SCIENCEGATE

  • Home
  • Products
  • Profile
  • About Us
    • Events
    • Career
  • Contacts
 

Contact Us (65) 6561 0488

Futek LSB200 with Pavone Sistemi DAT1400

 

DAT1400 - THEROTICAL CALIBRATION

 

DAT1400 - CALIBRATION WITH A PROOF WEIGHT

 

The weighing systems are now essential in all industries, from chemical to steel, from food to pharmaceutical, and they make it possible the control and plan the production with an unprecedented accuracy. But weighing systems for the industry does not only consist of devices that perform effectively the weighing process: there are many other instruments, from weight indicators, to transmitters, to dosing/batching tools, which help to complete the framework, allowing the weighing systems to be not only great "scales" but real active components of a production plant.
 
  • DAT 1400

  • DAT 1400 AN/RS485 MOD

  • DAT 1400 Profinet

  • DAT 1400 Ethernet

  • DAT 1400 Ethernet IP

  • DAT 1400 Ethercat


 
 

 

 

MC 355 Touch

Weighing Instrumentation Weight Indicators

DOWNLOADS

 Datasheet 
  • Monochrome LCD display, 5.2" touch screen with backlight, suitable for use with gloves
  • Panel mounting with protection IP65
  • It works both as a weight indicator and as a batcher
  • Handling two measurement channels with simultaneous acquisition
  • Ability to view, during operation, the main status parameters
  • Availability of different serial and analog outputs, as well as logic inputs and outputs, for a complete interfacing with different automation systems
  • Opportunity to interfacing with PC/PLC using protocol comunicaziuone ASCII, Modbus RTU and Profibus DP with optional external module

TECHNICAL CHARACTERISTICS MC 355 TOUCH

Tool voltage: 24 Vdc ±15% 10 W
Temperature range: -10 ÷ +50°C
Storage temperature: -20 ÷ +60°C
Degree of protection: IP65
Trasducer input voltage: 5 Vdc / 120 mA (max 8 cells da 350 Ohm)
Measuring range: 7,8 mV/V bipolar
Input sensitivity: 0.02 microV/per counts
Linearity: <0.01% of full scale
Gain drift: <0.0003% full scale/ °C
Display: LCD 5.2” (visible area 118mm x 58mm) (l x h)
LED status: white, adjustable intensity
A/D Converter: 24 bit
Internal resolution: 16.777.216 counts
Visible resolution: 600.000 divisions displayed on net weight
Divisions value (adjustable): 0.001 ÷ 50
Frequency: 12,5 ÷ 250 Hz
Filter: 0.2 ÷ 50 Hz adjustable
Logic output: 6 optoisolated (clean contact) max 30 Vcc/60 mA cad
Logic input: 6 optoisolated 24 Vcc PNP (external excitation)
Additional I/O: 4 external modules 4 In / 8 Out
Serial door: RS232, RS422, RS485
Baud rate: 1200 ÷ 115200 adjustable
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
FIELDBUS protocol: Profibus DP-V1, baud rate da 9,6 K/sec a 12 Mbit/sec ETHERNET TCP/IP, UDP, ARP, ICMP, ModBus/TCP
Regulatory compliance: EN61000-6-2, EN61000-6-3, EN61010-1
Electrical connection: Screw terminals 5.08 mm
Availability of modules: IN/OUT external, IN/OUT analog, host USB pen drive, Ethernet -option-
 
 

 

 

MC S 302 (ATEX 2,22)

Weighing Instrumentation Atex and Stainless Steel

DOWNLOADS

 Datasheet 
  • Weight indicator and batching process controller -steel, IP66/67 protection-
  • ASCII protocols, Modbus-RTU and Ethernet TCP-IP
  • PROFIBUS and DeviceNet optional interfaces
  • Weight control, up to 50 batching recipes (recalled from the keyboard)
  • Fiscal memory (Alibi Memory)
  • Automatic prints
  • ATEX certification, IP65, 2.22 (OPTION)
  • Flush, wall, column or desktop mounting

TECHNICAL CHARACTERISTICS MC S 302 (ATEX 2,22)

Trasducer input voltage: 5 V (max 8 celle da 350 Ohms)
Measuring range: -3.9 ÷ +3.9 mV/V
Input sensitivity: 0.02 µV/ per count
Linearity: <0.01% of full scale
Gain drift: <0.0003% full scale/ °C
A/D Converter: 24 bit
Visible resolution: 600.000 divisions displayed on net weight
Divisions value (adjustable): x1, x2, x5
Set decimal: 0.0 ; 0.00 ; 0.000; 0.0000
Filter: 0.2 ÷ 50 Hz. 100 Hz during dosage
Tool voltage: 230 Vac ±10% - 50/60 Hz absorbed power 7 VA (115 Vac on demand)
Temperature range: -10 ÷ +40°C
Storage temperature: -20 ÷ +50°C
Logic output: 6 relays (NA) MAX 115 Vac /30 Vdc 0.5 A cad.
Logic input: 8 optoisolated 12 / 24 Vcc PNP
Serial door: COM1: RS232 half duplex max 15m COM2: RS422/RS485 half duplex max 1000m
FIELDBUS protocol: ASCII, Modbus RTU, baud rate 1200 ÷ 115K adjustable
Regulatory compliance: EN61326, and EN61010-1
ATEX II 3 GD EEx nR IIC IP65 T6: EN 13463-1: 2003; EN 60529: 1991 + A1: 2000 IEC 60079-0: 2004; IEC 60079-15: 2005
Optional dosage software: up to 12 components with external module with 8 relays aggregation of component values ​​and recipe. Management and inventory control. Max 50 programmable recipes
Analog optional output: Optically isolated 16-Bit Voltage: 0 to 5 or 0 to 10V (R> 10 Ohms); Current: 0 to 20 or 4 ÷ 20mA (R <300 Ohms); Linearity 0.03% of full scale; Temperature drift 0.001% of full scale /°C
Optional fieldbus avaiable: Profibus DP, DeviceNet and ETHERNET TCP-IP external mounting on DIN guide
 
