Specification Comparison
|
LT Type B/B+/C |
GP-3300T/L |
|
Panel cut-out size difference.
Attachment (CA4-ATM5-01) available |
Model No. |
Type B+(Color) : GLC150-SC41-XY32KF-24V
Type B(Monochrome) : GLC150-BG41-FLEX-24V
Type B+(Monochrome) : GLC150-BG41-XY32KF-24V
Type C(Monochrome) : GLC150-BG41-RSFL-24V |
Color : AGP3300-T1-D24-FN1M
Monochrome : AGP3300-L1-D24-FN1M |
Display Type(Color) |
STN Color LCD |
UP!
TFT Color LCD |
Display Type(Monochrome) |
Monochrome blue mode LCD |
UP!
Monochrome LCD |
Display Colors(Color) |
64 colors |
UP!
65,536 colors (without blink)
16,384 colors (with blink) |
Display Colors(Monochrome) |
Monochrome blue mode, 8 levels |
Monochrome, 16 levels |
Display Resolution |
QVGA(320×240 pixels) |
Panel Cutout Dimensions (mm) |
W191.5×H141.5mm |
W156×H123.5mm*1 |
External Dimensions (mm) |
W207×H157×D75.8mm |
W167.5×H135×D78mm |
Touch Panel Type |
Resistive film (Matrix) |
NEW!
Resistive film (Analog)*1 |
Memory (Application) |
1MB |
UP!
6MB |
Memory (SRAM) |
96KB |
UP!
320KB |
Control Memory (Program) |
128KB |
UP!
132KB |
Control Memory (SRAM) |
32KB |
UP!
64KB |
Serial I/F (COM1) |
Type B :
-
Type B+ :
-
Type C :
D-Sub25pin (plug)
RS-232C/422 |
D-Sub9pin (plug)
RS-232C/422/485 |
Serial I/F (COM2) |
- |
D-Sub9pin (socket)
RS-422/485 |
Ethernet I/F |
- |
NEW!
10BASE-T/100BASE-TX |
FLEX NETWORK I/F |
✔ |
DIO I/F (COM1) |
Type B :
-
Type B+ :
DIO 32 points
Input : Sink/Source 16 points
Output : Sink 16 points
Type C :
- |
- |
CF Card I/F |
- |
NEW!
✔ *1 |
USB Host I/F |
- |
NEW!
✔(Type A) *1 |
Printer I/F |
- |
NEW!
USB *1 |
Alarm Output |
✔ |
- *1 |
*1 There are some restrictions regarding replacement with recommended substitutes.
*2 When LT Type B+ is replaced with GP-3300T/L, the I/O units that were connected to LT Type B+ via the DIO interface before replacement are connected via a FLEX NETWORK interface. A FLEX NETWORK unit is required.
When the display unit type is changed to AGP-3300T/L-FN1M, the I/O setting at the time of using LT Type B/B+/C is all cleared.
Check the setting of the LT Type B/B+/C project file (*.prw) and allocate I/O to the GP-3300T/L project file again.