SCIENCEGATE

  • Home
  • Products
  • Profile
  • About Us
    • Events
    • Career
  • Contacts
 

Contact Us (65) 6561 0488

 

5.7-inch Controller

Input Specifications

Rated Voltage DC24V
Maximum Allowable Voltage DC28.8V
Input Method Sink/ Source Input
Rated Current 6.5mA (DC24V) (IN0, IN2, IN4, IN6)
4.1mA (DC24V) (Other inputs)
Input Resistance Approx. 3.7kΩ (IN0, IN2, IN4, IN6)
Approx. 5.9kΩ (Other inputs)
Input Points 16 points
Common Lines 1
Common Design 16 points/ 1 common line
Operation Range ON Voltage DC19V or more
OFF Voltage DC5V or less
Input Delay Time OFF→ON 0.5 to 20ms *1
ON→OFF 0.5 to 20ms *1
Input Signal Display No LED indicators
Insulation Method Photocoupler isolation
External Connection 38-pin connector (used with Output section)
External Power Supply For Signal: DC24V
5.7 in. input circuit
Page Top

Output Specifications

  OUT0 to OUT3 OUT4 to OUT15
Rated Voltage DC24V
Allowance Voltage Range DC20.4V to DC28.8V
Output Method Sink Output LT3300-S1-D24-K, LT3300-L1-D24-K, LT3301-L1-D24-K
Source Output LT3300-S1-D24-C, LT3300-L1-D24-C, LT3301-L1-D24-C
Maximum Load Voltage 200mA/1point, 1.6A/1 common
Minimum Load Current 1mA 1mA 
(Pulse/ PWM Output Unavailable)
Output Voltage Drop DC0.5V or les
Output Delay Time OFF→ON 5µs or less
(at Output DC24V, 200mA)
0.5m or less
(at Output DC24V, 200mA)
ON→OFF 5µs or less
(at Output DC24V, 200mA)
0.5ms or less
(at Output DC24V, 200mA)
Voltage Leakage (When OFF) 0.1mA or less
Clamp Voltage 39V ±1V
Type of Output Transistor Output
Common Lines 2
Common Design 8 points/ 1 common line × 2
External connection 38-pin connector (also used for Input)
Output Protection Type Output is unprotected
Internal Fuse 2.5A, 125V Chip fuse × 2 (not replaceable)
Surge Control Circuit Zener diode
Output points*1 16 points
Input Signal Display No LED indicators
Isolation Method Photocoupler Isolation
External Power Supply For Signal: DC24V
5.7 in. output circuit
Page Top

High-speed Counter/ Pulse Catch Input Specifications

  High-speed Counter Pulse Catch Input
Input *1 DC24V Open collector DC24V
Open collector
Single phase (4 points) Double phase 
(1 point or 2 points)
Input Points CT0(IN0),
CT1(IN2),
CT2(IN4),
CT3(IN6)
defined by user
CT0(IN0), CT1(IN2) (used as pair)
CT0: A phase, CT1: B phase
CT2 (IN4), CT3 (IN6) 
CT3: Phase A, CT3: Phase B
defined by user
IN0, IN2, IN4, IN6
defined by user
Minimum Pulse Width 
(Pulse Input)
Minimum Pulse Width
Minimum Pulse Width

Count Speed

(Rise, Fall Time)

enumeration speed
-
Phase 1 phase 90 degree-phase differentional 2-phase signal / 1-phase + directional signal
-
High Speed Count Frequency 100Kpps 50Kpps
-
Count Edge Designation Available Not available
-
Count Register 32-bit UP/ DOWN counter
-
Counter Mode Charge Set through software
-
Upper/ Lower Limit Settings Not available
-
Preload/Prestrobe Available
-
Marker Input
(Clear Counter Value)
None IN3, IN7
-
Page Top

Pulse/ PWM Output Specifications

  Pulse output PWM output
Output Points*1 4 points
Output Method PLS0 to PLS3
(OUT0 to OUT3)
defined by user
PWM0 to PWM3
(OUT0 to OUT3)
defined by user
Load Voltage DC24V
Minimum Load Current 1mA
Maximum Output Frequency Up to 65kHz possible per point (set through software)
Varies depending on the number of CH of High-speed counter, pulse output.
Pulse Acceleration Deceleration Speed Available Not available
ON Duty 50% ± 10% (at 65kHz)*2 19 to 81% (at 65kHz)*3
  1. *1   Digital filter can be set intervals of 0.5ms.
  2. *2   The ON Duty error (10%) will be reduced if the Output frequency is low.
  3. *3   ON duty (effective range) increases as the output frequency setting is lower.
Page Top
 
