KVX-211
|
Brand : Kansai
Media : Powder, Granules, Liquid
Model : KVX-211 (Remote type, separated amplifier)
Type : Vibration type levlel switch
Application : High sensitivity type detecting low-density powders.Can detect substances with relative permittivity and moisture percentage.
Power source :105/210VAC ±10% 50/60Hz. DC24V is available as option.
Sensitivity : Over 0.1 specific gravity (over 0.03 as option)
|
Output contact : SPDT, 250VA, 10A, 30VDC 10A (Resistive load)
AMP temp. : -20°C~60°C (no condensation/ no freezing)
Detector temp. : -20°C~80°C (integrated type) (no condensation / no freezing)
Detector material : 304SS (316L SS option)
Allowable pressure : 980kPa
Mounting : Horizontal/vertical mounting
Process connection : R1
Enclosure rating : Equivalent to IP-67
|
|
XV2-111
|
Brand : Kansai
Media : Powder, Granules, Liquid
Model : KV2-111 (Standard type, R3/4 screwed joint)
Type : Vibration type levlel switch
Application : High sensitivity type detecting low-density powders.Can detect substances with relative permittivity and moisture percentage.
Power source :105/210VAC ±10% 50/60Hz. DC24V is available as option.
Sensitivity : Over 0.1 specific gravity (over 0.03 as option)
|
Output contact : SPDT, 250VA, 10A, 30VDC 10A (Resistive load)
AMP temp. : -20°C~60°C (no condensation/ no freezing)
Detector temp. : -20°C~80°C (integrated type) (no condensation / no freezing)
Detector material : 304SS (316L SS option)
Allowable pressure : 980kPa
Mounting : Horizontal/vertical mounting
Process connection : R3/4 or G3/4B
Enclosure rating : Equivalent to IP-67
|
|
XV2-211
|
Brand : Kansai
Media : Powder, Granules, Liquid
Model : XV2-211 (Standard type, R3/4 screwed joint), separated amplifier
Type : Vibration type levlel switch
Application : High sensitivity type detecting low-density powders.Can detect substances with relative permittivity and moisture percentage.
Power source :105/210VAC ±10% 50/60Hz. DC24V is available as option.
Sensitivity : Over 0.1 specific gravity (over 0.03 as option)
|
Output contact : SPDT, 250VA, 10A, 30VDC 10A (Resistive load)
AMP temp. : -20°C~60°C (no condensation/ no freezing)
Detector temp. : -20°C~80°C (integrated type) (no condensation / no freezing)
Detector material : 304SS (316L SS option)
Allowable pressure : 980kPa
Mounting : Horizontal/vertical mounting
Process connection : R3/4 or G3/4B
Enclosure rating : Equivalent to IP-67
|
|
KLI
|
Brand : Kansai
Media : Powder, Granules, Liquid, Surface Interface
Model : KLI (Amplifier remote type)
Type : Capacitance type
Application : Suitable for condition such as high temperature and pressure, strong acid, strong alkali, conductive, insulating.
Power source :105/210VAC ±15% 50/60Hz. DC24V is available as option.
Power consumption : 4VA
|
Output signal : DC 4-20mA (Resistive load), max.500Ω (-)grounded
Sensitivity : 10pF . 30pF . 300pF . 3000pF (F.S)
Accuracy : 1%
Housing : Outdoor wall mount or panel built-in
Length of exclusive cable : max.50m (25m max. for the sensitivity class1)
Operating temp. : -20°C~70°C
Allowable pressure : 980kPa
Mounting : Vertical mounting
Enclosure rating : Equivalent to IP-55
|
|
KLT
|
Brand : Kansai
Media : Powder, Granules, Liquid, Surface Interface
Model : KLT (Amplifier built-in type)
Type : Capacitance type
Application : Suitable for condition such as high temperature and pressure, strong acid, strong alkali, conductive, insulating.
Power source :105/210VAC ±15% 50/60Hz. DC24V is available as option.
|
Power consumption : 4VA
Output signal : DC 4-20mA (Resistive load), max.500Ω (-)grounded
Sensitivity : 10pF . 30pF . 300pF . 3000pF (F.S)
Accuracy : 1%
Operating temp. : -20°C~70°C
Allowable pressure : 980kPa
Mounting : Vertical mounting
Enclosure rating : Equivalent to IP-55
|
|
KLG
|
Brand : Kansai
Media : Powder, Granules, Liquid, Surface Interface
Model : KLG (Intrinsically safe, explosion-proof type)
Type : Capacitance type
Application : Suitable for condition such as high temperature and pressure, strong acid, strong alkali, conductive, insulating.
