SCIENCEGATE

  • Home
  • Products
  • Profile
  • About Us
    • Events
    • Career
  • Contacts
 

Contact Us (65) 6561 0488

 

DAT 200/PROFIBUS

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • High performance and long-term reliability
  • Mounting "snap-on" DIN rail (EN50022)
  • Fieldbus: PROFIBUS DP 
  • Configuration and calibration from the front panel
  • Calibration certificates executable with the transducers, or with known weights
  • RS232 serial output, ASCII protocols
  • Connects directly to the Profibus DP fieldbus
  • The width dimensions allow to place a large number of transmitters within the electrical automation panels
  • Interfacing with barriers Intrinsically Safe for use in hazardous areas

TECHNICAL DAT 200 / PROFIBUS

transducers Power:

4 V (max 4 x 350 ohm cells)
Measuring range: -4 to +4 mV / V
Input sensitivity: 00:02 V / division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 5 digits, red 7-segment LED, height 7 mm
Status LEDs: 2 red
A / D converter: 24-bit
Internal resolution: of 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions Value: 0001 ÷ 50 selectable
Filter: 0.02 to 25 Hz Selectable
Keyboard: 3 mechanical buttons (behind the red door)
Power tool: 24 Vdc ± 10% - input power 2 W
Operating temperature: -10 / + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 / + 60 ° C
Serial port: RS232 half duplex with ASCII protocol
Baud rate: 2400 ÷ 115200 Selectable
Transmission distance: 15 m
Direct protocol to fieldbus: Profibus DP-V1
Baud rate: 9.6 K / sec to 12 Mbits / sec
Regulatory Compliance: EN61000-6-2, EN61000-6-3 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw pitch 5.08 mm, D-Sub connector 9-pin female
 
 

 

 

DAT 100/ANALOG

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • High performance and long-term reliability
  • Mounting "snap-on" DIN rail (EN50022)
  • ANALOG Output  
  • Configuration and calibration executable from the front panel with the certificates of the transducers, or with known weights
  • 2 logic inputs and 2 outputs Relay 
  • RS232 serial outputs, ASCII and Modbus RTU protocols 
  • The width dimensions allow to place a large number of transmitters within the electrical automation panels
  • Interfacing with barriers Intrinsically Safe for use in hazardous areas

TECHNICAL DAT 100 / ANALOG

transducers Power:

4 V (max 4 x 350 ohm cells)
Measuring range: -4 to +4 mV / V
Input sensitivity: 00:02 V / division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 5 digits, red 7-segment LED, height 7 mm
Status LEDs: 2 red
A / D converter: 24-bit
Internal resolution: of 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): 0001 ÷ 50
Filter: selectable 0.2 to 25 Hz
Keyboard: 3 mechanical buttons (behind the red door)
Power tool: 24 Vdc ± 10% - input power 2 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 60 ° C
Logic outputs: 2 optisolate; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial Ports: RS232 half duplex with ASCII protocol or Modbus RTU full duplex RS485 with ASCII protocol or Modbus RTU
Baud rate: 2400 ÷ 115200 Selectable
Transmission distance: 15 m
Analog output: optoisolated to 16 Bit
Voltage: 0 ÷ 5 / 10V (R min10 K Ohm)
Current: 0/4 ÷ 20mA (R max 300 Ohm)
Linearity: <0,03% FS
Thermal drift: <0.002% FS
Regulatory Compliance: EN61000-6-2, EN61000-6-3 EMC; EN61010-1 for Electrical Safety
Electric connections: Screw terminal blocks 5.08 mm pitch
 
 

 

 

DAT 100/RS485

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • High performance and long-term reliability
  • Mounting "snap-on" DIN rail (EN50022)
  • Configuration and calibration executable from the front panel with the certificates of the transducers, or with known weights
  • RS232 and RS485 outputs, ASCII and Modbus RTU protocols 
  • The width dimensions allow to place a large number of transmitters within the electrical automation panels
  • Interfacing with barriers Intrinsically Safe for use in hazardous areas

TECHNICAL DAT 100 / RS485

transducers Power:

