Display Specifications

Display type TFT Color LCD
Display size 4.3" wide
Resolution 480 x 272 pixels
Effective display area (W x H) W95 x H53.9 mm
Display colors 65,536 colors
Backlight White LED
(Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life 50,000 hours or more
Brightness control 16 levels (Adjusted with touch panel)

Electrical Specifications

Power supply Rated input voltage 12 to 24 Vdc
Input voltage limits 10.2 to 28.8 Vdc
Voltage drop 12 Vdc: 1 ms or less
24 Vdc: 3 ms or less
Power consumption When power is not supplied to USB devices 3.9 W or less
When power is supplied to USB devices 8.1 W or less
In-rush current 12 Vdc: 20 A or less
24 Vdc: 40 A or less
Voltage endurance 1,000 Vac, 20 mA for 1 minute (between charging and FG terminals)
Insulation resistance 500 Vdc, 10 MΩ or more (between charging and FG terminals)

Environmental Specifications

International safety standard
Physical environment Surrounding air temperature 0 to 50℃ (32 to 122 ℉) *1
Storage temperature -20 to 60℃ (-4 to 140℉)
Surrounding air and storage humidity 10% to 90% RH (Non condensing, wet bulb temperature 39 ℃ [102.2 ℉] or less)
Dust 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree For use in Pollution Degree 2 environment
Corrosive gases Free of corrosive gases
Atmospheric pressure (operating altitude) 800 to 1,114 hPa (2,000 m [6,561 ft.] or lower)
Mechanical environment Vibration resistance IEC/EN 61131-2 compliant
5 to 9 Hz Single amplitude 3.5 mm (0.14 in.)
9 to 150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approximately 100 min.)
Shock resistance IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Electrical environment Electrostatic discharge immunity Contact discharge method: 6 kV (IEC/EN 61000-4-2 Level 3)

Memory

Application memory 8 MB
Backup memory FLASH EPROM 128 KB *2

Interface Specifications

USB (Type A) interface Connector USB 2.0 (Type A) x 1
Power supply voltage 5 Vdc ±5%
Maximum current supplied 500 mA/port
Maximum transmission distance Less than 3 m (9.84 ft)
USB (mini-B) interface Connector USB 2.0 (mini-B) x 1
Maximum transmission distance Less than 3 m (9.84 ft)
Ethernet interface Standard IEEE802.3u, 10BASE-T/100BASE-TX
Connector Modular jack (RJ-45) x 1

Structural Specifications

Grounding Functional grounding: Grounding resistance of 100 Ω, 2 mm2 (AWG 14) or thicker wire, or your country's applicable standard (same for FG and SG terminals).
Cooling method Natural air circulation
Structure *3 IP65F, Type 1, Type 4X (Indoor Use only), Type 13
* on the front panel when properly installed in an enclosure.
External dimensions W124.9 x H90.4 x D38.8 mm (W4.92 x H3.56 x D1.53 in.)
Panel cutout dimensions W112.5 x H77.5 mm (W 4.43 x H3.05 in.)
with Panel Cutout Adapter (PFXZCFAD31, sold separately): W105 x H66 mm (W4.13 x H2.6 in.)
Weight 0.22 kg (0.49 lb) or less

External Dimensions

Dimensions

Panel Cut Dimensions

Panel Cut
W H X R
112.5 mm (+1/-0 mm)
(4.43 in. [+0.04/-0 in.])
77.5 mm (+1/-0 mm)
(3.05 in. [+0.04/-0 in.])
1.5 to 6 mm
(0.06 to 0.24 in.)
2 to 3 mm
(0.08 to 0.12 in.)
* with Panel Cutout Adapter (PFXZCFAD31, sold separately): W105 x H66 mm (W4.13 x H2.6 in.)

Dimensions with Installation Fasteners Attached

Descriptions

  1. *1     The designated range for the surrounding air temperature is 0 to 45 °C (32 to 113 °F) when the output current of
  2.           USB (Type A) interface is from 0.25 A to 0.5 A.
  3. *2     For details on the memory size, refer to the manual for your screen editing software.
  4. *3     The front face of this product, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though this product's level of resistance is equivalent to these standards, oils that should have no effect on this product can possibly harm this product. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to this product for long periods of time. If this product 's front face protection sheet peels off, these conditions can lead to the ingress of oil into this product and separate protection measures are suggested.
    Also, if non-approved oils are present, they may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing this product, be sure to confirm the type of conditions that will be present in this product 's operating environment. If the installation gasket is used for a long period of time, or if this product and its gasket are removed from the panel, the original level of protection cannot be kept. To maintain the original protection level, be sure to replace the installation gasket regularly.
 
 

 