 

 

 

Specification of LT3201-A1-D24-K

LT-3201A SinkOutput type
Model: LT3201-A1-D24-K

Thumbnail
  • Built-in DIO 18 points
  • Expansion Units x 2
  • CAN Open
  • Serial
  • USB
  • Ethernet
Monochrome LCD (Amber/Red)   (8 Shades) /   QVGA
  • ManualDesign Data (DXF)

Functional Specification

Display Type STN Color LCD
Display Size 5.7"
Resolution 320 x 240 pixels (QVGA)
Dot pitch W0.36 x H0.36 mm [W0.01 x H0.01 in.]
Effective Display Area W117.2 x H88.4 mm [W4.61 x H3.48 in.]
Display Colors 4,096 Colors
Backlight White LED (User nonreplaceable parts. Factory replacement required.)
Brightness Control 8 Levels (Adjusted with the touch panel)
Contrast Control 8 Levels (Adjusted with the touch panel)
Backlight Service Life 50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50%)
Language Fonts Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.
Character Sizes Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
Text 8 x 8 dots 40 char. x 30 rows
8 x 16 dots 40 char. x 15 rows
16 x 16 dots 20 char. x 15 rows
32 x 32 dots 10 char. x 7 rows
Control Memory Variable Area SRAM 64 KB (uses lithium battery)
Program Area FLASH EPROM 132 KB
Number of Step Equivalent to 15,000 steps*2
Application Memory FLASH EPROM 6 MB*3
Data Backup SRAM 128 KB (Lithium battery for backup memory)
Clock Accuracy ±65 sec/month (deviation at room temperature and power is OFF)*4
Touch Panel Type Resistive Film (analog)
Touch Panel Resolution 1,024 x 1,024
Touch Panel Service Life 1,000,000 times or more
Interface Serial (COM1) RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
Ethernet (LAN) IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
USB (TYPE-A) Conforms to USB1.1 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
AUX/Expansion Unit Communication Expansion Unit x 1*5
Control DIO (Source Type) 16-Point Input Sink Source, , 16-Point Output Source, Connector: 38pin
  1. *1     Other font sizes can be set up with the Editor software.
  2. *2     Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.
  3. *3     Capacity available for user application.
  4. *4     Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
  5. *5     EX Module and Communication Expansion Unit cannot be used at the same time.
Page Top

General Specification

International Safety Standards
  • EU RoHS Directives
    Download
  •  
  • UL,cUL(508) Listed
    Download
  •  
  • ANSI/CSA(UL508+1604) Listed
    Download
  •  
  • CE
    Download
  •  
  • CSA
     
  •  
  • KC
     
  •  
  • Gost-R
     
Rated Input Voltage DC 24 V
Input Voltage Limits DC 19.2 to 28.8 V
Allowable Voltage Drop 3 ms or less
Power Consumption 27 W or less
In-Rush Current 30 A or less
Voltage Endurance AC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature 0 to 50 ℃
Storage Temperature -20 to +60 ℃
Ambient Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Storage Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Dust 0.1 mg/m³ or less (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Air Pressure (altitude range) 800 to 1,114 hPa (2,000 m above sea level or less)
Vibration Resistance IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)
Concussion Resistance IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
Noise Immunity Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator)
Electrostatic Discharge Immunity Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
Grounding Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure Equivalent to IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*6
Installation Configuration Embedded panel
Cooling Method Natural air circulation
Weight Approx. 1 kg [2.2 lb] or less (display unit only)
External Dimensions W167.5 x H135 x D78 mm [W6.59 x H5.31 x D2.87 in.]
Panel Cut Dimensions W156 x H123.5 mm [W6.14 x H4.86 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*7
  1. *6     The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
  2. *7     Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
Page Top

External Dimensions / Interfaces

5.7

Panel Cut-out

5.7
Page Top
 
 

 

 

Specification of LT3301-L1-D24-K

LT-3301L SinkOutput type
Model: LT3301-L1-D24-K

Thumbnail
  • Built-in DIO 32 points
  • Expansion Units x 3
  • CAN Open
  • Serial x1
  • USB
  • Ethernet
Monochrome LCD   (16 Shades) /   QVGA 
  • ManualDesign Data (DXF)