Power source :100/110VAC or 200/220VAC (Distributor option)
Power consumption : 4VA
|
Output signal : DC 4-20mA (Resistive load), max.100Ω
Sensitivity : 10pF . 30pF. 3000pF
Accuracy : 1%
Housing : Outdoor wall mounting
Length of exclusive cable : max.25m
Operating temp. : -20°C~70°C
Allowable pressure : 980kPa
Mounting : Vertical mounting
Enclosure rating : Equivalent to IP-66
|
|
KSL-T8
|
Brand : Kansai
Media : Powder, Granules, Liquid, Lamp, Underwater solid
Model : KSL-T8 (CPU built-in)
Type : Sounding bob type KSL series
Application : Simple mechanical detection method. Not easily affected by measured substances and ambient condition, provides stable indications.
Power source :100 or 200VAC, single phase 50/60Hz
Power consumption : Max 150VA
Measuring span : Standard 20m (40m option)
Measuring method : Pulse counting
Measuring unit : 1 pulse/10cm or 1 pulse/1cm
Measuring accuracy : ±10cm / ±1cm
Motor : Single-phase,reversible, output 40W, 30 minutes rating, with brake
|
Output : Current signal DC4~20mA (indicate remains),DC20~4mA (indicate vacated portion),(User can set up either one),Pulse contact signal 1 pulse / 1cm (No-volt signal),1pulse / 10cm(User can set up either one)
Output contact : Reset contact/ for Remote Indication Counter, ON at the time of reset, Failure Alarm Contact/Flickers when the measuring tape is cut off. The contact is closed when the weight is buried.
Ambinet temp. :-10°C~50°C (no freezing/condensation)
Inside tank : -10°C~80°C (no freezing/condensation)
Mounting : Vertical mounting , Flange (JIS 5K 125A)
Enclosure rating : Equivalent to IP-67
|
|
KSL-MT
|
Brand : Kansai
Media : Powder, Granules, Liquid, Lamp, Underwater solid
Model : KSL-ML (CPU built-in)
Type : Sounding bob type KSL series
Application : Simple mechanical detection method. Not easily affected by measured substances and ambient condition, provides stable indications. Suitable for level control of Hopper Bin or the like in smaller capacity
Power source :100 or 200VAC, single phase 50/60Hz
Power consumption : Max 150VA
Measuring span : Standard 20m (40m option)
Measuring method : Pulse counting
Measuring unit : 1 pulse/10cm or 1 pulse/1cm
Measuring accuracy : ±10cm / ±1cm
|
Motor : Single-phase,reversible, output 25W, 30 minutes rating, with brake
Output : Current signal DC4~20mA (indicate remains),DC20~4mA (indicate vacated portion)(User can set up either one),Pulse contact signal 1 pulse / 1cm (No-volt signal),1pulse / 10cm(User can set up either one)
Output contact : Reset contact/ for Remote Indication Counter, ON at the time of reset, Failure Alarm Contact/Flickers when the measuring tape is cut off. The contact is closed when the weight is buried.
Ambinet temp. :-10°C~50°C (no freezing/condensation)
Mounting : Vertical mounting , Flange (JIS 5K 100A)
Enclosure rating : Equivalent to IP-67
|
|
KSL-T2
|
Brand : Kansai
Media : Powder, Granules, Liquid, Lamp, Underwater solid
Model : KSL-T8 (CPU built-in)
Type : Sounding bob type KSL series
Application : Simple mechanical detection method. Not easily affected by measured substances and ambient condition, provides stable indications.
Power source :100 or 200VAC, single phase 50/60Hz
Power consumption : Max 150VA
Measuring span : Standard 20m (40m option)
Measuring method : Pulse counting
Measuring unit : 1 pulse/10cm
Measuring accuracy : ±10cm
|
Motor : Single-phase,reversible, output 40W, 30 minutes rating, with brake
Output : Possible to control 4-20mA output by combining an optional control unit and P / I converter.
Output contact : Possible to control both upper and lower output by combining an optional control unit and P / I converter.
Ambinet temp. :-10°C~50°C (no freezing/condensation)
Inside tank : -10°C~80°C (no freezing/condensation)
Mounting : Vertical mounting , Flange (JIS 5K 100A)
Enclosure rating : Equivalent to IP-33
|
|
KSL-W2B
|
Brand : Kansai
Media : Powder, Granules, Liquid, Lamp, Underwater solid
Model : KSL-W2B (CPU built-in)
Type : Sounding bob type KSL series
Application : Simple mechanical detection method. Not easily affected by measured substances and ambient condition, provides stable indications. Suitable for level control of Hopper Bin or the like in smaller capacity
Power source :100 or 200VAC, single phase 50/60Hz
Power consumption : Max 70VA
Measuring span : Standard 20m (40m option)
Measuring method : Pulse counting
Measuring unit : 1 pulse/10cm
|
Measuring accuracy : ±10cm
Motor : Single-phase,reversible, output 15W, 30 minutes rating, with brake
Output : Possible to control 4-20mA output by combining an optional control unit and P / I converter.
Output contact : Possible to control both upper and lower output by combining an optional control unit and P / I converter.
Ambinet temp. :-10°C~50°C (no freezing/condensation)
Inside tank :-10°C~80°C (no freezing/condensation)
Mounting : Vertical mounting , Flange (JIS 5K 100A)
Enclosure rating : Equivalent to IP-33
|
|