Fine wire counterpart (Measurement object diameter: Φ 0.02 to 3 mm, 0.02 to 5 mm)
Model No.
TM-503W
TM-1100XY
TM-1003W
TM-1104W
CAD file
Power supply unit (PW-02)
[*1]
Power supply unit (PW-01)
[*1]
Power supply unit (PW-02)
[*1]
Power supply unit (PW-01)
[*1]
Direction of detection
3 directions
2 directions
3 directions
4 directions
Measurement method
Double slit infrared LED projection type
Adaptive work outer diameter
φ0.02 to 3 mm
φ0.02 to 10 mm
φ0.02 to 5 mm
φ0.02 to 10 mm
Unevenness detection range
0.02 to 1 mm
Unevenness detection accuracy
Maximum setting within ± 1%
Slit length
6 mm
18 mm
12 mm
18 mm
Slit width
0.1 mm
0.5 mm
Linear speed [*1]
5 m / min to 2000 m / min
1 m / min to 1500 m / min
Recorder output
± 0.2 V / 0.1 mm
± 1 V / 0.1 mm
± 0.5 V / 0.1 mm
± 1 V / 0.1 mm
Alarm output
Uneven red LED lit, Relay contact output (AC 250 V 2A resistive load)
Alarm time [*2]
0.1 seconds
0.5 seconds
0.1 seconds
0.5 seconds
Operating temperature
-5 to 50 ° C (without condensation)
Power supply [*3]
DC ± 15 V
AC 100V
50/60 Hz
DC ± 15 V
AC 100V
50/60 Hz
Power consumption
6VA
10VA
6VA
10VA
Outline Dimensions (mm)
150 × 140 × 40
260 × 265 × 60
150 × 140 × 40
350 × 280 × 55
Weight
0.8kg
2.5kg
1kg
5kg
[*1] PW-01 is a power supply dedicated to TM-1003W.PW-02 is a power supply for both TM-503W and TM-1003W.
(The enclosures are the same size for PW-01 and PW-02.)
[*2] Applicable line speed range changes depending on the hight of lump.
[*3] Alarm output can be hold by option
[*4] AC200V power supply specification is also available as an option.
Medium wire counterpart (Measurement object diameter: Φ 0.1 to 35 mm)
Uneven red LED lit, Relay contact output (AC 250 V 2A resistive load)
Alarm time [*2]
0.5 seconds
Operating temperature
-5 to 50 ° C (without condensation)
Power supply [*3]
AC 100 V 50/60 Hz
Power consumption
5VA
10VA
10VA
20VA
40VA
Outer dimension
260 × 90 × 41 [mm]
260 × 260 × 60 [mm]
370 × 355 × 60 [mm]
370 × 355 × 120 [mm]
370 × 355 × 240 [mm]
Weight
1.5kg
3kg
6kg
12kg
24kg
[*1] Applicable line speed range changes depending on the hight of lump.
[*2] Alarm output can be hold by option
[*3] AC200V power supply specification is also available as an option.
Alarm red LED on, Relay contact output (AC250V 2A resistive load)
LED lighting (concave: yellow / convex: red), relay contact output (AC 250 V 2A resistive load unevenness output separately)
Alarm time [*2]
0.5 seconds
Operating temperature
-5 to 50 ° C (without condensation)
Power supply [*3]
AC 100 V 50/60 Hz
Power consumption
10VA
20VA
30VA
60VA
120VA
Outer dimension
450 * 120
× 50 [mm]
640 * 560
× 160 [mm]
807 * 674
× 136 [mm]
807 * 674
× 272 [mm]
807 × 680
× 424 [mm]
Weight
3kg
25kg
38kg
76kg
152kg
[*1] Applicable line speed range changes depending on the hight of lump.
[*2] Alarm output can be hold by option
[*3] AC200V power supply specification is also available as an option.
Applicabe to extra thick wire (Measurement object diameter: Φ 1 mm to 80 mm, 1 to 130 mm)
Model No.
TM-6004A
TM-6008
(TM-6004A)
(TM-6004B)
TM-7003A
TM-7009
(TM-7003A)
(TM-7003B)
(TM-7003C)
CAD file
Direction of detection
4 directions
8 direction
3 directions
9 direction
Measurement method
Single slit white tungsten lamp floodlight type
Adaptive work outer diameter
φ 1 to 80 mm
φ1 to 130 mm
Unevenness detection range
0.2 to 10 mm
Unevenness detection accuracy
Maximum setting value within ± 2%
Slit length
95 mm
135 mm
Slit width
1.5 mm
Linear speed [*1]
0.3 m / min to 500 m / min
Recorder output
± 0.1 V / 0.1 mm (for each axis)
Alarm output
LED lighting (concave: yellow / convex: red), relay contact output (AC 250 V 2A resistive load unevenness output separately)
Alarm time [*2]
0.5 seconds
Operating temperature
-5 to 50 ° C (without condensation)
Power supply [*3]
AC 100 V 50/60 Hz
Power consumption
30VA
60VA
30VA
90VA
概略外寸
720 x 660
× 153 [mm]
720 × 660
× 306 [mm]
990 × 930
× 125 [mm]
990 × 930
× 375 [mm]
Weight
38kg
76kg
60kg
180kg
[*1] Applicable line speed range changes depending on the hight of lump.
