Digitax HD M754 MCi

Servo drive and controller in one

powerful MCi second processor onboard the Digitax M754 servo drive brings a whole host of machine design opportunities.

The onboard MCi processor executes comprehensive programs that can control multiple drives and motors simultaneously across real-time networks

Onboard Ethernet using RTMoE (Real Time Motion over Ethernet) provides synchronization and communication between drives using the Precision Time Protocol (PTP) as defined by IEEE1588 V2 

Simple integration with external components such as Remote I/O, HMIs and PLCs can be achieved with Modbus TCP/IP on the integrated 2-port standard Ethernet switch.

 
  • Functional Safetyfunctional-safety

    All Unidrive M drives have integrated dual Safe Torque Off (STO) inputs, certified to SIL3 / PLe, providing an elegant and reliable safety solution. 
    The addition of an MiS210 safety option extends the built-in STO with the ability to safely monitor and/or restrict the scope of motion. 
    Safety functions include: STO, SBC, SOS, SS1, SS2, SLS, SSM, SLA, SDI, SLP & SES
    For maximum flexibility in the safety system architecture, the modules support both wired and network safety connections: CIP-Safety on EtherNet/IP and Safety over EtherCAT (FSoE).
    To find out more, visit our Functional Safety page.

 
 
Approval & Listings

cUL

USA and Canada (cUL Listed). UL File number: E171230

CE

European Union (all applicable directives and regulations LVD, EMD, RoHS, REACH, Energy related products)

UKCA

United Kingdom (all applicable regulations)

RCM

Australia and New Zealand (Responsible Supplier Registration No. E6934)

EAC

Russian Customs Union. All Digitax HD models

KC
South Korea
Certificate Nos:

R-R-461-M751-03400160A
R-R-461-M751-01400042A
R-R-461-M751-012400105A

Functional Safety

Safe Torque Off function.

TÜV Rheinland Type Examination Certificates:
01/205/5270.02/17 (Unidrive-M and derivative products)
01/205/5409.02/21 (SI-Safety  option module)
01/205/5720.00/19 (MiS210, MiS250 option modules)

The safety function "Safe Torque Off" can be used in applications up to Cat 4. PL e according to EN ISO 13849-1, SIL 3 according to EN 61800-5-2/ EN 62061/ IEC 61508, and in lift applications according to EN 81-1 and EN81-2.

UL Functional Safety

Unidrive-M all products
File E171230     Vol. 11  Sec. 1 Issued:  2015-01-22
Compliance with specific requirements of NFPA 79 

Functional Safety
for Elevators

TÜV Nord certificates:
44 799 17002402 (Frequency converters with Safe Torque Off function for lift drives)

ISO

Quality system: ISO 9001 (Certificate Nos. FM 739405)
Environmental management system: ISO 14001 (Certificate No. EMS 739789)
Occupational health and safety: ISO 45001 (Certificate No. 5430)

China RoHS

Chinese Order No. 32, 2016; Administrative Measures for the Restriction of Hazardous Substances in Electrical and Electronic Equipment (China RoHS 2),

EPA TSCA regulations

All Commander and Uni-M products
U.S. Environmental Protection Agency (“EPA”) recently promulgated regulations under the Toxic Substances Control Act (“TSCA”)

IHM, Basel convention,

MEPC 68/21 / Add.1, Annex 17, Resolution MEPC.269(68) 2015 Guidelines for the development of the inventory of hazardous materials.

Responsible Minerals Initiative (RMI)

CMRT compliance

 
 

 


Please register here in order to access the download page.
Name: *
Email address: *
Company Name: *
Designation: *
Contact No: *
 
  * Please filled in the required details.