Contact Us (65) 6561 0488

 
 Manual
 Software
 
 

THE INNOVATIVE SOFTWARE

The intuitive and easy to use software allows you to read and program data of DAT11, DAT 1400, MCT 1302 and UWT 6008.

What makes DAT11, DAT 1400, MCT 1302 and UWT 6008 different from any other products is the software, supplied by Pavone Sistemi is for free with the product. 

Thanks to the software, all the operations connected with the product can be directly managed from the PC.

This software can be used for reading and programming data via USB connection.

Developed with a bottom-up approach, the result is an intuitive and user friendly software as well as easy to use.

 

Main Functions:

 Setup

 Calibration

 Filters management

 Testing the inputs, the outputs and the analog

 Acquiring weight values and exporting in .Csv

 Data logger function

 Data back up

 Restore previously saved data.

 
 

FILTER

Can set the weight stabilization filter, can use preset filters or set a manual filtering by selecting "Manual" and change the numbers manually.

 

The DAT11, DAT 1400, MCT 1302 and UWT 6008 allow you to optimize the weighs by using the FILTER function that combined with a reading speed up to 1000Hz guaranteed by our latest generation of internal digital analogue converter, will allow you to obtain more accurate and repeatable results as well as a fast and stable reading. There are pre-configured filters that respond to the main applications (weighing of: mixers, turbo emulsifiers, vibratung tanks, stations on start & stop belts, etc.), as well as the possibility of a fully customizable filter. 
 
As for the DATALOGGER function, also in this case the software  supplied becomes a “gem” to manage the configuration parameters, to test and view the answers of the “filtered” instrument. 
 
All supported by a graph that in real time will show you the differences between the values filtered and not, helping you in case you use the custom filter in the configuration of the individual parameters.
 
 

 

For CALIBRATION, there are 3 buttons:

ZERO: Unloaded system press to make the calibration of Zero

ACQUIRE: Enter in the box "Weight' the weight value loaded on the system and press the key to perform the FS calibration.f

RESET CALIBRATION: Cancel the last calibrated performed

 

Table calibration is another feature that makes the DAT 11, DAT 1400, MCT 1302 and UWT 6008 a unique tool. The possibility of attributing to a force, a certain defined weight value, allows this transmiher to be used in many applications.
 
An example is the tensiometric systems where the values read by the load cells are not translatable by weight except by calculations that should be done at each reading, slowing down the process of weight acquisition.
 
 

 

TABLE CALIBRATION

Table calibration is another feature that makes the DAT 11, DAT 1400, MCT 1302 and UWT 6008 a unique tool. The possibility of attributing to a force, a certain defined weight value, allows this transmiher to be used in many applications.

 
An example is the tensiometric systems where the values read by the load cells are not translatable by weight except by calculations that should be done at each reading, slowing down the process of weight acquisition.
 
 
 

DATA LOGGER

Can set a data logger from PC, it can be used to capture data of an application and then check them in laboratory

3 types of logger acquisition: 

MANUAL: The operation of START and STOP is handled manually by pressing the buttons

TIME: Set the no. of seconds you want to get data

N°LOG: Set the no. of log to be acquired

The functionality of the data logger already present in the DAt 11, DAT 1400, MCT 1302 and UWT 6008, in which can choose the defined timing or customize the interval for starting and stopping the reading and recording the weight value (on optional alibi memory), is enhanced by the  software provided with the instrument, by connecting the DAT 1400, MCT 1302 and UWT 6008 via USB to the pc on which optimation is installed, in a simple and intuitive way you will find a complete monitoring and verification station.

 

You can configure the time intervals using a user friendly interface, define where to save the file with the recording of the weighs, date and time of each survey, perhaps on a network file that is visible and can be consulted by more people if necessary.

 
 

 

 
Among the weight transmitters, DAT 11 is the fastest to receive, convert and transmit data thanks to a more performing A/D converter. Thanks to its small size and compact design, the DAT 11 weight transmitter can be inserted in any work environment without taking up too much space. DAT 11 is a customizable product that has a mechanical keyboard with a programmable key block from which it is possible to manually set the weight filter with predetermined values or with individually adjustable parameters. The DAT 11 weight transmitter features removable screw terminal blocks, selectable logic input function, voltage or current analog input, unipolar or bipolar analog output, RS485 junction box connection and peak hold function for dynamic measurements. DAT 11 is a product in step with the times. It complies with EN45501, and the Fieldbus data are updated to 125Hz. Compared to traditional weight transmitters, DAT 11 contains a USB port which allows the firmware update, the connection to the Optimation software and the connection to TESTER 1008, which facilitates calibration and troubleshooting. DAT 11 is able to perform various calibrations: "Dead Weight", "Theoretical" and "Data Sheet". In addition, it presents the linearization of the weight calibration on 5 points. Developed specifically by Pavone Weighing Systems and installed free of charge in the weighing instrument, the Optimation software allows you to simplify and perform various operations such as configuring the instrument and correctly and safely saving data through the DATALOGGER function.
 
