Recommended input: |
100 ÷ 240 Vca 50/60 Hz - 25 W |
Temperature range: |
-10°C ÷ +40°C |
Storage temperature: |
-20°C ÷ +50°C |
Display: |
5 alphanumeric digits of 5 x 7 LED red. LED Surface: 460 x 100 mm Available in a kit including 8-digit (LED surface 780 x 100 mm) |
Display brightness: |
Anti-glare filter and automatic brightness depending on ambient light, suitable for installation even in direct sunlight |
Visible data: |
Weight gained by load cells or analog input 0 to 10 V or 4 to 20 mA; alphanumeric indications and programming menu |
Radio control functions: |
Tare, zero balance, serial transmission current weight, configuration and calibration |
Dimensions: |
500 x 185 x 115 mm ( L x H x D ) |
Mounting: |
On wall with 4 side holes outside Ø 6.5 mm with 510 x 155 mm (W x H) |
Container: |
Stainless steel protect against dust |
Electrical connection: |
Sealed circular connectors, with wiring conductors with screw terminals |
Trasducer input voltage: |
5 V (max 8 load cells 350 Ohms) |
Linearity: |
<0.01% R.O. |
Thermic drift (Load cell): |
<0.0003% R.O./°C |
Thermic drift (Input): |
<0.001% R.O./°C |
Internal resolution: |
24 bit |
Visible resolution: |
> 60.000 divisions |
Measuring range: |
-1.5 ÷ +3.5 mV/V |
Acquisition frequency: |
6 ÷ 25 Hz |
Filter: |
0.2 Hz ÷ 25 Hz adjustable |
Set decimal: |
0 ÷ 3 decimal figures |
Serial door: |
RS232C / RS422 / RS485 |
Transmission distance: |
15m (RS232) e 1000m (RS422/RS485) |
Protocol: |
ASCII + Programmable custom protocols |
Baud rate: |
1200 ÷ 115200 adjustable |
Options: |
Ethernet and Profibus DP protocols |
Regulatory compliance: |