SCIENCEGATE

  • Home
  • Products
  • Profile
  • About Us
    • Events
    • Career
  • Contacts
 

Contact Us (65) 6561 0488

 
  • Series
  • Features
  • Operating Environment
  • Supported Model
  • Downloads
  • Selection Guide
 

BLUE Software Licenses / Operating Environment

 

Software Licenses

Product Name Model# Descriptions Supported models
BLUE Professional PFXBLPCZLSPM** BLUE Professional (DVD) ST6000 Series, STM6000 Series, GP4100 Series Color model, SP5000 Series, PS5000 Series
BLUE Professional Group License PFXBLPCZLGPM** BLUE Professional Group License (3 Licenses / License key code)
BLUE Professional Team License PFXBLPCZLTPM** BLUE Professional Team License (10 Licenses / License key code)
BLUE Professional Fixed Term License PFXBLXCZLSRA** BLUE Professional Fixed Term License (1 License / License key code)
BLUE Basic*1 PFXBLECZLSPM** BLUE Basic (DVD) ST6000 Series, STM6000 Series, GP4100 Series Color model
BLUE Runtime PFXBLRCZLSPM** BLUE Runtime   * for Windows PC PS5000 Series and PC/AT

*1Basic License doesn’t support for WEB API and OPC-UA.
OPC-UA Server is not supported on GP4100 Series Color model

 

Operating Environment

See the manual for the operating environment

 
 

 

 
  • Series
  • Features
  • Operating Environment
  • Supported Model
  • Downloads
  • Selection Guide
 

BLUE Features

 

Refined

High quality graphics

Clearer fonts and screen parts make an obvious difference. The clarity is not affected by zoom level BLUE_03_v2
 

Stylish design

Stylish expression including transparent effects ST6000 Refined_03
 

Simple & Easy

One source, multiple ways to present

Use themes to easily change color set according to a person, place or situation. ST6000 Simple  Easy_01
 

View all needed information at once

BLUE provides means to combine multiple screens to one ST6000 Simple  Easy_02
 

Responsive Behavior (Dock Panel)

Adapt the size of information to meet your needs with one click on the dynamic display. blue_feature_1_en
 

Easily identify patterns with highly flexible graph features

Using various features, including comparisons graphs, can be more expressive than ever before. 12v_new
 

Easy to set navigation

With the navigation feature, you don't need to create screen change switches.
 

Reduced time for layout changes

Use grid cell editing can automatically adjust the object's size and location during layout changes.
 

Easy-to-understand script

Block Script makes visual programming possible. script_new
 

Change the value of a variable without programming

Use a converter to change the value of a variable from the defined unit, range, scale, and expression without programming. Blue_04
 

Connected & Secured

Pro-face connectivity

User-friendly protocols allowing you to connect
your devices with ease via multiple interfaces
and connect OT to IT with OPC-UA server.
ST6000 blue_05
 

Secure remote access solution

"Pro-face Connect" is a ready-to-use solution for Remote Access Over Internet on ST6000 Series without programming or configuring each device.
Start using the cloud based "Pro-face Connect" Smart
Industry solution on your existing network without involving your IT department. No network or firewall configurations are required and still the highest level of security and encryption is in place from end to end, from any PC, tablet and smartphone to your machinery.
ST6000 Pro-face connect
 

Enhanced cybersecurity

Enhanced cybersecurity against basic intentional attacks

•Need admin rights to download project to HMI target
•Auto user log out after predefined idle time
•Doing security checking during booting
•Secure Ethernet download supported by IPSec and
password protected project file
AchillesCertifiedBlue
 
 

 

 
  • Series
  • Features
  • Operating Environment
  • Supported Model
  • Downloads
  • Selection Guide
 

What is BLUE?

BLUE is versatile software for more interactive manufacturing.

Product Features

Rich and expressive interfaces and intuitive operation

Anyone can instantly reach easily understandable information.

  • Responsive design shows easy-to-see and desired information.
  • Familiar smartphone like gestures for navigation and operation.
  • Just one step to show detailed information with the Zoom function.
  • Clearer fonts and parts make an obvious difference.
  • View all needed information at once. BLUE provides means to combine multiple screens to one.

Effective use of equipment information

With OPC-UA Server supported, you can transfer equipment information smoothly to a host database.

