SPECIFICATIONS
|
0.1 ... 0.5, (1) |
> 0.5 ... 2 |
> 2 ... 100 |
Overpressure |
3 bar |
3 x FS (≥ 3 bar) |
3 x FS |
Burst pressure, (4) |
> 200 bar |
> 200 bar |
> 850 bar |
Accuracy, (5), (± % FS) |
≤ 0.25 |
≤ 0.25 |
≤ 0.25 |
Total Error, (6), (± % FS) |
|
|
|
0 ... 70°C, (typ. / max.) |
≤ 1.0 / 1.5 |
≤ 0.7 / 1.0 |
≤ 0.7 / 1.0 |
-25 ... 100°C, (typ. / max.) |
≤ 2.0 / 2.5 |
≤ 1.0 / 1.5 |
≤ 1.0 / 1.5 |
Response time, (typ.) |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
Long term stability, (7) |
< 0.5% FS / < 4 mbar |
< 0.2% FS / < 4 mbar |
< 0.1% FS / < 0.2% FS |
|
> 100 ... 600, (2) |
> 600 ... 1000, (3) |
Overpressure |
3 x FS (≤ 850 / ≤ 1500 bar) |
1500 bar |
Burst pressure, (4) |
> 850 / ≤ 1500 bar |
> 1500 bar |
Accuracy, (5), (± % FS) |
≤ 0.25 |
≤ 0.25 |
Total Error, (6), (± % FS) |
|
|
0 ... 70°C, (typ. / max.) |
≤ 0.7 / 1.0 |
≤ 0.7 / 1.0 |
-25 ... 100°C, (typ. / max.) |
≤ 1.0 / 1.5 |
≤ 1.0 / 1.5 |
Response time, (typ.) |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
Long term stability, (7) |
< 0.1% FS / < 0.2% FS |
< 0.1% FS / < 0.2% FS |
|
4 ... 20 mA |
Power supply |
9 ... 28 VDC |
Supply influence |
< 0.05% FS |
Circuit diagram |
|
Load resistance |
|
Load influence |
< 0.05% FS |
|
[SpalteLeer] |
[SpalteLeer] |
[SpalteLeer] |
Certificate, (1) |
SEV 09 ATEX 0108 X |
IECEx SEV 10.0003 X |
IECEx MSC 14.0002 X |
Gas |
II 1G Ex ia IIB/IIC T3 ... T6 |
EN 60079-0 / -11 / -26 |
|
Dust |
II 1D Ex ia IIIC IP6x T140°C ... T70°C |
EN 61241-0 / -11 |
|
Mining |
I M1 Ex ia I |
EN 50303 |
|
Temperature class, (2) |
T6 |
T4 |
T3 |
Process temperature |
-40 ... 50 °C |
-40 ... 100 °C |
-40 ... 150 °C |
Ambient temperature |
-40 ... 50°C |
-40 ... 90°C |
-40 ... 125°C |
Maximum values of the intrinsically safe circuit |
28V / 93 mA / 0.65W |
|
|
|