  • DAT 11

DAT 11

DAT 11 Analog

DAT 11 CANOpen

DAT 11 Devicenet

DAT 11 Ethercat

DAT 11 Ethernet

DAT 11 Ethernet IP

DAT 11 Profibus DP

DAT 11 Profinet

 
 

 

 

DAT 11 Profinet

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • Among the weight transmitters, DAT 11 Profinet is the fastest to receive, convert and transmit data thanks to a more performing A/D converter. Thanks to its small size and compact design, the DAT 11 Profinet weight transmitter can be inserted in any work environment without taking up too much space. DAT 11 Profinet is a customizable product that has a mechanical keyboard with a programmable key block from which it is possible to manually set the weight filter with predetermined values or with individually adjustable parameters. The DAT 11 Profinet weight transmitter features removable screw terminal blocks, selectable logic input function, voltage or current analog input, unipolar or bipolar analog output, RS485 junction box connection and peak hold function for dynamic measurements. DAT 11 Profinet is a product in step with the times. It complies with EN45501, and the Fieldbus data are updated to 125Hz. Compared to traditional weight transmitters, DAT 11 Profinet contains a USB port which allows the firmware update, the connection to the Optimation software and the connection to TESTER 1008, which facilitates calibration and troubleshooting. DAT 11 Profinet is able to perform various calibrations: "Dead Weight", "Theoretical" and "Data Sheet". In addition, it presents the linearization of the weight calibration on 5 points. Developed specifically by Pavone Weighing Systems and installed free of charge in the weighing instrument, the Optimation software allows you to simplify and perform various operations such as configuring the instrument and correctly and safely saving data through the DATALOGGER function.

TECHNICAL DAT 11 PROFINET

Full scale non-Linearity: <0.01%
Display: 6 digit, 7-segment LED red, height 8mm
Frequency signal acquisition: 13 ÷ 1.000 Hz
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation)
Filter: 0.1 ÷ 250 Hz
Excitation voltage: 4 Vdc (max 4 -350 Ohm- load cells)
Analog output Non-Linearity: <0.03%
Temperature drift analog output: 0,002% FS / °C
Power supply: 24 Vdc ±10% - power consumption 5 W
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard via USB
Data storage: 32 Kbytes expandable up to 1024 Kbytes (optional)
 
 

 

 

DAT 11 Profibus DP

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • Among the weight transmitters, DAT 11 Profibus DP is the fastest to receive, convert and transmit data thanks to a more performing A/D converter. Thanks to its small size and compact design, the DAT 11 Profibus DP weight transmitter can be inserted in any work environment without taking up too much space. DAT 11 Profibus DP is a customizable product that has a mechanical keyboard with a programmable key block from which it is possible to manually set the weight filter with predetermined values or with individually adjustable parameters. The DAT 11 Profibus DP weight transmitter features removable screw terminal blocks, selectable logic input function, voltage or current analog input, unipolar or bipolar analog output, RS485 junction box connection and peak hold function for dynamic measurements. DAT 11 Profibus DP is a product in step with the times. It complies with EN45501, and the Fieldbus data are updated to 125Hz. Compared to traditional weight transmitters, DAT 11 Profibus DP contains a USB port which allows the firmware update, the connection to the Optimation software and the connection to TESTER 1008, which facilitates calibration and troubleshooting. DAT 11 Profibus DP is able to perform various calibrations: "Dead Weight", "Theoretical" and "Data Sheet". In addition, it presents the linearization of the weight calibration on 5 points. Developed specifically by Pavone Weighing Systems and installed free of charge in the weighing instrument, the Optimation software allows you to simplify and perform various operations such as configuring the instrument and correctly and safely saving data through the DATALOGGER function.

