Trasducer input voltage: |
5 V (max 8 load cells 350 Ohm in parallel) |
Measuring range: |
-3.9 ÷ +3.9 mV/V |
Input sensitivity: |
0.02 µV/ per count |
Linearity: |
<0.01% of full scale |
Gain drift: |
<0.0003% full scale/ °C |
A/D Converter: |
24 bit |
Internal resolution: |
> 16.000.000 counts |
Visible resolution: |
600.000 divisions displayed on net weight |
Divisions value (adjustable): |
x1, x2, x5 |
Set decimal: |
0.0 ; 0.00 ; 0.000; 0.0000 |
Filter: |
0.2 ÷ 50 Hz. 100 Hz during dosage |
Tool voltage: |
230 Vac ±10% - 50/60 Hz absorbed power 7 VA (115 Vac on demand) |
Temperature range: |
-10 ÷ +50°C |
Storage temperature: |
-20 ÷ +70°C |
Logic output: |
6 relays (NA) MAX 115 Vac /30 Vdc 0.5 A cad. |
Logic input: |
8 optoisolated 12 / 24 Vdc PNP |
Serial door: |
COM1: RS232 half duplex COM2: RS422/RS485 half duplex |
Transmission distance: |
15m (RS232C), 1000m (RS422 and RS485) |
Protocol: |
ASCII, Modbus RTU |
Baud rate: |
1200 ÷ 115200 adjustable |
Regulatory compliance: |
EN45501 for Metrological Norms EN50081-1 and EN50082-2 EMC EN61010-1 for Electrical Safety |
Fiscal optional memory: |
> 160.000 weighed |
Power supply: |
12 to 24 VDC -10% to +15%, 15 VA |