    IDS/ID-Series Joint Detector/Wire-Breaking Detector
    • IDS Series are most recommended as a Joint detector, but ID Series (Low cost type) are also available for several applications.
    • IDS/ID Series are also available for detection of wire-breaking. CDD-15 is availble for detection of extra fine wire-breaking.
    •  
    Joint Specifications
     
     Method Proximity type
    induction voltage
    sensing
    Through type
    eddy-current loss
    sensing
    Through type
    eddy-current
    loss sensing by
    bridge circuit
    [High sensitivity] 
    Through type
    eddy-current
    loss sensing by
    bridge circuit
     Model [S] ID-3L ID-5 ID-8 ID-15 ID-30 ID-50 ID-90 IDS-24 IDS-60 IDS-100 IDX-06
    [C] ID-1001 IDS-501 IDX-701
     [S]Outside dimension
     [mm]
    W 30 22 30 38 50 70 110 74 150 201 66
    H 30 52 65 80 90 125 175 53.2 113.2 160 47.2
    D 22 7 8 10 10 25 38 76 120 124 51
     Through hole dia.(mm) (Distance:15) 5 8 15 25.5 50 90 24 60 100 6
     [C]Outside dimension
     (W * H * D[mm])
    120 * 100 * 55 150 * 120 * 75 160 * 150 * 90 140 * 137 * 101
     Power supply AC100V 50/60Hz AC100/200V 50/60Hz (With power on monitor)
     Power  consumption 2VA 3VA 5VA Less than 12VA
     Detectiong  output Red LED on, One-shot 1a-contact(0.5sec)
     Signal monitor Non Bargraph LED display
     Sensitivity adjustment Single turn volume 10 turns dial 10 truns dial
    & 5 step switch
    10 truns dial
    & vibration of wire correction
     Ambient  condition Temperature: 0 - 50 degree centigrade, Humidity:35 - 85%RH(No condensation)
     Feature * For less than
    10mm dia. objects
    * For magnetic
    substance
    * Not available for
    copper material
    * Not available for
    shielded cable
    * Necessary
    attention to
    sensing area
    * Abundant sensor variations
    * Available for all metal material
    * Available for torsion & alloyed junction
    * Not recommendable to shielded cable
    * Necesssary attention to vibration of wire
    * Available for metal material
    (Magnetic substance)
    * Available for 
     torsion & alloyed junction
    * Also available for 
     shieled cable
    * Not so necessary attention to small vibration of wire
    * Available for all metal material
    * Available for torsion & alloyed junction
    * Also available for shieled cable
    * Not so necessary     attention to small vibration of wire

     

    [S]: Sensor

    [C]: Controller
     
    Joint detectors are also used for wire-breaking detection. CDD-15 is applicable for extra fine wire-breaking detection. The following table shows a comparison between ID-1001/ID-15 and CDD-15.*take note under 15mm breaking length.
     Type CDD-15
     Method Through type capacitance sensing
     Sesor outside dimension (W * H * D[mm]) 52 * 49 * 30
     Controller outside dimension (W * H * D[mm]) 97 * 131 * 50
     Through hole dia. 15mm
     Power supply AC100/200V 50/60Hz 4VA
     Power on monitor NG
     Detecting object Only for single conductor wire,
    More than 0.75mm2 area,
    For more than 0.165mm as Covered cable dia.
     Detecting output Red LED on, One-shot 1a-contact(0.5sec)
     Signal monitor Non
     Sensitivity adjustment Non
     Ambient Temperature 1 - 70 degree centigrage
     Feature * Only for Extra fine single conductor wire
    * Not so necessary attention to small vibration of wire