Analogue Signal Conditioner |
Power Requirements |
OD2 |
OD4 |
OD5 |
Voltage Range |
13 VDC to 42 VDC |
10 VDC to 30 VDC |
90 VAC to 264 VAC |
Current Range (mA) |
Up tp 30 |
140 @ 10 V to
50 @ 30 V |
250 @ 120 V to
100 at 250 |
Frequency Range (Hz) |
- |
47 to 63 |
|
Sensor Excitation |
Primary Voltage (Vrms) |
0 - 9 |
3 |
Primary Frequency (kHz) |
5 or 13 nominal |
2.5 or 5 nominal
10 or 13 nominal (Half Bridge variant) |
|
Signal Input (Sensor Sensitivity Range) |
Input Range |
30 to 530 mV/V1 |
55 mV to 5000 mV (LVDT Full Range) |
Input Load Resistance (kΩ) |
100 |
2, 10, 100 |
Options |
- |
Forward and Reverse polarity, Half Bridge |
1For sensors with a sensitivity greater than 530 mV/V, an adjustable attenuator is required. |
Signal Output |
Voltage Output (VDC) |
- |
Up to ± 10 |
Current Output (mA) |
4 - 20 (2 wire)
0 - 20 (4 wire) |
Up to ± 20 mA into 150 Ω load |
Output Ripple |
38 µA rms |
< 1 mVrms |
Output Offset |
Up to 100% Maximum Gain (Coarse and Fine adjustment) |
Temperature Coefficient Gain |
< 0.01% FRO/°C |
Temperature Coefficient Offset |
< 0.01% FRO/°C |
Warm Up Time |
15 Minutes (recommended) |
Linearity |
0.02% FRO |
0.1% FRO |
Bandwidth-3db (Hz) |
25 |
500 typical |
|
Environmental |
Operating Temperature Range |
0 to +60 °C (+32 to +140 °F) |
Storage Temperature Range |
-40 to +80 °C
(-42 to +176 °F) |
-20 to +85 °C
(-4 to +185 °F) |
IP Rating |
IP 65 |
IP 40 |
|
Mechanical and Connections |
Sensor |
Internal Terminal Block |
5 pin Circular DIN |
Power Supply |
Internal Terminal Block |
IEC320 C14 |
Output Signal |
Internal Terminal Block |
Enclosure Dimensions without Connectors (mm) |
120 x 80 x 54.5 |
120 x 60 x 40 |
Weight (g) |
220 |
300 |
Material |
Light Grey ABS |
Die-Cast Zinc Alloy (painted) |