Encoder supply: |
5 V (max 6 350 ohm cells) |
|
Measuring range: |
-0.5 to +3.5 mV / V (optional from -3.9 to +3.9 mV / V) |
|
input sensitivity: |
00:02 microV / Division |
|
Linearity: |
<0.01% of full scale |
|
Temperature drift: |
<0.001% FS / ° C |
|
Display: |
6 digits, red 7-segment LED, height 14 mm |
|
A / D converter: |
24-bit |
|
Internal resolution: |
> 16,000,000 points |
|
viewable resolution: |
60,000 displayable divisions on the net weight |
|
divisions value (selectable): |
x1, x2, x5 |
|
settable decimal: |
0.0; 0.00; 0.000 |
|
Filter: |
selectable from 0.1 to 25 Hz |
|
Power tool: |
24 VDC ± 15% - Power consumption 5 W |
|
Operating temperature: |
-10 To + 50 ° C (max 85% humidity non-condensing) |
|
Storage temperature: |
-20 To + 70 ° C |
|
logic outputs: |
2 optisolate; MAX 24 VDC / 100 mA each. |
|
Logic inputs: |
2 opto-isolated 24V dc PNP (external power supply) |
|
Serial port: |
RS232C with ASCII or Modbus RTU protocols |
|
Transmission distance: |
15m (RS232C) |
|
fieldbus protocol: |
PROFINET |
|
Peak Hold function: |
for dynamic measurements |
|
Baud rate: |
2400, 9600, 19200, 38400, 115200 Selectable |
|
Regulatory Compliance: |
EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety |
|
Electric connections: |
Terminal screw, step 5 mm |
|
Dimensions and weight: |
96 x 48 x 120 mm (W x H x D); 250 g |