Switch-Pak™ AX1X with Compact Junction Box
|
|
|
|
 |
 |
 |
 |
 |
Series |
LU10 |
LZ12 |
LP15 |
LV10 |
LO10 |
Type |
Ultrasonic switch |
Vibration switch |
Capacitance switch |
Buoyancy switch |
Optic switch |
Classification |
Intrinsically safe |
General purpose |
General purpose |
General purpose |
General purpose |
Application |
Chemical or light weight oil |
Wastewater |
Conductive coating chemical |
Water or chemical |
Secondary containment |
Installation |
Universal |
Universal |
Side wall |
Top wall |
Universal |
Function |
Level switch |
Level switch |
Level switch |
Level switch |
Leak detection |
Max. length |
— |
— |
— |
— |
— |
Supply |
12-36 VDC |
12-36 VDC |
12-36 VDC |
— |
12-36 VDC |
Contact |
(1) SPST relay |
(1) SPST relay |
(1) SPST relay |
(1) SPST reed |
(1) SPST relay |
Rating |
32 VDC (0.5A max) |
60 VA (1A max) |
60 VA (1A max) |
15 VA (0.25A max) |
60 VA (1A max) |
Enclosure |
NEMA 6 (IP68) |
NEMA 6 (IP68) |
NEMA 6 (IP68) |
NEMA 6 (IP68) |
NEMA 6 (IP68) |
Termination |
Cable |
Cable |
Cable |
Cable |
Cable |
Mount |
3/4″ NPT (G) |
3/4″ NPT (G) |
3/4″ NPT (G) |
3/4″ NPT (Rp) |
3/4″ NPT (G) |
Temperature |
-40º F. (-40º C.) to 176º F. (80º C.) |
-40º F. (-40º C.) to 176º F. (80º C.) |
-40º F. (-40º C.) to 176º F. (80º C.) |
-40º F. (-40º C.) to 176º F. (80º C.) |
-40º F. (-40º C.) to 176º F. (80º C.) |
Max. pressure |
150 PSI (10 bar) |
150 PSI (10 bar) |
150 PSI (10 bar) |
25 PSI (10 bar) |
150 PSI (10 bar) |
Material |
PP / PFA |
PP-Ryton |
PP |
PP / PVDF |
PP / PFA |
|
|
Application
The intrinsically safe or general purpose level switch package provides high or low liquid level detection with one relay or reed switch output, and a compact junction box for wiring termination. Available in three level sensor technologies, choose the sensor type based upon your application media and classification. This PP or PVDF level switch package is selected for bulk storage, IBC or drum, and neutralization tank applications, connected to a PLC or relay controller.
|
|
Features
Rugged PP or PVDF construction for use with corrosive liquids
Available in intrinsically safe and general purpose classifications
60VA relay or 15VA dry contact switches selectable NO or NC via wiring
Offered in three sensing technologies for broad application coverage
PP enclosure rated NEMA 4X with swivel base for conduit alignment
|
|
Specifications
Length: |
6" to 10' (15cm to 3m) |
Accuracy: |
± 1mm in water |
Repeatability: |
± 0.5mm in water |
Orientation: |
± 20º vertical |
Switch points: |
1 (factory set) |
Supply voltage: |
AV16: N/A
AU18: 12-36 VDC
AZ18: 12-30 VDC |
Consumption: |
AV16: N/A
AU18 / AZ18: 25 mA max. |
Contact type: |
AV16: (1) SPDT reed
AU18 / AZ18: (1) SPST relay |
Contact rating: |
AV16: 15 VA, 0.25A max.
AU18 / AZ18: 60 VA, 1A max. |
Contact output: |
Selectable NO / NC |
Process temp.: |
F: -40° to 176°
C: -40° to 80° |
Ambient temp.: |
F: -40° to 140°
C: -40° to 60° |
Installed height: |
3.6” (9.1cm) above tank process mount |
Pressure: |
AV16: 25 psi (1.7 bar)
AU18 / AZ18: 150 psi (10 bar) |
Enclosure rating: |
NEMA 4X (IP65) |
Enclosure mat.: |
PP, UL94VO |
Terminal strip: |
6-pole, socket |
Conduit entrance: |
1/2" NPT |
Wetted material: |
AV16-224X: PP
AU18-224X: PP
AU18-524X: PVDF
AZ18-424X: PP-Ryton® |
Process mount: |
-X243: 2" NPT
-X247: 1 1/2" G |
Classification: |
AV16 / AZ18: general purpose, AU18: intrinsically safe (see LU10 data sheet for details) |
Compliance: |
CE |
|
|
|