DAT 500/ANALOG

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • Output RS232 or RS422 / RS485, MODBUS RTU or ASCII protocols
  • High performance and reliability
  • Upload and download function for programming with TESTER 1006
  • The connection can also occur through the external converter
  • Linearisation 10 points
  • Calibration executable with the transducers Certificates
  • Configuration and calibration from the front or from PC via RS232 / RS485 serial port with Inovation ™ program
  • (MS Windows)

TECHNICAL DAT 500 / ANALOG

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: from -0.5 to +3.5 mV / V (optional from -3.9 to +3.9 mV / V)
Input sensitivity: 00:02 MicroV / Division
Linearity: <0.01% of full scale
Thermal drift: <0.001% of full scale / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable from 0.1 to 25 Hz
Power tool: 24 VDC ± 15% - absorbed power 5 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 70 ° C
Logic outputs: 2 optisolate; MAX 24 V DC / 100 mA each.
Logic inputs: 2 optoisolated 24V dc PNP (external power supply)
Serial port: RS232C or RS422 / RS485 Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 Selectable
Analog output: optoisolated 16-Bit Voltage: 0 ÷ 5 / 10V (R min10 K Ohm), Current: 0/4 ÷ 20mA (R max 300 Ohm)
Regulatory Compliance: EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions and weight: 96 x 48 x 120 mm (L x H x P); 250 g
BCD Output: optional
Optional Bipolar output: bipolar version ± 10V
 
 

 

 

DAT 500

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • Output RS232 or RS422 / RS485, MODBUS RTU or ASCII protocols
  • High performance and reliability
  • Upload and download function for programming with TESTER 1006
  • The connection can also occur through the external converter
  • Linearisation 10 points
  • Calibration executable with the transducers Certificates
  • Configuration and calibration from the front or from PC via RS232 / RS485 serial port with Inovation ™ program
  • (MS Windows)

TECHNICAL DAT 500

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: from -0.5 to +3.5 mV / V (optional from -3.9 to +3.9 mV / V)
Input sensitivity: 00:02 MicroV / Division
Linearity: <0.01% of full scale
Thermal drift: <0.001% of full scale / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable from 0.1 to 25 Hz
Power tool: 24 VDC ± 15% - absorbed power 5 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 70 ° C
Logic outputs: 2 optisolate; MAX 24 V DC / 100 mA each.
Logic inputs: 2 optoisolated 24V dc PNP (external power supply)
Serial port: RS232C or RS422 / RS485 Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 Selectable
Regulatory Compliance: EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions and weight: 96 x 48 x 120 mm (L x H x P); 250 g
Optional Bipolar output: bipolar version ± 10V
 
 

 

 

DAT 400 THEORETICAL CALIBRATION

 

DAT 400 CALIBRATION WITH A PROOF WEIGHT

 

DAT 400/DEVICENET

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • WORLD EXCLUSIVE Pavone systems, high performance and reliability
  • Upload and download function for programming with TESTER 1006
  • Also available with DEVICENET 
  • Linearisation 10 points
  • Calibration executable with the transducers Certificates
  • Configuration and calibration from the front panel or from PC via USB

TECHNICAL DAT 400 / DEVICENET

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: ÷ -0.5 +3.5 mV / V (optional ÷ -3.9 +3.9 mV / V)
Input sensitivity: 00:02 MicroV / Division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable 0.1 to 25 Hz
Keyboard: 4 keys tactile feedback disabilitabili
Power tool: 24 Vdc ± 15% - absorbed power 5 W
Operating temperature: -10 / + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 / + 70 ° C
Logic outputs: 2 optoisolated; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial port: USB, RS-232 with Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 selectable (RS232)
Regulatory Compliance: EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions and weight: 106 x 90 x 58 mm (L x H x P); 250 g
Communication protocols: DEVICENET
 
 

 

 

DAT 400 THEORETICAL CALIBRATION

 

DAT 400 CALIBRATION WITH A PROOF WEIGHT

 

DAT 400/PROFINET

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • WORLD EXCLUSIVE Pavone systems, high performance and reliability
  • Upload and download function for programming with TESTER 1006
  • Connects directly to the fieldbus with TCP protocols, ModuBus / TCP, UDP, IP, ICMP, ARP
  • Also available with PROFINET
  • Linearisation 10 points
  • Calibration executable with the transducers Certificates
  • Configuration and calibration from the front panel or from PC via USB 

TECHNICAL DAT 400 / PROFINET

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: ÷ -0.5 +3.5 mV / V (optional ÷ -3.9 +3.9 mV / V)
Input sensitivity: 00:02 MicroV / Division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable 0.1 to 25 Hz
Keyboard: 4 keys tactile feedback disabilitabili
Power tool: 24 Vdc ± 15% - absorbed power 5 W
Operating temperature: -10 / + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 / + 70 ° C
Logic outputs: 2 optoisolated; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial port: USB, RS-232 with Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 selectable (RS232)
Regulatory Compliance: EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions and weight: 106 x 90 x 58 mm (L x H x P); 250 g
Communication protocols: PROFINET
 
 

 

 

DAT 400 THEORETICAL CALIBRATION

 

DAT 400 CALIBRATION WITH A PROOF WEIGHT

 

DAT 400/ETHERNET

Weighing Instrumentation Weight Transmitters

DOWNLOADS

 Datasheet 
  • WORLD EXCLUSIVE Pavone systems, high performance and reliability
  • Upload and download function for programming with TESTER 1006
  • Connects directly to the fieldbus 10/100 Ethernet with TCP protocols, ModuBus / TCP, IP 
  • Linearisation 10 points
  • Calibration executable with the transducers Certificates
  • Configuration and calibration from the front panel or from PC via USB

TECHNICAL DAT 400 / ETHERNET

transducers Power:

5 V (max 6 350 Ohm cells)
Measuring range: ÷ -0.5 +3.5 mV / V (optional ÷ -3.9 +3.9 mV / V)
Input sensitivity: 00:02 MicroV / Division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5
Set Decimal: 0.0; 0:00; 0000
Filter: selectable 0.1 to 25 Hz
Keyboard: 4 keys tactile feedback disabilitabili
Power tool: 24 Vdc ± 15% - absorbed power 5 W
Operating temperature: -10 / + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 / + 70 ° C
Logic outputs: 2 optoisolated; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial port: USB, RS-232 with Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 selectable (RS232)
Regulatory Compliance: EN61326-1, EN55011 and EN55014 EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm
Dimensions and weight: 106 x 90 x 58 mm (L x H x P); 250 g
Communication protocols: 10/100 Ethernet with TCP protocols, ModuBus / TCP, IP
 
 

 

  1. Pavone | Weight Transmitters | DAT 400/PROFIBUS DP
  2. Pavone | Weight Transmitters | DAT 400/ANALOG
  3. Pavone | Weight Transmitters | DAT 400
  4. Pavone | Weight Transmitters | DAT 200/PROFINET

Page 15 of 17

  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

Brands

  • BeanAir
  • Control Techniques
  • Delphin
  • Exemys
  • Flowline
  • Futek
  • Hakko
  • Kansai
  • KARI
  • LCM System
  • Micro Epsilon
  • MIRUS
  • Pavone
  • Proface
  • Solartron Metrology
  • STS
  • VALCOM

About Us

  • Events
  • Career
  • Download
  • Contacts
bizSAFE3
PGO9
 

SCIGATE AUTOMATION (S) PTE LTD @ 2026. ALL RIGHTS RESERVED.