 

 

 

E 90/1

Weighing Instrumentation Atex and Stainless Steel

DOWNLOADS

 Datasheet 
  • Designed for installation in potentially explosive environments
  • Complete digital programming of the instrument directly from the front 
  • RS232 or RS422/RS485, MODBUS RTU or ASCII protocols
  • Instrument suitable for use in many applications required by most industries in the chemical, pharmaceutical and paint
  • Intrinsically safe barriers housed into the deflagration case
  • The instrument E 90/1 can be interfaced with most popular PLCs via Profibus-DP -installable as an option directly in the instrument

TECHNICAL CHARACTERISTICS E 90/1

Transducer power supply: max 5 V (max 6 cells of 350 Ohms) through intrinsic safety barriers
Measuring range: from transducers with sensitivity from 0.5 to +3.5 mV/V
Input sensitivity: 0.02 micronV/division
Linearity: <0.01% of full scale
Thermal drift: <0.001% of full scale /°C
A/D converter: 24 bits
VIewable resolution: 60.000 displayable divisions on the net weight
Settable decimals: 0.0; 0.00; 0.000
Filter: selectable from 0.1 to 25 Hz
Keyboard: 4 buttons running EX
Power supply: 24 VDC ± 15% - power consumption 5W or 115/230 Vac with integrated power supply
Temperature range: -10 To +50 ° C (max 85% humidity non-condensing)
Storage temperature: -20 ÷ +70 °C
Logic outputs: 2 relays (contact) MAX 24 Vcc/100 mA cad
Logic inputs: 2 opto-isolated 24 Vcc PNP (external power supply)
Serial port: RS232C or RS422/RS485
Transmission distance: 15m (RS232C), 100m (RS422 and RS485)
Standard protocol: ASCII, MODBUS RTU
Peak Hold Function for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 selectable
Regulatory compliance: EN50081-1, EN5002-2 for EMC;
  EN61010-1 for Electrical Safety
  94/9/EC for ATEX II 2 GD; EEx d IIB T6÷T4
Manual batching: a single component in loading or unloading
Fieldbus connection option: Profibus-DP with integrated board
Analog output: 16-bit
  Voltage: 0 to 10 V and 0 to 5 V (R min 10k Ohms)
  Power: 0 to 20 mA, 4 to 20 mA (R max 300 Ohms)
 
 

 

 

E 70/2

Weighing Instrumentation Atex and Stainless Steel

DOWNLOADS

 Datasheet 
  • Designed for installation in potentially explosive environments
  • Complete digital programming directly from the front of the instrument
  • RS232 or RS422/RS485, MODBUS RTU or ASCII protocols
  • Suitable for satisfying various needs in the field of industrial weighing: management of level limits, weight control and elaborate dosing procedures
  • Calibration run with certificates of transducers
  • Housing in explosion proof case -also intrinsically safe barriers- as an interface with the load cells
  • Degree of protection IP65/IP66

TECHNICAL CHARACTERISTICS E 70/2

Transducer power supply: max 5 V (max 6 cells of 350 Ohms) through intrinsic safety barriers
Measuring range: from transducers with sensitivity from -3.9 to +3.9 mV / V
Input sensitivity: 0.02 micronV/division
Linearity: <0.01% of full scale
Thermal drift <0.0003% of full scale / ° C
Display: 7 digit, 7-segment red LED, height 14mm
A/D converter: 24 bits
Internal resolution: > of 16,000,000 points
Viewable resolution: 60,000 displayable divisions on the net weight
Settable decimals: 0.0; 0.00; 0.000
Filter: selectable from 0.2 to 50 Hz
Keyboard: 14 buttons in ATEX execution
Power supply: 230 Vdc 50/60 Hz (optional 115 Vdc) max absorption 15VA
Temperature range: -10 To +50 ° C (max 85% humidity non-condensing)
Storage temperature: -20 ÷ +70 °C
Logic outputs: 6 relays (contact) MAX 115Vac/30 Vdc, 0.5 A each
Logic inputs: 6 opto-isolated 12 V cc PNP
Serial port: RS232C or RS422/RS485
Transmission distance: 15m (RS232C), 100m (RS422 and RS485)
Standard protocol: ASCII, MODBUS RTU
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 115200 selectable
Regulatory Compliance: EN50081-1, EN5002-2 for EMC;
  EN61010-1 for Electrical Safety
  94/9/EC for ATEX II 2 GD; EEx d IIB T6÷T4
 
 

 

  1. Pavone | Atex and Stainless Steel | DAT S 400
  2. Pavone | Atex and Stainless Steel | MCT S 1302
  3. Pavone | Crane Scales | PSMC
  4. Pavone | Crane Scales | CS05

Page 11 of 17

  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2026. ALL RIGHTS RESERVED.