A wide variety of connection device drivers available

Numerous control devices around the world can be connected. Users can select a driver that meets their needs.

New design style reduces time for screen creation

The efficiency of the existing screen creation is improved. Diverting and customizing screens is easy.

  • Gesture screens can be easily created with Drag & Drop.
  • Using grid cell editing you can automatically adjust the object's size and location. Adjustment work of layout change is reduced.
  • Left Navigation is automatically generated. No need to place switches for screen change.
 
 

 

PFXST6200WAD

Standard product information
Family 
HMI
Series 
ST6000 Series
Size 
4" Wide
Model 
PFXST6200WAD
Global Code 
PFXST6200WAD
Product Features 
4" DC Analog
Repair Status 
✔ (Maintenance service is available, able to be maintained.)
Display specifications
Display type 
TFT Color LCD
Display size 
4.3" Wide
Resolution 
480 x 272 pixels
Effective display area 
W95.04 x H53.86 mm [W3.74 x H2.12 in]
Display colors 
16 million colors
Backlight 
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life 
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 25%)
Brightness control 
16 Levels (Adjusted with touch panel or software)
Touch panel type 
Resistive Film (analog, single-touch)
Touch panel resolution 
1,024 x 1,024
Touch panel lifetime 
1,000,000 times or more
Electrical specifications
Rated input voltage 
24 Vdc
Input voltage limits 
19.2 to 28.8 Vdc
Allowable voltage drop 
2 ms or less
Power consumption 
Max. 6.9 W
When power is not supplied to external devices: 3.6 W or less
When screen turns off the backlight (standby mode): 2.8 W or less
In-rush current 
30 A or less
Voltage endurance 
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance 
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)
Environmental specifications
International safety standards 
ce.gifctick.gifeac.gifkc.giful508.gif
Surrounding air temperature 
0 to 50 °C [32 to 122 °F]
Storage temperature 
-20 to +60 °C [-4 to 140 °F]
Ambient humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Storage humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Dust 
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree 
For use in Pollution Degree 2 environment
Corrosive gases 
Free of corrosive gases
Air pressure (altitude range) 
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance 
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance 
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrical fast transient/burst 
IEC 61000-4-4
2 kV: Power port (display unit)
1 kV: Signal ports
Electrostatic discharge immunity 
Contact Discharge Method: 6 kV
Air Discharge Method: 8 kV
(IEC/EN61000-4-2 Level 3)
Memory
Application memory 
When using BLUE:FLASH EPROM 128MB

Removable System: No
Backup memory 
When using BLUE:NVRAM 500KB

Battery: Replaceable battery / Primary battery for clock data backup
Interface specifications
Serial (COM1) 
Asynchronous Transmission: RS-232C / 422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 pin (plug)
USB (Type A) 
Conforms to USB 2.0 (Type A) x 1
Power supply voltage: 5 Vdc ±5 %
Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (micro-B) 
USB 2.0 (micro-B) x 1, Communication Distance: 5 m [16.4 ft]
Ethernet 
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
Structural specifications
Grounding 
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Cooling method 
Natural air circulation
Structure 
IP65F, Type 1, Type 4X (indoor use only), Type 13 (on the front panel when properly installed in an enclosure)*1
External dimensions 
Rear Module: W145.6 x H108.23 xD 41.4 mm [W5.73 x H4.26 x D1.63 in] (excluding protrusions)
Display Module: W201.2 x H137.2 x D17.1 mm [W7.92 x H5.4 x D0.67 in] (excluding protrusions)
Panel cut-out dimensions 
W118.5 x H92.5 mm [W4.67 x H3.64 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]
When using spring clips:
Position 1: 1.5 to 4 mm [0.06 to 0.16 in.]
Position 2: 4 to 6 mm [0.16 to 0.24 in.]*2
Weight 
0.4 kg [0.88 lb] or less

1The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit's level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

2For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

Dimensions
External dimensions 
Panel cut-out dimensions 

A B C
118.5 mm (+1/0 mm)
(4.67 in. [+0.04/0 in.])
92.5 mm (+1/0 mm)
(3.64 in. [+0.04/0 in.])
1.6 to 5 mm
(0.06 to 0.2 in.)