[*2] Alarm output can be hold by option
[*3] AC200V power supply specification is also available as an option.
In addition to this, you can also prepare products such as TM-6020 (20 axis) and other multi-axis products.
Gauge Fixture / Calibration gauge unit for Surface Variation Detector
Calibration gauge unit
Gauge outer diameter (mm)
Model
Accuracy
Φ1.0
TMG-10
±1μm
Φ0.5
TMG-05
±1μm
Note) It can be available down to Φ0.1.
Gauge Fixture and corresponding gauge unit table
Target Model
Calibration gauge to use
Mounting jig type
TM-1000S
TMG-05
01
TM-1003
TMG-05
02
TM-1000XY
TMG-05
03
TM-1004
TMG-05
04
TM-1100XY
TMG-05
05B
TM-1003W
TMG-05
06B
TM-1104W/TMS-1104W
TMG-05
07B
TM-503W
TMG-01
16B
TM-3001W
TMG-10
08B
TM-3002W
TMG-10
09
TM-3004W
TMG-10
10B
TM-3008W
TMG-10
10B
TM-3016W
TMG-10
10B
TM-4001/4001W
TMG-10
----
TM-4002
TMG-10
12B
TM-4002W
TMG-10
17B
TM-4004
TMG-10
13B
TM-4008
TMG-10
13B
TM-4016
TMG-10
13B
TM-6004
TMG-10
14B
TM-6008
TMG-10
14B
TM-6016
TMG-10
14B
TM-7003
TMG-10
15B
TM-7009
TMG-10
15B
Example of calibration method (TM-3004W)
Although our detectors are calibrated at the time of shipment, when it is necessary to perform calibration for checking the sensitivity at the time of inspection etc., please perform calibration according to the following method with the calibration gauge unit. The calibration gauge unit to be used is "TMG - 10, Gauge Fixture 10B".
** Before calibration, please be sure to clean the glass filter of the projecting / receiving part and warm up for 10 minutes.
I will explain with 1 axis as an example.
Set the Gauge Fixture according to the axis for calibration (this time, 1 axis). (The figure below)
Set the level setting dial to "1.00".
Insert the gauge tip quickly into the center of the measuring range. At this time, please insert gauge so as not to be inclined as much as possible.
When the gauge tip is inserted while repeating the insertion several times, adjust the gain setting VR of 1 axis the lowest to light up the detection alarm lamp.(herein after lamp)
* It is not abnormal although the lamp may light up when extracting the tip of the gauge.
* Set an interval of about 3 seconds after the lamp is turned off when repeating the insertion of the gauge tip.
* VR for gain setting increases sensitivity when turned clockwise, and decreases when turning it counterclockwise.
Change the level setting dial to "1.03".
Repeat the insertion of the gauge tip in the same way.Now adjust the VR for 1 axis gain adjustment so that the lamp does not light up when inserting the tip of the gauge.
The calibration will be completed after repeating steps (2) - (6) several times to light up at "1.00" and not light up at "1.03".
For Thin Wire
Outer dimension[W * H * D] 150×140×40(mm) TM-503W
Outer dimension[W * H * D] 260×265×60(mm) TM-1100XY
Outer dimension[W * H * D] 150×140×40(mm) TM-1003W
Outer dimension[W * H * D] 350×280×55(mm) TM-1104W
For Medium Wire
Outer dimension[W * H * D] 260×90×41(mm) TM-3001W
Outer dimension[W * H * D] 260×260×60(mm) TM-3002W
Outer dimension[W * H * D] 370×335×60(mm) TM-3004WA
TM-3008W
TM-3016W
For Thick Wire
Outer dimension[W * H * D] 540×160×100(mm) TM-4001
Outer dimension[W * H * D] 630×560×160(mm) TM-4002
Outer dimension[W * H * D] 807×674×136(mm) TM-4004
TM-4008
TM-4016
Applicabe to extra thick wire
Outer dimension[W * H * D] 720×660×153(mm) TM-6004A