Contact Us (65) 6561 0488

PFXZCETWW1

 

Standard product information
Family 
Peripheral Equipment
Series 
EZ Series
Size 
Tower Light
Model 
PFXZCETWW1
Global Code 
PFXZCETWW1
Product Features 
USB2.0 (Powered from USB bus), with base mounting
Sales Status 
Sale
Repair Status 
- (Maintenance service is not available. Replace with a new unit.)
 
Specifications

System Configuration

system_config_tower.jpg
 

*1USB cable not included. Optional Pro-face cable (model: ZC9USCBMB1) or commercially available product must be purchased.

*2In case of connect with GP4000M, need external power supply for USB port

*3Software version varies according to models connected with EZ Tower Light.

General Specifications

Product Name EZ Tower Light
tube mounting
with fixing plate
(PFXZCETWHA1)
EZ Tower Light
with base mounting
(PFXZCETWW1)
Units 3
Color Red / Green / Blue / Yellow
Light Mode Off / On / Blink (High) / Blink (Low)
Buzzer 4 sounds
Buzzer Volume High / Middle / Low
Buzzer Tone High / Low
Buzzer 85dB 82dB
Interface USB 2.0 (Mini B)
Supply Voltage DC 5V (Powered from USB bus)
Power Consumption 2W
Surrounding Air Operating Temperature 0 to 55 ℃ (32 to 131 ℉)
Operating Humidity 35 to 85%RH (no condensation)
Operating Atmosphere No Corrosive Gas
Storage Temp. -35 to 70 ℃ (-95 to 158 ℉)
Protection IP54
Weight 0.3kg (0.66lb)
Safety Standard UL508    CE marking

Dimensions

towerlight_ext_demen.jpg
 
 

 

PFXZCETWHA1

 

Standard product information
Family 
Peripheral Equipment
Series 
EZ Series
Size 
Tower Light
Model 
PFXZCETWHA1
Global Code 
PFXZCETWHA1
Product Features 
USB2.0 (Powered from USB bus), tube mounting with fixing plate
Sales Status 
Sale
Repair Status 
- (Maintenance service is not available. Replace with a new unit.)
 
Specifications

System Configuration

system_config_tower.jpg
 

*1USB cable not included. Optional Pro-face cable (model: ZC9USCBMB1) or commercially available product must be purchased.

*2In case of connect with GP4000M, need external power supply for USB port

*3Software version varies according to models connected with EZ Tower Light.

General Specifications

Product Name EZ Tower Light
tube mounting
with fixing plate
(PFXZCETWHA1)
EZ Tower Light
with base mounting
(PFXZCETWW1)
Units 3
Color Red / Green / Blue / Yellow
Light Mode Off / On / Blink (High) / Blink (Low)
Buzzer 4 sounds
Buzzer Volume High / Middle / Low
Buzzer Tone High / Low
Buzzer 85dB 82dB
Interface USB 2.0 (Mini B)
Supply Voltage DC 5V (Powered from USB bus)
Power Consumption 2W
Surrounding Air Operating Temperature 0 to 55 ℃ (32 to 131 ℉)
Operating Humidity 35 to 85%RH (no condensation)
Operating Atmosphere No Corrosive Gas
Storage Temp. -35 to 70 ℃ (-95 to 158 ℉)
Protection IP54
Weight 0.3kg (0.66lb)
Safety Standard UL508    CE marking

Dimensions

towerlight_ext_demen.jpg
 
 

 

 

EZ LAN Adapter for simply networking the current machines/facilities, Dual IP would be standard in Pro-face HMI

IoT has been recently promoted in Automation, but they are facing a wide range of challenges. For example, when pushing forward networking of existing facilities, end user or machine builder need to adapt the changes to the facilities, and considering to add Ethernet switches for managing mass IP addresses. It requires time and cost, therefore, the networking often have been ended up giving up.

To solve such concerns, "EZ LAN adapter" that allows you to easily achieve networking by adding it will be released. This product is a USB-Ethernet converting adapter for GP4000 Series and allows you to easily add an additional Ethernet interface (RJ-45) to HMI. That promotes networking using the existing system and reduce workload for networking and managing IP address.