When installing ST-6200WA
with spring clips:
Position 1: 1.5 to 4 mm
(0.06 to 0.16 in.)
Position 2: 4 to 6 mm
(0.16 to 0.24 in.)
External Dimensions with Spring Clips 
External dimensions with cable 
 
 

 

PFXST6400WAD

Standard product information
Family 
HMI
Series 
ST6000 Series
Size 
7" Wide
Model 
PFXST6400WAD
Global Code 
PFXST6400WAD
Product Features 
7" DC Analog
Repair Status 
✔ (Maintenance service is available, able to be maintained.)
Display specifications
Display type 
TFT Color LCD
Display size 
7" Wide
Resolution 
800 x 480 pixels (WVGA)
Effective display area 
W154.08 x H85.92 mm [W6.066 x H3.382 in.]
Display colors 
16 million colors
Backlight 
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life 
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 25%)
Brightness control 
16 Levels (Adjusted with touch panel or software)
Touch panel type 
Resistive Film (analog, single-touch)
Touch panel resolution 
1,024 x 1,024
Touch panel lifetime 
1,000,000 times or more
Electrical specifications
Rated input voltage 
24 Vdc
Input voltage limits 
19.2 to 28.8 Vdc
Allowable voltage drop 
5 ms or less
Power consumption 
Max. 9 W
When power is not supplied to external devices: 5.5 W or less
When screen turns off the backlight (standby mode): 3.6 W or less
In-rush current 
30 A or less
Voltage endurance 
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance 
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)
Environmental specifications
International safety standards 
ce.gifctick.gifeac.gifkc.giful508.gif
Surrounding air temperature 
0 to 50 °C [32 to 122 °F]
Storage temperature 
-20 to +60 °C [-4 to 140 °F]
Ambient humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Storage humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Dust 
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree 
For use in Pollution Degree 2 environment
Corrosive gases 
Free of corrosive gases
Air pressure (altitude range) 
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance 
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance 
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrical fast transient/burst 
IEC 61000-4-4
2 kV: Power port (display unit)
1 kV: Signal ports
Electrostatic discharge immunity 
Contact Discharge Method: 6 kV
Air Discharge Method: 8 kV
(IEC/EN61000-4-2 Level 3)
Memory
Application memory 
When using BLUE:FLASH EPROM 128MB

Removable System: No
Backup memory 
When using BLUE:NVRAM 500KB

Battery: Replaceable battery / Primary battery for clock data backup
Interface specifications
Serial (COM1) 
Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 (plug)
Serial (COM2) 
Asynchronous Transmission: RS-422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, 187,500 bps (MPI), Connector: D-Sub 9 pin (plug)
USB (Type A) 
Conforms to USB 2.0 (Type A) x 1
Power supply voltage: 5 Vdc ±5 %
Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (micro-B) 
USB 2.0 (micro-B) x 1, Communication Distance: 5 m [16.4 ft]
Ethernet 
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 2
Structural specifications
Grounding 
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Cooling method 
Natural air circulation
Structure 
IP65F, Type 1, Type 4X (indoor use only), Type 13 (on the front panel when properly installed in an enclosure)*1
External dimensions 
Rear Module: W145.6 x H108.23 xD 41.4 mm [W5.73 x H4.26 x D1.63 in] (excluding protrusions)
Display Module: W140.4 x H101.1 x D13.9 mm [W5.53 x H3.98 x D0.55 in] (excluding protrusions)
Panel cut-out dimensions 
W190 x H135 mm [W7.48 x H5.31 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*2
Weight 
0.8 kg [1.76 lb] or less

1The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit's level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

2For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

Dimensions
External dimensions 
Panel cut-out dimensions 

A B C
190 mm (+1/0 mm)
(7.48 in. [+0.04/0 in.])
135 mm (+1/0 mm)
(5.31 in. [+0.04/0 in.])
1.6 to 5 mm
(0.06 to 0.2 in.)
External dimensions with cable 
 
 

 

  1. Proface | ST6000 Series | PFXST6500WAD
  2. Proface | ST6000 Series | PFXST6600WAD
  3. Proface | ST6000 Series | PFXST6700WAD
  4. Proface | ST6000 Series | Downloads

Page 25 of 126

  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • Takikawa
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3