*1 There are some restrictions regarding replacement with recommended substitutes.
Recommended Substitute
Model in use
Comments
PFXSP5B40
SP5000 Series
Open Box
Recommended Substitutes
Comments
Details
PFXSP5B41
SP5000 Series
New Open Box
SP5000 series / What's the difference between Open Box SP-5B40 and SP-5B41? How can I replace SP-5B40 with SP-5B41?
The differences between the old Open Box, SP-5B40 and the new Open Box, SP-5B41 are as follows;
For details, refer to SP5000 series hardware manual and reference manual.
Old Open Box
SP-5B40
New Open Box
SP-5B41
CPU
Atom E6x0 1.3GHz
(Single Core / Dual thread)
Atom E3825 1.33GHz
(Dual Core / Dual thread)
L2 Cache Memory
512KB
1MB
Main Memory
DDR2 SDRAM 2GB
DDR3L SDRAM 2GB
Video Memory
64MB max (UMA main memory)
256MB max (UMA main memory)
System Card
CFast card : 16GB
Free space : Approx. 5GB
CFast card : 32GB
Free space : Approx. 17GB
User Storage
CFast card x 1 SD card (SD, SDHC) x 1
CFast card x 1
SD card (SD, SDHC, SDXC) x 1
OS
WES7 SP1
Serial
RS-232C/422/485 x 2
USB
USB2.0 (Type A) x 3
USB2.0 (mini-B) x 1
Ethernet
10BASE-T/100BASETX/1000BASE-T x 2
Expansion Unit
Field Bus Unit x 1
Video
DVI-D out x 1 (VGA/SVGA/XGA)
DVI-D out x 1
(Up to WUXGA)
Power consumption
35W
25W
External dimensions
188(W) x 131(H) x 35(D) mm (7.4 x 5.16 x 1.38 in)
■Replacement Procedures
The OS image (System Card) for SP-5B40 cannot be used for SP-5B41. Create a new OS image (System Card).
Transfer the HMI screen data to the new Open Box, SP-5B41 on GP-Pro EX.
Install on the new Open Box, SP-5B41 all the applications used on the old Open Box, SP-5B40 and then transfer necessary data.
After transferring data to SP-5B41 is completed, create an OS image (System Card) with [Backup & Recovery Tool], and save it as backup data.
Important note
When inserting the system card of the old Open Box, SP-5B40 into the new Open Box, SP-5B41, the screen gets dark after startup of Windows.
When inserting the system card of the new Open Box, SP-5B41 into the old Open Box, SP-5B40, every driver is updated after startup of Windows.
PFXGP4603TAD
*1Other font sizes can be set up with the Editor software.
*2Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
*3
The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit's level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
*4
For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.
PFXGP4601TMD
*1Other font sizes can be set up with the Editor software.
*2Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
*3
The front face of this product, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.
*4
For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.