T7M Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : T7M Series

Type : Electronic Multipoint Temperature Transmitter

Application : To measure mulit-point temperature

Typology : Temperature

Measure principle : Thermoresistive

Measuring range : 0~250 g/l, 0~3000 g/l

Supply : 12.5~30 VDC

Output : 4~20 mA + HART

Process connection : 6" ANSI 150, 1-1/2" G-M, 2" G-M

Process temperature : -40~85°C

Working presssure : Max 10 bar

Ingress protection degree: ANSI 316 housing : IP67, aluminum housing : IP66

ATEX Approval : Yes

 

OMD Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : OMD Series

Type : Oil Mist Detector

Application : To detect the oil mist for marine and industrial,in machinery room, pump room, in commercial, naval, ro-ro ships.

Typology : Oil Mist

Measure principle : Optical

Measuring range : 0~2 mg/l

Supply : 12.5~30 VDC

Output : 4~20 mA + HART

Photorelays : 3 photorelays (alarm, pre-alarm, fault)

Process connection : NA

Process temperature : -20~70°C

Working presssure : Max 10 bar

ATEX Approval : No

 

T72 Pressure Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : T72 Series

Type : SMART level,pressure and vacuum transmitter

Application : Absolute, relative, or differential pressure, level and vacuum measurement for chemical, oil and gas, pharmaceutical, alimentary, marine etc.

Typology : Level continuous, pressure

Measure principle : Pieoresistive, ceramic

Measuring range : 0~2mg/l

Supply : 12.~30 VDC

Output : 4~20 mA + HART

Photorelays : 3 photorelays (alarm, pre-alarm, fault)

Photorelays : 3 photorelays (alarm, pre-alarm, fault)

Process connection : Flanged, standard screws, triclatri-clamping nuts, welding ring

Process temperature : Stadards :-40~85°C, finned body : -40~130°C, capillary : -40280°C

Ingress protection degree : Ø 27 and Ø 50 Housing: IP65, Ø 35 and Ø 55 Housing: IP67
Titanium Ø 27 Housing: IP65
Titanium Ø 35 Housing: IP67
Titanium Ø 50 Housing: IP65
Titanium Ø 55 Housing: IP67
Aluminum Ø 30 Housing: IP65

ATEX Approval : Yes

 

T72 Submersible Level Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : T72 Pressure Series

Type : SMART submersible level transmitter

Application : Level measurement for chemical, oil and gas, pharmaceutical, alimentary, marine etc.

Typology : Level continuous

Measure principle : Pieoresistive, ceramic

Measuring range : 0~0.35 bar, 0~50 bar

Supply : 12.5~30 VDC

Output : 4~20 mA + HART

Process connection : 1" G-M, 1/2" G-M, 1/2" NPT-M

Process temperature : -10~80°C

Ingress protection degree : IP68

BMS Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : T72 Pressure Series

Type : Bubbling system for level measurement

Application : For level detection based on the measurement of hydrostatic presssure

Typology : System

Supply : 12.5~30 VDC

Output : 4~20 mA + HART

Process temperature : -40~45°C

Ingress protection degree : IP65

 

 

 

HMI Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : HMI Series

Type : HMI (Touch panel)

Application : HMI-used for monitoring and alarm management using HART communication protocol

Typology : System

Supply : 16~32 VDC

Processor : AMD Geode LX, 500MHz (LX800)

RAM Memory : 256 MB SDRAM

Memory : 4 GB SSD Disk, compact flash

OS : Window XP

GPIO : 12 inputs (16 input in the only ON/OFF version)

Ethernet : (R45) 10/100 Base-T

HART : 2 Buses, Max 30 sensors

Modbus : RS485, TCP/IP, UDP/IP

Input & output : NPN open collector fault, Horn & Beacon

Screen : 8" LCD Colours 800 x 600 

Chasis material : ANSI304 steel

Button material : Stainless steel

Env. temperature : 5~60°C

Marine type approval : RINA 

Ingress protection degree : IP65

 

THP Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : THP Series

Type : Pneumatic pressure transmitter

Application : To detect pressure of liquids,gas and vapors for industrial and marine application

Measuring principle : Pneumatic

Typology : Pressure

Supply : 1.5 bar @ 22 psi 

Output signal : 0.2~1 bar, 3~15 psi

Air consumption : 250 NL/h max

Measuring range : Max : 0~8 bar,Min : 0~1.5 bar

Process connection : Flange or screw, welding ring, clamp , other on request

Process temperature : -10~80°C

Housing & basement : Painted aluminum alloy

Diaphragm : Viton-PTFE

18I Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : 18I Series

Type : Pneumatic pressure transmitter

Application : To measure level of liquid in wells, chests, lakes, water treatment plants, tanks etc.

Measuring principle : Ceramic

Typology : Level continuos 

Supply : 11~30VDC

Output signal : 4~20mA

Measuring range : 0~1 bar,0~1000 bar

Process connection : PLug with holes

Process temperature : -10~80°C

Ingress protection degree : IP68

ATEX Approval: No

27A Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : 27A Series

Type : Electronic level, pressure and vacuum transmitter

Application : To measure level of liquid in wells, chests, lakes, water treatment plants, tanks etc.

Measuring principle :Piezoresistive, ceramic

Typology : Pressure

Supply : 2 wires (11~30 VDC), 3 wires (16~26 VDC)

Output signal : 2 wires (4~20 mA), 3 wires (0~5 or 0~10 VDC)

Measuring range : 0~1 bar,0~1000 bar

Process connection : Threads from 1/4″ G or NPT Flanges from DN15 or 1” ½ Sanitary connection Welding nut connection.

Process temperature : -40~85°C, finned body : -40~130°C, capillary : -40~280°C

Ingress protection degree : Ø 27 and Ø 50 Housing: IP65, Ø 35 and Ø 55 Housing: IP67 

ATEX Approval: Yes

M3 Series

Quick View

View Full Details

Brand : Valcom

Media : Liquid

Model : M3 Series

Type : Three valves and three ways manifold M3 series

Application : To measure level of liquid in wells, chests, lakes, water treatment plants, tanks etc.

 

Typology : Accessories

Process connection : 1/2" NPT Flanged

Process temperature : -40~85°C, finned body : -40~130°C, capillary : -40~280°C

Ingress protection degree : Ø 27 and Ø 50 Housing: IP65, Ø 35 and Ø 55 Housing: IP67