DTM.OCS.S |
|
|
|
DOWNLOADS
|
|
|
|
OVERVIEW
Features
-
Pressure measuring range: 200 mbar…100 bar
-
Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
-
Operating temperature: -40…85 °C
-
Process temperature: -40…85 °C
-
Interface: RS485
-
Materials: Stainless steel, Titanium
-
Customer benefits
-
Pressure measuring range: 200 mbar…100 bar
-
Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
-
Operating temperature: -40…85 °C
-
Process temperature: -40…85 °C
-
Interface: RS485
-
Materials: Stainless steel, Titanium
|
|
Back to Top |
|
SPECIFICATIONS
|
|
0.2 ... 0.5 |
> 0.5 ... 2 |
> 2 ... 100 |
|
Overpressure |
3 bar |
3 x FS (≥ 3 bar) |
3 x FS |
|
Burst pressure, (1) |
> 200 bar |
> 200 bar |
> 200 bar |
|
Accuracy, (2), (± % FS) |
≤ 0.15 |
≤ 0.05 |
≤ 0.03 |
|
Total Error, (3) (4) (± % FS) |
|
|
|
|
-40...85°C (typ. / max.) |
≤ 0.8 / 1.5 |
≤ 0.3 / 0.5 |
≤ 0.1 / 0.2 |
|
-25...85°C (typ. / max.) |
≤ 0.5 / 1.0 |
≤ 0.2 / 0.4 |
≤ 0.1 / 0.2 |
|
0...70°C (typ./max.) |
≤ 0.3 / 0.8 |
≤ 0.1 / 0.2 |
≤ 0.1 / 0.2 |
|
Long term stability, (5) |
< 0.5% FS / < 4 mbar |
< 0.2% FS / < 4 mbar |
< 0.1% FS / < 0.2% FS |
|
|
0 ... 70 |
-25 ... 85 |
-40 ... 85°C |
|
Accuracy, (2) |
≤ ± 0.5 °C |
≤ ± 1.5 °C |
≤ ± 1.5 °C |
|
Response time, (3), (4) |
|
|
|
|
T 0.50 |
9 s |
9 s |
9 s |
|
T 0.90 |
27 s |
27 s |
27 s |
|
T 0.63 |
15 s |
15 s |
15 s |
|
|
|
|
Operating temperature |
-40...85 °C |
|
Process temperature |
-40...85 °C |
|
Storage temperature |
-40...85 °C |
|
|
|
|
Power supply (1) |
9...30 VDC |
|
Current consumption (typ.) |
3mA @ 24VDC |
|
Resolution |
|
|
Temperature |
0.1°C |
|
Pressure |
20 Bit |
|
Output |
|
|
Baudrate |
9600 bps |
|
Protocol |
Modbus RTU, 8n2 |
|
Interface |
RS485 |
|
Cable length (2) |
max. 1000m |
|
|
|
|
|
|