Encoder supply: |
5 V (max 6 350 ohm cells) |
|
Measuring range: |
÷ -0.5 +3.5 mV / V (optional ÷ -3.9 +3.9 mV / V) |
|
input sensitivity: |
00:02 microV / Division |
|
Linearity: |
<0.001% FS / ° C |
|
Temperature drift: |
<0.001% FS / ° C |
|
Display: |
6 digits, red 7-segment LED, height 14 mm |
|
A / D converter: |
24-bit |
|
Internal resolution: |
> 16,000,000 points |
|
viewable resolution: |
60,000 displayable divisions on the net weight |
|
settable decimal: |
0.0; 0.00; 0,000 |
|
Filter: |
selectable from 0.1 to 25 Hz |
|
Keyboard: |
4 keys tactile feedback disabled if |
|
Power tool: |
18 ÷ 28 VDC - Power consumption 5 W |
|
Operating temperature: |
-10 To + 50 ° C (max 85% humidity non-condensing) |
|
Storage temperature: |
-20 To + 70 ° C |
|
logic outputs: |
2 opto-isolated; MAX 24 VDC / 100 mA each |
|
Logic inputs: |
2 opto-isolated 24V dc PNP (external power supply) |
|
Serial port: |
USB, RS232C or RS422 / RS485 with Modbus RTU or ASCII protocols |
|
Transmission distance: |
15m (RS232C), 1000m (RS422 and RS485) |
|
fieldbus protocol: |
PROFIBUS, DEVICENET, ETHERNET, PROFINET (optional) |
|
Communication with other fieldbus: |
CANopen, Modbus-Plus and others; Precise Gateway 3000 (optional) |
|
Peak Hold function: |
for dynamic measurements |
|
Baud rate: |
2400, 9600, 19200, 38400, 115200 Selectable |
|
Optional analog output: |
optically isolated 16 Bit Voltage: 0 to 5 / 10V (R min10 K Ohm) Current: 0/4 to 20mA (R max 300 Ohm) |
|
Regulatory Compliance: |
EN50081-1, EN50082-2 for EMC; EN61010-1 for Electrical Safety |
|
Electric connections: |
Terminal screw, step 5 mm and 4 PG9 |
|
Dimensions and weight: |
215x210x105 (PBS) (WxHxD) |
|
Hole spacing (4): |
157x127 (PBS) (WxH) |