SCIENCEGATE

  • Home
  • Products
  • Profile
  • About Us
    • Events
    • Career
  • Contacts
 

Contact Us (65) 6561 0488

 

MCT 1302 Setting with Tester 1006

 

Tester 1006 Theoretcal Calibration

 

Tester 1006 Weighing System Testing

 

TESTER 1006

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • For the simultaneous control of up to 4 load cells in any weighing system
  • Direct operation as Calibrator and peak detector
  • Upload and download function for programming tools and DAT series MC 302
  • For the correct mechanical installation and fault diagnosis
  • Comes with cable for connection to our junction boxes / sum mod. CEM 4 / C and CGS 4 / C
  • The simultaneous display of each individual load cell signal is used to control the entire weighing system, the weight distribution, overloads, the faulty cells or faulty connections

TECHNICAL TESTER 1006

Encoder supply: 5 VDC / 60 mA (max 4 x 350 ohm cells in parallel)
Measuring range: from -3.9 to +3.9 mV / V
Linearity: <0.01% of full scale
Temperature drift: <0.001% FS / ° C
Display: Chart 3 "
A / D converter: 24 bits
Internal resolution: > 16,000,000 points
Viewable resolution: 50,000 divisions
Divisions value (selectable): x1, x2, x5
Settable decimal: 0.0; 0.00; 0,000
Keyboard: 16 buttons + on / off
Power tool: 4 AA batteries - Power consumption 5 W
Absorption: 125 ÷ 190 mA
Autonomy: about 4 hours with alkaline batteries, about 8 hours with rechargeable Ni-MH 1.2 V (2000 mAh)
Operating temperature: -10 To +50 ° C (max 85% humidity non-condensing)
Storage temperature: -20 To +70 ° C
Degree of protection: IP54
Weight: 500 g approx
Connections to the load cells: Sub-D 25-pin connector and its cable length 2m
Tools connections: Sub-D 25-pin connector and cable length 0.5m
CALIBRATOR  
Precision: 0.033% of FS
Supply voltage cells: 3 ÷ 12 Vdc
Signal: -3 ÷ +20.3 mV
Impedance: Selectable 350/700 Ohm, or set 300 to 4500 Ohm
 
 

 

 

AD SYSTEM

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • The ADVANCED DIGITAL SYSTEM allows the digital management of analog load cells
  • RS232 and RS422 / RS485 output, ASCII protocol or MODBUS RTU; Optional Protocols: PROFIBUS, DEVICENET and ETHERNET
  • Maximum displayed weight: up to 600,000 divisions on payload
  • The ADVANCED DIGITAL SYSTEM consists of two elements: the special junction box and the reading instrument

AD SYSTEM SPECIFICATIONS

transducers Power:

5 V (short circuit protected)
Measuring range: from -1.0 to +3.5 mV / V
Input sensitivity: 12:02 micronV / Division
Linearity: ± 0.01% of FS
Thermal drift: ± 0.001% FS / ° C
Display: LCD, alphanumeric
A / D converter: 24 bits (over 16,000,000 divisions)
Conversion speed A / D: from 6 to 12 updates per second on each cell (it depends on the n ° of cells)
Filter: selectable from 0.1 to 25 Hz
Calibration: with test certificates, sample weights table
Keyboard: 4 membrane keys
Power tool: 24 Vdc ± 15% - Absorbed Power 10W
Operating temperature: -10 to +50 ° C
Storage temperature: -20 to +70 ° C
Logic outputs: 2 relays (dry contacts NA) -115 Vac / 30 Vdc 0.5 A
Logic inputs: 2 optoisolated 24 VDC PNP
Serial port: RS232 or RS422 / RS485
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Fieldbus protocol: PROFIBUS, DEVICENET, ETHERNET (optional)
Standard protocol: ASCII, Modbus RTU
Baud rate: 1200 ÷ 115200 selectable
Optional analog output: optoisolated to 16 Bit. Voltage: 0 ÷ 5 / 10V (R min10 K Ohm). Current: 0/4 ÷ 20mA (R max 300 Ohm)
Regulatory Compliance: EN61000-6-2, EN61000-6-3
 
 

 

 

AND LINK 3000

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • 5 different electronic configurations
  • 5 different cases for all system requirements
  • And remote diagnostics from field failures
  • Remote configuration from PC (through dedicated software) or directly from the Master via the communication protocol used
  • Integrated into any industrial control and supervision system
  • Faulty cell emulation (exclusion from the weighing system with automatic re-calibration)
  • Troubleshooting on the load cells via local diagnosis and remotized