TECHNICAL DAT 11 PROFIBUS DP

Measuring range: -7.6 ÷ +7.6 mV/V
Input sensitivity: 0.02 µV/count
Full scale non-Linearity: <0.01%
Gain drift: < 0.002% FS/°C
Display: 6 digit, 7-segment LED red, height 8mm
A/D Converter: 24 bit
Internal Resolution: > di 16.000.000 points
Frequency signal acquisition: 13 ÷ 1.000 Hz
Visible resolution (in divisions): 999999
Divisions value (adjustable): x1, x2, x5, x10, x20, x50
Decimal figures range: 0 ÷ 4
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation)
Storage temperature: -20 ÷ +60°C
Filter: 0.1 ÷ 250 Hz
Excitation voltage: 4 Vdc (max 4 -350 Ohm- load cells)
Logic output: 2 optoisolated outputs; max 24 Vdc/100 mA each
Logic input: 2 optoisolated inputs 24 Vdc PNP (external power supply)
Serial port: 1 USB-C device + 1 RS232C + 1 RS485/Fieldbus; ASCII or Modbus RTU protocol
Analog output Non-Linearity: <0.03%
Temperature drift analog output: 0,002% FS / °C
Power supply: 24 Vdc ±10% - power consumption 5 W
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard via USB
Data storage: 32 Kbytes expandable up to 1024 Kbytes (optional)
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety; EN45501 for Metrology
Fieldbus: Profibus DP
 
 

 

 

DAT 11 Ethernet IP

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • Among the weight transmitters, DAT 11 Ethernet IP is the fastest to receive, convert and transmit data thanks to a more performing A/D converter. Thanks to its small size and compact design, the DAT 11 Ethernet IP weight transmitter can be inserted in any work environment without taking up too much space. DAT 11 Ethernet IP is a customizable product that has a mechanical keyboard with a programmable key block from which it is possible to manually set the weight filter with predetermined values or with individually adjustable parameters. The DAT 11 Ethernet IP weight transmitter features removable screw terminal blocks, selectable logic input function, voltage or current analog input, unipolar or bipolar analog output, RS485 junction box connection and peak hold function for dynamic measurements. DAT 11 Ethernet IP is a product in step with the times. It complies with EN45501, and the Fieldbus data are updated to 125Hz. Compared to traditional weight transmitters, DAT 11 Ethernet IP contains a USB port which allows the firmware update, the connection to the Optimation software and the connection to TESTER 1008, which facilitates calibration and troubleshooting. DAT 11 Ethernet IP is able to perform various calibrations: "Dead Weight", "Theoretical" and "Data Sheet". In addition, it presents the linearization of the weight calibration on 5 points. Developed specifically by Pavone Weighing Systems and installed free of charge in the weighing instrument, the Optimation software allows you to simplify and perform various operations such as configuring the instrument and correctly and safely saving data through the DATALOGGER function.

TECHNICAL DAT 11 ETHERNET IP

Measuring range: -7.6 ÷ +7.6 mV/V
Input sensitivity: 0.02 µV/count
Full scale non-Linearity: <0.01%
Gain drift: < 0.002% FS/°C
Display: 6 digit, 7-segment LED red, height 8mm
A/D Converter: 24 bit
Internal Resolution: > di 16.000.000 points
Frequency signal acquisition: 13 ÷ 1.000 Hz
Visible resolution (in divisions): 999999
Divisions value (adjustable): x1, x2, x5, x10, x20, x50
Decimal figures range: 0 ÷ 4
Temperature range: -10 ÷ +50°C (max umidity 85% without condensation)
Storage temperature: -20 ÷ +60°C
Filter: 0.1 ÷ 250 Hz
Excitation voltage: 4 Vdc (max 4 -350 Ohm- load cells)
Logic output: 2 optoisolated outputs; max 24 Vdc/100 mA each
Logic input: 2 optoisolated inputs 24 Vdc PNP (external power supply)
Serial port: 1 USB-C device + 1 RS232C + 1 RS485/Fieldbus; ASCII or Modbus RTU protocol
Analog output Non-Linearity: <0.03%
Temperature drift analog output: 0,002% FS / °C
Power supply: 24 Vdc ±10% - power consumption 5 W
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard via USB
Data storage: 32 Kbytes expandable up to 1024 Kbytes (optional)
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety; EN45501 for Metrology
Fieldbus: Ethernet IP
 
 

 

  1. Pavone | Weight Transmitters | DAT 11 Ethernet
  2. Pavone | Weight Transmitters | DAT 11 Ethercat
  3. Pavone | Weight Transmitters | DAT 11 Devicenet
  4. Pavone | Weight Transmitters | DAT 11 CANOpen

Page 3 of 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2026. ALL RIGHTS RESERVED.