AX/P Series |
Axial Cable Outlet (LVDT) |
AX/1/P |
AX/1.5/P |
AX/2.5/P |
AX5/1/P |
AX/5/P |
AX/10/P |
Axial Cable Outlet (Half Bridge) |
AX/1/PH |
AX/1.5/PH |
AX/2.5/PH |
AX5/1/PH |
AX/5/PH |
AX/10/PH |
Body Diameter |
8h6 |
Measurement Range (mm) |
± 1.0 |
± 1.5 |
± 2.5 |
± 1.0 |
± 5.0 |
± 10.0 |
Pre-Travel (mm) |
0.15 |
Over Travel (mm) |
0.85 |
8.85 |
0.85 |
Accuracy (% of reading or µm, whichever greater) |
0.5, 1.0 µm |
0.5, 1.5 µm |
0.5, 2.5 µm |
0.5, 1.0 µm |
0.5, 5.0 µm |
0.7, 10.0 µm |
Repeatability (µm) |
<0.15 |
Tip Force (N) at Centre Travel ± 20% |
0.8 @ 0.4 bar
2.8 @ 1 bar |
0.8 @ 0.4 bar
2.8 @ 1 bar |
0.85 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
Resolution |
Dependent on electronics |
Temperature Coefficient (% FS/°C) |
0.01 |
|
Electrical Interface |
LVDT Plugged |
Sensitivity1 (mV/V/mm) ± 0.5% |
200 |
133 |
80 |
200 |
40 |
20 |
Energising Current (mA/V ± 5%) |
1.8 |
2.0 |
2.0 |
1.8 |
2.0 |
1.0 |
LVDT Unplugged |
Sensitivity (mV/V/mm) ± 5% |
210 |
150 |
150 |
210 |
105 |
33 |
Half Bridge Plugged |
Sensitivity1 (mV/V/mm) ± 0.5% |
73.5 |
49.0 |
29.4 |
73.5 |
14.7 |
7.35 |
Energising Current (mA/V ± 5%) |
1.0 |
1.0 |
1.0 |
1.0 |
1.2 |
1.2 |
Half Bridge Unplugged |
Sensitivity ± 5% |
83 |
150 |
150 |
210 |
105 |
33 |
1Linearity and Sensitivity error combined does not exceed a total of 0.5%. |
Environmental |
Storage Temperature (°C) |
-40 to +100 |
Operating Temperature (°C) |
+5 to +80 |
IP Rating |
IP 65 |
|
Materials |
Case |
Stainless Steel |
Probe Tip |
Nylon and Tungsten Carbide |
Gaiter |
High Grade Polymer |
Cable |
2 m PUR
|