Functional Specification

Display Type STN Color LCD
Display Size 5.7"
Resolution 320 x 240 pixels (QVGA)
Dot pitch W0.36 x H0.36 mm [W0.01 x H0.01 in.]
Effective Display Area W117.2 x H88.4 mm [W4.61 x H3.48 in.]
Display Colors 4,096 Colors
Backlight White LED (User nonreplaceable parts. Factory replacement required.)
Brightness Control 8 Levels (Adjusted with the touch panel)
Contrast Control 8 Levels (Adjusted with the touch panel)
Backlight Service Life 50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50%)
Language Fonts Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.
Character Sizes Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
Text 8 x 8 dots 40 char. x 30 rows
8 x 16 dots 40 char. x 15 rows
16 x 16 dots 20 char. x 15 rows
32 x 32 dots 10 char. x 7 rows
Control Memory Variable Area SRAM 64 KB (uses lithium battery)
Program Area FLASH EPROM 132 KB
Number of Step Equivalent to 15,000 steps*2
Application Memory FLASH EPROM 6 MB*3
Data Backup SRAM 128 KB (Lithium battery for backup memory)
Clock Accuracy ±65 sec/month (deviation at room temperature and power is OFF)*4
Touch Panel Type Resistive Film (analog)
Touch Panel Resolution 1,024 x 1,024
Touch Panel Service Life 1,000,000 times or more
Interface Serial (COM1) RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
Ethernet (LAN) IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
USB (TYPE-A) Conforms to USB1.1 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
AUX/Expansion Unit Communication Expansion Unit x 1*5
Control DIO (Source Type) 16-Point Input Sink Source, , 16-Point Output Source, Connector: 38pin
  1. *1     Other font sizes can be set up with the Editor software.
  2. *2     Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.
  3. *3     Capacity available for user application.
  4. *4     Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
  5. *5     EX Module and Communication Expansion Unit cannot be used at the same time.
Page Top

General Specification

International Safety Standards
  • EU RoHS Directives
    Download
  •  
  • UL,cUL(508) Listed
    Download
  •  
  • ANSI/CSA(UL508+1604) Listed
    Download
  •  
  • CE
    Download
  •  
  • CSA
     
  •  
  • KC
     
  •  
  • Gost-R
     
Rated Input Voltage DC 24 V
Input Voltage Limits DC 19.2 to 28.8 V
Allowable Voltage Drop 3 ms or less
Power Consumption 27 W or less
In-Rush Current 30 A or less
Voltage Endurance AC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature 0 to 50 ℃
Storage Temperature -20 to +60 ℃
Ambient Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Storage Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Dust 0.1 mg/m³ or less (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Air Pressure (altitude range) 800 to 1,114 hPa (2,000 m above sea level or less)
Vibration Resistance IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)
Concussion Resistance IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
Noise Immunity Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator)
Electrostatic Discharge Immunity Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
Grounding Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure Equivalent to IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*6
Installation Configuration Embedded panel
Cooling Method Natural air circulation
Weight Approx. 1 kg [2.2 lb] or less (display unit only)
External Dimensions W167.5 x H135 x D78 mm [W6.59 x H5.31 x D2.87 in.]
Panel Cut Dimensions W156 x H123.5 mm [W6.14 x H4.86 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*7
  1. *6     The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
  2. *7     Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
Page Top

External Dimensions / Interfaces

5.7

Panel Cut-out

5.7
Page Top
 
 

 

 

Specification of LT3300-L1-D24-K

LT-3300L SinkOutput type
Model: LT3300-L1-D24-K

Thumbnail
  • Built-in DIO 32 points
  • Expansion Units x 3
  • CAN Open
  • Serial x1
  • USB
  • Ethernet
Monochrome LCD   (16 Shades) /   QVGA 
  • ManualDesign Data (DXF)