4 V (max 4 x 350 ohm cells)
Measuring range: -4 to +4 mV / V
Input sensitivity: 00:02 V / division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 5 digits, red 7-segment LED, height 7 mm
Status LEDs: 2 red
A / D converter: 24-bit
Internal resolution: of 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): 0001 ÷ 50
Filter: selectable 0.2 to 25 Hz
Keyboard: 3 mechanical buttons (behind the red door)
Power tool: 24 Vdc ± 10% - input power 2 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 60 ° C
Logic outputs: 2 optisolate; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial Ports: RS232 half duplex with ASCII protocol or Modbus RTU full duplex RS485 with ASCII protocol or Modbus RTU
Baud rate: 2400 ÷ 115200 Selectable
Transmission distance: 15 m (RS232); 1000 m (RS485)
Regulatory Compliance: EN61000-6-2, EN61000-6-3 EMC; EN61010-1 for Electrical Safety
Electric connections: Screw terminal blocks 5.08 mm pitch
 
 

 

 

AT10

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • DIN rail mounting
  • Terminal 20-pin for the 4 load cells connection
  • Power supply 20 ÷ 28 Vdc
  • Input signal from 3 to 30mV
  • Adjustment Zero and Full Scale by dip-switch and multi-turn trimmer

TECHNICAL SPECIFICATIONS AT10

Power supply:

24 Vdc ± 15%
Cells Power: 10 Vdc (max 4 x 350 ohm cells)
Maximum power: 6 W
Analog outputs: 0 to 5 VDC, 0 to 10 VDC, 0 to 20 mA, 4 ÷ 20 mA
Full scale (FS): 3 ÷ 30 mV / V
Linearity: ± 0.02% FS
Operating temperature: -10 to +50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 to +70 ° C
Thermal stability: 20 ppm / ° C
Temperature drift: 0.005% FS / ° C
Zero Calibration: Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Calibration of full scale (fs): Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Analog filter (for V output only): Adjustable through trimmer monoturn 270 ° C
Mounting: DIN rail
Dimensions: 133 x 92 x 56 mm (L x H x D)
Connections: Screw terminal blocks 5.08 mm pitch
CE conformity: EN50081-1, EN5002-2 EMC, LVD EN61010-1
Options: Power supply 115 or 230 VAC 50/60 Hz (for DIN rail)
 
 

 

 

AT08

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • DIN rail mounting
  • Ideal for applications with a minimum tare weight of the system, such as platforms or pressure transducers
  • Power supply 20 ÷ 28 Vdc
  • Input selectable between 10, 20 and 30 mV
  • Adjustment Zero and Full Scale by dip-switch and multi-turn trimmer

TECHNICAL SPECIFICATIONS AT08

Power supply:

24 Vdc ± 15%
Cells Power: 10 VDC / 120 mA (max 4 x 350 ohm cells)
Maximum power: 5 W
Analog output: 0 ÷ 10 Vdc bipolar, 0 to 20 mA or 4 ÷ 20 mA
Maximum input signal: selectable between 10 mV, 20 mV and 30 mV
Linearity: ± 0.02% FS
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 70 ° C
Temperature drift: 0.005% FS / ° C
Zero Trim: Through 20 RPM trimmer (-8% to + 3% FS)
Calibration of the full scale (FS): Through 20 RPM trimmer (± 5% FS)
Analog filter (for V output only): Adjustable through trimmer monoturn 270 ° C
Response time (analog filter): 5 ÷ 250 ms. (Fixed at 5 ms of mA output)
Mounting: DIN rail
Dimensions: 78 x 92 x 52 mm (L x H x D)
Connections: Screw terminal blocks 5.08 mm pitch
Number of connectable cells: up to 4 load cells
CE conformity: EN50082-2, EN55011, EN61000
Options: Power supply 115 or 230 VAC 50/60 Hz (for DIN rail) Power supply 12 Vdc ± 15% (available output 0 ÷ 5 Vdc bipolar) analog filter with response time 0.5 ÷ 25 ms
 
 

 

  1. Pavone | Weight Transmitters | AC1500
  2. Pavone | Weight Transmitters | DAT 1400 ETHERCAT
  3. Pavone | Weight Transmitters | DAT 1400 ETHERNET IP
  4. Pavone | Weight Transmitters | DAT 1400 ETHERNET

Page 16 of 17

  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3