” (5mm)
Dead band: UG06: 8” (20.3cm), UG12: 18” (45.7cm)
Beam width: UG06: 3” (7.6cm), UG12: 6” (15.2cm)
Configuration: Push button or WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm or percent
Supply voltage: 14-28 VDC
Max. consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output:

4-20mA, two-wire

Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.:

F: -40º to 176º

C: -40º to 80º

Temp. comp.:

Automatic

Ambient temp.:

F: -31º to 140º

C: -35º to 60º

Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Encl. cap material: Clear polycarbonate
Enclosure vent: Water tight membrane
Conduit entrance: 1/2” NPT
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Process mount: -0001: 2” NPT, -0011: 2” G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approval (pending): UL 61010-1
Compliance: CE, RoHS
 
 

 