A unit of fingerprint identification easily connected with HMI via USB.(link is external)
USB Transfer Cable (2m)
CA3-USBCB-01
Cable for transferring screen data between a PC (USB Type A) and the GP unit (USB Type A).(link is external)
USB Transfer Cable (1.8m)
ZC9USCBMB1
Cable for transferring screen data between a PC (USB Type A) and the GP unit (USB mini- B).
USB Cable (5m)
FP-US00
Connects a USB printer. (TYPE-B)
USB Panel-mount Extension Cable (1m)
ZC9USEXMB1
Extension cable that attaches to the USB (mini-B) interface on the front side of the operation panel.
USB Front Cable (1m)
CA5-USBEXT-01
Extension cable for attaching to USB port on front panel.(link is external)
USB-Serial (RS-232C) Conversion Cable (50cm)
CA6-USB232-01
Cable for converting a GP unit’s USB interface into a serial interface (RS-232C). Allows connection to modems *3 or barcode readers *3 that support RS-232C.
USB-Serial (RS-422/485) Conversion Adapter
PFXZCBCBCVUSR41
Cable for connecting a GP unit (USB Type A) with an external device (RS-422/RS-485)
*4Purchase this product when installing GP-Pro EX in a second or subsequent PC. One license is required for each PC.
*5Group License consists of one set of Serial No./Key Code for installation on 10 PCs. (Should be used in the same office. Supports GP-Pro EX Ver. 3.1 or later.)
*6This is available for the models with Ethernet port.
*7Includes the settings editor and Runtime.
*8Purchase this product when installing the settings editor and Run time in subsequent PCs.
*9Purchase this license when installing only Run time in subsequent PCs. One license is required for each PC.
*10Use 12.1-inch Environment Cover for GP-4501TW because of the same bezel size (12.1-inch).
*11Does not include GP4100 Series and GP4000M Series.
*12Video images through VM Unit cannot be recorded.
White LED (User nonreplaceable parts. When replacement is required, contact your local distributor.)
Brightness Control
16 Levels (Adjusted with the touch panel or the software)
Backlight Service Life
50,000 hrs. or more (continuous operation at 25°C [77 °F] before backlight brightness decreases to 50%)
Language Fonts
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters) ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.)
Character Sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes
Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
Text
8 x 8 dots
100 char. x 75 rows
8 x 16 dots
100 char. x 37 rows
16 x 16 dots
50 char. x 37 rows
32 x 32 dots
25 char. x 18 rows
Control Memory
Variable Area
SRAM 64 KB (Replaceable Lithium battery for backup memory)
FLASH EPROM 32 MB (including a logic program area)
Data Backup
SRAM 320 KB (Replaceable Lithium battery for backup memory)
Clock Accuracy
±65 sec/month (deviation at room temperature and power is OFF)*3
Touch Panel Type
Resistive Film (analog)
Touch Panel Resolution
1,024 x 1,024
Touch Panel Service Life
1,000,000 times or more
Interface
Serial (COM1)
RS-232C Asynchronous Transmission Data Length: 7 or 8 bits, Parity: none, Odd or Even, Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
Serial (COM2)
RS-422/485 Asynchronous Transmission Data Length: 7 or 8 bits, Parity: none, Odd or Even Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5kbps (MPI) Connector: D-Sub9 (plug)
Ethernet (LAN)
IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX Connector: Modular jack (RJ-45) x 1
USB (TYPE-A)
Conforms to USB2.0 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m [16.4ft.] or less
USB (mini-B)
Conforms to USB2.0 (mini-B) x 1, Communication Distance: 5 m [16.4ft.] or less
SD Card
SD Card Slot x 1
Other font sizes can be set up with the Editor software.
Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
General Specification
International Safety Standards
Rated Input Voltage
DC 24 V
Input Voltage Limits
DC 19.2 to 28.8 V
Allowable Voltage Drop
10 ms or less
Power Consumption
17 W or less
In-Rush Current
30 A or less
Voltage Endurance
AC 1,000 V 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance
DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature
0 to 55 °C [32 to 131 °F]
Storage Temperature
-20 to 60 °C [-4 to 140 °F]
Ambient Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
Storage Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
Dust
0.1 mg/m³ (10-7 oz/ft³) or less (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Atmosphere
Free of corrosive gases
Air Pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
Vibration Resistance
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (approx. 100 min)
Concussion Resistance
IEC/EN61131-2 compliant 147 m/s², X, Y, Z directions for 3 times
Functional grounding: Grounding resistance of 100Ω, 2mm² (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure
IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*4
Cooling Method
Natural air circulation
Weight Approx.
2.5 kg [5.5 lb] or less (display unit only)
External Dimensions
W315x H241x D56 mm [W12.4 x H9.49 x D2.2 in.]
Panel Cut Dimensions
W301.5 x H227.5 mm [W11.87 x H8.96 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*5
The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no ef
Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.
- Makes maintenance simple, even for equipment that is used for extended periods of time.
- Lets you save data even when using equipment that is left unpowered for long periods of time, giving peace of mind.
- It is recommended that batteries are replaced every 5 years. Batteries can be purchased as maintenance items.
No more accidental dropping
Special projections prevent the GP4000 series from being accidentally dropped through the hole when it is being installed in a panel.
Consistent direction of cabling
Thanks to a consistent connection direction for cables and other interfaces, routing of wiring is now simpler than ever.
Compatibility for easy replacement
Since the panel cutting dimensions are the same as conventional models, it is easy to replace only the display unit in an existing facility.
Easy to change the display screen
- The display screen can be changed by using a USB flash memory or SD card, without the need for a software license.
- The screen maintenance can be done without bringing a PC to a production site.
- A person in charge does not have to operate a PC, such as when manufacturing the multiple units of the same equipment.
Commercially available Type A to Mini-B USB cables can be used to transfer screen data.
Conforms to overseas standards for hassle-free export and use with overseas equipment
UL/cUL Hazardous Locations Class I, Division 2 Group A, B, C and D.
Acquired ATEX Zone 2/22 (Gas/Dust)
Acquired KCs (Korean Simple Explosion-proof)
Acquired NEPSI (Chinese Simple Explosion-proof)
Environment-Friendly
Energy Saving - Standard equipped with LED backlight LCD + Lighting adjustment
Energy-saving capabilities have been greatly improved. The GP4000 Series contributes to reducing on-site power consumption in a variety of ways including an on-board LED backlight in all models, and a lighting adjustment function used to decrease and eventually stand-by the display after being idle for a set period of time.
Easily connect multiple USB devices
A controller with serial interface, EZ Series accessory unit, bar code reader, and USB flash drive can be easily connected to the HMI unit.