Synchronized acquisition |
|||
|
|||
Practical exampleA company develops filling systems for the beverages industry. A measurement case was required to measure electrical power data in addition to standard signals and impulses. Simultaneous and synchronised measurement was required at 10 3-phased electrical measurement points of up to 1000 A, as well as flow measurements for gas and liquids, compressed air metering and temperature measurement. In addition, the electrical measurement points were to be capable of wireless connection via special measurement transducers. AC current measurement takes place using flexible Rogowski coils which avoid the need to disconnect conductor rails. The energy measurement case is used for servicing and acceptance-control measurement. In combination with the ProfiSignal software, it provides users with a universal and flexible tool. |
|||