Specification of FP3600-T41-24V
Model (Global Code): FP3600-T41-24V (PFXFP3600TD)
Functional Specification
Display Type |
TFT Color LCD |
Display Size |
12.1" |
Resolution |
800 x 600 pixels (SVGA) |
Dot pitch |
W0.3075 x H0.3075 mm [W0.01 x H0.01 in.] |
Effective Display Area |
W248 x H186.5 mm [W9.76 x H7.34 in.] |
Display Colors |
262,144 Colors |
Backlight |
CCFL (Replaceable) |
Brightness Control |
Adjusted with the OSD |
Contrast Control |
Adjusted with the OSD |
Backlight Service Life |
50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50% or backlight starts to blink) |
Touch Panel Type |
Resistive Film (analog) |
Touch Panel Resolution |
1,024 x 1,024 |
Touch Panel Service Life |
1,000,000 times or more |
Touch Panel Interface |
RS-232C or USB (USB2.0, TYPE-B) |
Interface |
Video |
Analog RGB input connector: mini D-Sub15 (socket) x 1,
DVI-D input, Connector: DVI-D 24 pin (socket) x 1*1 |
-
*1 FPs which have a mark in hardware revision "2" support DVI Hot Plug Detect function.
General Specification
International Safety Standards |
|
Rated Input Voltage |
DC 24 V |
Input Voltage Limits |
DC 19.2 to 28.8 V |
Allowable Voltage Drop |
10 ms or less |
Power Consumption |
50 W or less |
In-Rush Current |
30 A or less |
Voltage Endurance |
AC 1,000 V, 20 mA for 1 min (between charging and FG terminals) |
Insulation Resistance |
DC 500 V, 10 MΩ or more (between charging and FG terminals) |
Surrounding Air Temperature |
0 to 50 ℃ |
Storage Temperature |
-20 to +60 ℃ |
Ambient Humidity |
10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.) |
Storage Humidity |
10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.) |
Dust |
0.1 mg/m³ or less (non-conductive levels) |
Pollution Degree |
For use in Pollution Degree 2 environment |
Atmosphere |
Free of corrosive gases |
Air Pressure (altitude range) |
800 to 1,114 hPa (2,000 m above sea level or less) |
Vibration Resistance |
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min) |
Concussion Resistance |
IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times |
Noise Immunity |
Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator) |
Electrostatic Discharge Immunity |
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) |
Grounding |
Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) |
Structure |
Equivalent to IP65f (on the front panel when properly installed in an enclosure)*2 |
Installation Configuration |
Embedded panel |
Cooling Method |
Natural air circulation |
Weight Approx. |
3.5 kg [7.7 lb] or less (display unit only) |
External Dimensions |
W317 x H243 x D58 mm [W12.48 x H9.57 x D2.28 in.] |
Panel Cut Dimensions |
W301.5 x H227.5 mm [W11.87 x H8.96 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*3 |
-
*2 The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
-
*3 Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
External Dimensions / Interfaces / Panel Cut-out
|