TECHNICAL FEATURES AND LINKS 3000

Operating temperature: -10 To + 50 ° C
Storage temperature: -20 To +70 ° C
Power to the Board: 12 to 24 VDC
Load cell supply: 5 Vdc
input signal cells: measurement range of -5 mV / V to + 5mV / V
A / D converter: 24 bits
Internal resolution: > 16,000,000 points
Resolution 2 mV / V: > 3,000,000 points on each cell channel
input sensitivity: 0003 micronV / Division
Readings per second per cell: from 0.1 to 72 based on the number of activated cell channels and the digital filter value
Linearity: > 12:01% FS
Temperature drift: > 0.003% FS / ° C
Serial Ports: COM1: RS232 (for PC configuration parameters)
  COM2: RS485 Modbus RTU protocol
  Profibus-DP
  DeviceNet
  CANOpen
  Modbus TCP over Ethernet
Electric connections: Load Cele: removable terminal blocks 7-pin 5mm diam
  Power: 7-pin removable terminal diam 5mm
  Profibus-DP: D-sub 9-pin connector
  DeviceNet: 5-pin removable terminal blocks
  CANOpen: D-sub 9-pin connector
  Ethernet: RJ-45 connector
dimensions: 130x100x60 mm (WxHxD) of carrier board for DIN rail
CE conformity: EN 61000-6-3, EN 61000-6-2
 
 

 

 

I-Box 2000

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • For weighing systems based on strain gauge load cells
  • It allows the continuous control of the individual load cells
  • The effective economic alternative to digital load cells
  • It replaces the analog trunk cards
  • It simplifies installation and accelerates the calibration of the system
  • It provides weight and the output signal of each individual cell to correct weight distributions on the load cells
  • A dedicated for PC software allows you to program the operating parameters, monitors each channel and displays the weight values

SPECIFICATIONS I-BOX 2000

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: from -0.5 to +3.5 mV / V (optional from -3.9 to +3.9 mV / V)
Input sensitivity: 00:03 MicroV / Division
Linearity: <0.01% of full scale
Thermal drift: <0.0003% of full scale / ° C
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
N ° readings per second: 0.1 ÷ 72 based on the number of active channels and digital filter
Power tool: 12 to 24 VDC or 5 VDC on request
Operating temperature: -10 / + 50 ° C
Serial port: COM1: RS232 (for distances up to 15m) COM2: RS485 (for distances up to 1000m)
Dimensions: Card: 128 x 72 x 20 (L x W x H) - ABS case: 200 x 150 x 75 (L x W x H) - metal housing: 160 x 160 x 90 (L x W x H)
CE conformity: EN 61000-6-3, EN 61000-6-2
 
 

 

 

UWT 600

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • DIN rail mounting
  • RS232 and RS422 / RS485 output, ASCII protocol or MODBUS RTU
  • High performance and reliability
Options:
  • PROFIBUS, DeviceNet, Ethernet
  • Analog output
  • Ability to configure the instrument with two options simultaneously

SPECIFICATIONS UWT 600

transducers Power:

5 V (max 8 350 Ohm cells)
Measuring range: ÷ -1.5 +3.5 mV / V
Input sensitivity: 00:02 MicroV / Division
Linearity: ± 0.01% SN
Thermal drift: SN ± 0.001% / ° C
Display: LCD, alphanumeric, backlit, 2 rows x 16 characters
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 600,000 divisions
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable 0.1 to 25 Hz
Keyboard: 4 membrane keys
Power tool: 24 Vdc ± 15% - 12 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 70 ° C
Logic outputs: 2 relays (contacts cleaned NA) - 115 VAC / 30 VDC, 0.5 A
Logic inputs: 2 optoisolated 24 VDC PNP
Serial port: COM1: RS232 COM2: RS422 / RS485
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Fieldbus protocol: PROFIBUS, DEVICENET, ETHERNET (optional)
Serial protocol: ASCII, Modbus RTU
Baud rate: 1200 ÷ 115200 selectable
Analogue output (optional): optoisolated 16-Bit Voltage: 0 ÷ 5 / 10V (R min10 K Ohm), Current: 0/4 ÷ 20mA (R max 300 Ohm)
Regulatory Compliance: EN61000, EN61000 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions: 100 x 75 x 110 mm (L x H x D)
 
 

 

  1. Pavone | Weight Transmitters | DAT 400 PBL
  2. Pavone | Weight Transmitters | DAT 400 PBS
  3. Pavone | Weight Transmitters | DAT 500/DEVICENET
  4. Pavone | Weight Transmitters | DAT 500/PROFINET

Page 14 of 17

  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2026. ALL RIGHTS RESERVED.