AT10
Weighing Instrumentation Weight Transmitters
DOWNLOADS
Datasheet
DIN rail mounting
Terminal 20-pin for the 4 load cells connection
Power supply 20 ÷ 28 Vdc
Input signal from 3 to 30mV
Adjustment Zero and Full Scale by dip-switch and multi-turn trimmer
TECHNICAL SPECIFICATIONS AT10
Power supply:
24 Vdc ± 15%
Cells Power:
10 Vdc (max 4 x 350 ohm cells)
Maximum power:
6 W
Analog outputs:
0 to 5 VDC, 0 to 10 VDC, 0 to 20 mA, 4 ÷ 20 mA
Full scale (FS):
3 ÷ 30 mV / V
Linearity:
± 0.02% FS
Operating temperature:
-10 to +50 ° C (max 85% relative humidity without condensation)
Storage temperature:
-20 to +70 ° C
Thermal stability:
20 ppm / ° C
Temperature drift:
0.005% FS / ° C
Zero Calibration:
Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Calibration of full scale (fs):
Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Analog filter (for V output only):
Adjustable through trimmer monoturn 270 ° C
Mounting:
DIN rail
Dimensions:
133 x 92 x 56 mm (L x H x D)
Connections:
Screw terminal blocks 5.08 mm pitch
CE conformity:
EN50081-1, EN5002-2 EMC, LVD EN61010-1
Options:
Power supply 115 or 230 VAC 50/60 Hz (for DIN rail)