SCIENCEGATE
Home
Products
Profile
About Us
Events
Career
Contacts
Contact Us
(65) 6561 0488
Overview
Main Features
Specifications
Product Reference
BND-AN-MV-XTD-
N
CH
N- Number of data acquisition channels :
-
4
: 4 Channels
Example : BND-AN-MV-XTD-
4
CH : BeanDevice
®
AN-mV Xtenderwith four channels
Analog data acquisition block specifications
Signal Conditionning
Analog low voltage mV
with voltage-compensated measurement
Number of channels
4 Channels
A/D Converter
16 bits - SAR Architecture (Successive Approximation Register) with temperature compensation
Measurement range
±20 mV (bipolar) or 0-40 mV (unipolar)
Non-linearity error
± 0,5 LSB
Measurement accuracy
< 0,2% when plugged on external power supply
< 0,4% when operating on battery
Sensor Connector
M12-5Pins coming with an IP rating IP67
Sensor wiring code (M12 Socket)
Caption
Pwr+ : sensor power supply (4.5 to 20 Volts)
Gnd : electrical ground
Sens+ : sensor signal + input
Sens- : Not used
Sensor Power Supply specifications
Excitation voltage range
4.5 Volts to 20Volts , configurable from the BeanScape
®
software
Excitation voltage accuracy on full scale range(@25°C)
±0.1%
Maximum Output Power (@25°C)
2 Watts
Over-the-air configuration (OTAC) parameters
Data Acquisition mode
Low Duty Cycle Data Acquisition (LDCDA) Mode: 1s to 24 hour
Alarm & Survey mode: 1s to 24 hour
Alarm Threshold
2 high levels alarms & 2 low levels alarms
Sensor power supply
4.5 to 20 Volts
Analog Input polarity
Bipolar or Unipolar
Power Mode
Sleeping, Sleeping with Network Listening & Active
TX Power
-7 dBm / -1 dBm / 5 dBm / 11 dBm / 15 dBm / 18 dBm
RF Specifications
Wireless Protocol Stack
IEEE 802.15.4 (2006 version)
WSN Topology
Point-to-Point / Star
Data rate
250 Kbits/s
RF Characteristics
ISM 2.4GHz – 16 Channels
TX Power
+0 dBm to +18 dBm
Receiver Sensitivity
-95,5 dBm to -104 dBm
Maximum Radio Range
1 Km (L.O.S)
Antenna diversity
2 omnidirectional N-Type antenna , gain of 2.2 dBi , IP67
Embedded Data logger
Storage capacity
up to 1 million data points
Wireless data downloading
3 minutes to download the full memory (average time)
Environmental and Mechanical
Enclosure
Aluminium, Watertight IP65 – Fire Protection : ULV94/Getex
Enclosure dimensions (w/o antenna ) L x l x h : 149.1mm x 77mm x 60.5mm
Weight : 690g
Shocks resistance
10g during 50 ms
Operating Temperature
-40 °C to +85 °C
Norms
CE Labelling Directive R&TTE (Radio) ETSI EN 300 328
ROHS - Directive 2002/95/EC
Power supply
Primary cell protection
Integrated Lithium-ion battery charger with high precision battery monitoring :
Overvoltage Protection, Overcurrent/Short-Circuit Protection, Undervoltage Protection
Battery Temperature monitioring
Current accumulation measurement
Current consumption @3.3V
During data acquisition : 70mA to 130mA (depends on external sensor power supply)
During Radio transmission : 60 mA @ 0dBm
During sleeping: < 30 µA
Primary cell
External power supply : +8v to +28v
Rechargeable battery
Lithium-Ion high density rechargeable battery capacity of 950 mAh
Option(s)
Calibration certificate
Calibration certificate linked to national and international standards (COFRAC)
Please register here in order to access the download page.