Since this is an optional product, end users just attach it to the existing GP4000 Series and equipment manufacturers can add it for only the customers who need it. It’s possible to easily start IoT.

Product Features

Divide Network Layer

  • Enable to divide IT network from Control network
  • Total two Ethernet interfaces on HMI (Two individual IP address)
  • Reduce workload for networking and managing IP address

Retrofit, Easily adapt existing machine/facility installed GP4000 Series

  • Thanks to the EZ Series concept (Optional USB connection), you can easily add Ethernet port

Configure by only HMI

  • No need to configure it by PC with software. It is easy for END user to add it.
 
 

 

 
  • Series
  • Operating Environment
  • Software
  • Downloads
 

Pro-face Connect Restrictions

Drivers that support ladder monitor tools and device/PLC communication

Drivers that have been evaluated to support the Pass-Through Function in the Pro-face Connect environment. This information is updated as other drivers are evaluated.
 

Drivers that can communicate with Pass-Through Function

Device/PLC Manufacturer Driver Name Series Name
Mitsubishi Electric Corporation Q Series CPU Direct MELSEC Q
QnA Series CPU Direct MELSEC QnA
QUTE Series CPU Direct MELSEC Q
FX Series CPU Direct MELSEC FX
Yaskawa Electric Corporation MP Series SIO (Extended) MP2000
MP Ethernet/Mechatrolink MP2000
Yokogawa Electric Corporation Personal Computer link SIO FA-M3
Personal Computer link Ethernet FA-M3
Omron Corporation CS/CJ Series HOST Link CJ1
CS/CJ Series Ethernet CJ1
Rockwell Automation, Inc. DF1 CompactLogix
Siemens AG SIMATIC S7 MPI Direct SIMATIC S7-300
KEYENCE Corporation KV-700/1000/3000/5000 CPU Direct KV-1000
Panasonic Industrial Devices SUNX Co., Ltd. FP Series Computer Link SIO FP
Shibaura Machine CO., LTD. TC Series (TCmini/TC200) TCmini

Drivers that can communicate with device/PLC set up as SiteManager Agents

This connection is possible when the license format is SiteManager Embedded Extended.

Device/PLC Manufacturer Driver Name Series Name
Mitsubishi Electric Corporation Q/QnA Series Ethernet MELSEC iQ-R
MELSEC iQ-F
MELSEC Q
Omron Corporation CS/CJ Series Ethernet CJ1
CJ2
KEYENCE Corporation KV-700/1000/3000/5000 Ethernet KV-5000
Siemens AG SIMATIC S7 Ethernet SIMATIC S7-200

Drivers that cannot communicate

Device/PLC Manufacturer Driver Name Series Name
Mitsubishi Electric Corporation Q Series QnU CPU Ethernet MELSEC Q

Actions you can use on Pro-Server EX

You can use the following actions only. *1
 
  • Upload to the database
  • Download from the database
  • Automatic Upload of Access Data
  • Automatic Download of Access Data
  • Writes Data to Excel Book
  • Download of Excel Recipe
  • Writes Data from CSV file
  • Writes Data to CSV file
  • Process-Data-Collection ACTION
  • Actual-Data-Collection ACTION
  • GP SRAM Alarm-History-File Collection ACTION
  • GP SRAM Sampling-Data Collection ACTION
  • ECreating a Report using Excel *2
  • Automatic Upload of GP Filing Data *2
  • Automatic Download of GP Filing Data *2
  • GP Log Data Upload *2
 

*1You cannot use actions where SiteManager or its agents are the trigger source (trigger conditions, entry nodes).

*2You cannot use data saved in external storage with this function. Save data to the display unit's internal memory.

 
 

 

 
  • Series
  • Operating Environment
  • Software
  • Downloads
 

Pro-face Connect Support / Download

Catalog

  • Product Guide
 
 

 

  1. Proface | Pro-face Connect | Software
  2. Proface | Pro-face Connect | Operating Environment
  3. Proface | Remote HMI | PFXEXRHSLS
  4. Proface | Remote HMI | PFXEXRHANDTRV**

Page 17 of 126

  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • Takikawa
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2025. ALL RIGHTS RESERVED.