Digital Block Gauge - Specification

 

Product (Body Width)
8 mm wide
12 mm wide
Axial Cable Outlet
DK/2
DK/5
DK/10
Radial Cable Outlet
DKR/2
DKR/5
DKR/10

 

Measurement Performance
Measurement Range (mm)
2
5
10
Accuracy (% of Reading) (Note 1)
0.05
0.05
0.08
Repeatability (µm) (Note 2)
<0.25
<0.25
<0.5
Resolution (µm)
0.01
0.05
0.05
Pre Travel (mm)
0.15
0.15
0.15
Post Travel (mm)
0.85
0.85
0.85
Tip Force (N) at Middle of Range ±20%
1.5
1.5
1.5
Temperture Coefficient (μm/ºC)
0.2
0.5
1

 

Environmental
Measurement Range (mm)
IP65
Accuracy (% of Reading) (Note 1)
-20 to +80
Repeatability (µm) (Note 2)
+5 to +80
Resolution (µm)
0 to 60
Pre Travel (mm)
EN61000-6-3
Post Travel (mm)
EN61000-6-2
Tip Force (N) at Middle of Range ±20%
Do not subject Block Gauge to excessuive shocks

 

Material
Block Gauge Body
Stainless Steel
Probe Tip (Options)
Nylon, Ruby, Silicon Nitride, Tungsten Carbide
Gaiter
Fluoroelastomer or Silicon
Cable
PUR
Electronics Module
ABS

 

Electronics Interface (Orbit® 3)
Orbit® Interface Options
USB, Ethernet, RS232
Reading Rate
3906 readings per second
Bandwidth of Electronics (Hz) user selectable
460, 230, 115, 58, 29, 14, 7,4
Power
5±0.25 VDC @ 0.06A typical

 

Note 1: Accuracy 0.1 μm or % reading (whichever greater) assumes 20 mm tip holder mounted on center, spring operation with                      standard springs. Offset tips, long arms etc may reduce performance.