Functional Specification

Display Type STN Color LCD
Display Size 5.7"
Resolution 320 x 240 pixels (QVGA)
Dot pitch W0.36 x H0.36 mm [W0.01 x H0.01 in.]
Effective Display Area W117.2 x H88.4 mm [W4.61 x H3.48 in.]
Display Colors 4,096 Colors
Backlight White LED (User nonreplaceable parts. Factory replacement required.)
Brightness Control 8 Levels (Adjusted with the touch panel)
Contrast Control 8 Levels (Adjusted with the touch panel)
Backlight Service Life 50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50%)
Language Fonts Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.
Character Sizes Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
Text 8 x 8 dots 40 char. x 30 rows
8 x 16 dots 40 char. x 15 rows
16 x 16 dots 20 char. x 15 rows
32 x 32 dots 10 char. x 7 rows
Control Memory Variable Area SRAM 64 KB (uses lithium battery)
Program Area FLASH EPROM 132 KB
Number of Step Equivalent to 15,000 steps*2
Application Memory FLASH EPROM 6 MB*3
Data Backup SRAM 128 KB (Lithium battery for backup memory)
Clock Accuracy ±65 sec/month (deviation at room temperature and power is OFF)*4
Touch Panel Type Resistive Film (analog)
Touch Panel Resolution 1,024 x 1,024
Touch Panel Service Life 1,000,000 times or more
Interface Serial (COM1) RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
Ethernet (LAN) IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
USB (TYPE-A) Conforms to USB1.1 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
AUX/Expansion Unit Communication Expansion Unit x 1*5
Control DIO (Source Type) 16-Point Input Sink Source, , 16-Point Output Source, Connector: 38pin
  1. *1     Other font sizes can be set up with the Editor software.
  2. *2     Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.
  3. *3     Capacity available for user application.
  4. *4     Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
  5. *5     EX Module and Communication Expansion Unit cannot be used at the same time.
Page Top

General Specification

International Safety Standards
  • EU RoHS Directives
    Download
  •  
  • UL,cUL(508) Listed
    Download
  •  
  • ANSI/CSA(UL508+1604) Listed
    Download
  •  
  • CE
    Download
  •  
  • CSA
     
  •  
  • KC
     
  •  
  • Gost-R
     
Rated Input Voltage DC 24 V
Input Voltage Limits DC 19.2 to 28.8 V
Allowable Voltage Drop 3 ms or less
Power Consumption 27 W or less
In-Rush Current 30 A or less
Voltage Endurance AC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature 0 to 50 ℃
Storage Temperature -20 to +60 ℃
Ambient Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Storage Humidity 10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Dust 0.1 mg/m³ or less (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Air Pressure (altitude range) 800 to 1,114 hPa (2,000 m above sea level or less)
Vibration Resistance IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)
Concussion Resistance IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
Noise Immunity Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator)
Electrostatic Discharge Immunity Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
Grounding Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure Equivalent to IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*6
Installation Configuration Embedded panel
Cooling Method Natural air circulation
Weight Approx. 1 kg [2.2 lb] or less (display unit only)
External Dimensions W167.5 x H135 x D78 mm [W6.59 x H5.31 x D2.87 in.]
Panel Cut Dimensions W156 x H123.5 mm [W6.14 x H4.86 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*7
  1. *6     The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
  2. *7     Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
Page Top

External Dimensions / Interfaces

5.7

Panel Cut-out

5.7
Page Top
 
 

 

 
Product CAD Data
 >Hardware  >LT3000 Series

Please be acknowledged of the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
1. Digital shall retain all intellectual property rights in the files that Digital provides for this service.
2. Who, uses or plans to use Digital's products, may download and use any file.
3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that Digital provides for this service shall be prohibited.
However, for manual PDFs, samples, BMP images and CAD files, you may reprint, dupulicate, quote a part of the content or the whole on your company's specification sheets, or instruction manuals for built-in products. Also you may change the layout of the content.
4. This download service is provided through the Internet. Please acknowledge that Digital provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
5. Not all of the Product CAD Data Download of Digital products are provided in this service. Please acknowledge prior to using this service that the Product CAD Data of certain products might not be provided.
6. Please use this service at your own risk.

Notices:
1. Files are subject to deletion, or modification of the contents or specifications without notice.
2. Please confirm that the downloading file size completely accords with the downloaded file size.
3. If the file sizes do not match, delete the file without decompressing (executing) and then download the same file once again.

LT3000 Series

Model File size Update
LT3201-A1-x 719KB 2007.2.2
LT3300-x1-D24-x 388KB 2009.4.23
LT3301-L1-D24-x 407KB 2008.7.9

2D CAD file (DXF)
- As a DXF file is an unstable file, data compatibility is not perfect.Reading data might be imperfect depending on CAD software you use.
- The downloaded file is a self-decompressing file. Double-click on it, and the DXF file will be unfolded.
-

Digital has confirmed that it's possible to read the DXF file above via the CAD software below.

Company name   Auto Desk
CAD software name   AutoCAD LT 2000i

 
 

 

  1. Proface|LT3000 Series|Manual
  2. Proface|LT3000 Series|Specifications|LT3300-S1-D24-K
  3. Proface|LT3000 Series|Features
  4. Proface|LT3000 Series|Lineup

Page 99 of 126

  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • Takikawa
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2025. ALL RIGHTS RESERVED.