AT/P Series Analogue Pneumatic Push Probe - Specification
AT/P Series |
Axial Cable Outlet (LVDT) |
AT/1/P |
AT/1.5/P |
AT/2.5/P |
AT5/1/P |
AT/5/P |
AT/10/P |
Radial Cable Outlet (LVDT) |
ATR/1/P |
ATR/1.5/P |
ATR/2.5/P |
|
ATR/5/P |
ATR/10/P |
Axial Cable Outlet (Half Bridge) |
AT/1/PH |
AT/1.5/PH |
AT/2.5/PH |
AT5/1/PH |
AT/5/PH |
AT/10/PH |
Radial Cable Outlet (Half Bridge) |
ATR/1/PH |
ATR/1.5/PH |
ATR/2.5/PH |
|
ATR/5/PH |
ATR/10/PH |
Body Diameter |
8h6 |
Measurement Range (mm) |
± 1.0 |
± 1.5 |
± 2.5 |
± 1.0 |
± 5.0 |
± 10.0 |
Pre-Travel (mm) |
0.15 |
Over Travel (mm) |
0.85 |
8.85 |
0.85 |
Accuracy (% of reading or µm, whichever greater) |
0.5, 1.0 µm |
0.5, 1.5 µm |
0.5, 2.5 µm |
0.5, 1.0 µm |
0.5, 5.0 µm |
0.7, 10.0 µm |
Repeatability (µm) |
<0.15 |
Tip Force (N) at Centre Travel ± 20% |
0.18 @ 0.3 bar
1.1 @ 1 bar |
0.18 @ 0.3 bar
1.1 @ 1 bar |
0.18 @ 0.3 bar
1.1 @ 1 bar |
0.18 @ 0.3 bar
1.1 @ 1 bar |
0.18 @ 0.3 bar
1.1 @ 1 bar |
0.18 @ 0.3 bar
1.1 @ 1 bar |
Resolution |
Dependent on electronics |
Temperature Coefficient (% FS/°C) |
0.01 |
|
Electrical Interface |
LVDT Plugged |
Sensitivity1(mV/V/mm) ± 0.5% |
200 |
133 |
80 |
200 |
40 |
20 |
Energising Current (mA/V ± 5%) |
1.8 |
2.0 |
2.0 |
1.8 |
2.0 |
1.0 |
LVDT Unplugged |
Sensitivity (mV/V/mm) ± 5% |
210 |
150 |
150 |
210 |
105 |
33 |
Half Bridge Plugged |
Sensitivity1(mV/V/mm) ± 0.5% |
73.5 |
49.0 |
29.4 |
73.5 |
14.7 |
7.35 |
Energising Current (mA/V ± 5%) |
1.0 |
1.0 |
1.0 |
1.0 |
1.2 |
1.2 |
Half Bridge Unplugged |
Sensitivity ± 5% |
83 |
150 |
150 |
210 |
105 |
33 |
1Linearity and Sensitivity error combined does not exceed a total of 0.5%. |
Environmental |
Storage Temperature (°C) |
-40 to +100 |
Operating Temperature (°C) |
-10 to +80 |
IP Rating |
None |
|
Materials |
Case |
Stainless Steel |
Probe Tip |
Nylon and Tungsten Carbide |
Gaiter |
None |
Cable |
2 m PUR |
|
|
|
|
|
|
|
LVDT Sensor | Low Tip Force Inductive Sensors
Solartron Metrology contact gauging probes, LVDT probes or displacement sensors provide the gauge builder with the most cost effective solution for a range of dimensional precision measurement and positioning applications.
Feather Touch LVDT Probes have been designed to gauge delicate surfaces such as glass, thin sections, pharmaceutical products and tiny electro mechanical components. Whereas the traditional LVDT gauging probe exerts a force of 0.7N, the LVDT Feather Touch probe, when operated horizontally, exerts a mere 0.18N. This is achieved by replacing the naturally elastic gaiter with a close tolerance gland. On pneumatic versions of the LVDT probe air leakage through this gland is less than 2.5ml per second at 1 bar pressure, avoiding surface contamination while still providing a degree of cleaning the probe bearing.
Buy your LVDT sensor from Solartron Metrology and be sure that you are getting an LVDT sensor that is a result of 40 years continual improvement from our experienced design engineers, manufactured solely in our dedicated ISO9001 accredited factory in the UK.

|
|
 |
|
-
Standard contact sensor tip force of 0.18N (options available)
-
± 1, ± 2,5, ± 5, ± 10 mm displacement transducer measuring ranges
-
Linearity better than 0.5% of precision measurement
-
Repeatability precision better than 0.05 µm
-
Range of contact sensor tips available
-
Pneumatic actuation
-
IP50 sealing (fully sealed options available)
-
Inductive sensors with excellent sideload capability
-
Linear Variable Differential Transformer (LVDT) or Half Bridge options
-
Displacement sensors available with vacuum retract
|
|
|
|
 |
|
|
|
Replacement Gaiters |

Gaiters can be replaced when damaged. Only pneumatic push probes require gaiter rings.
Part Numbers:
Spring Push |
|
Part Number |
Pneumatic Push |
Part Number |
A6G/1/S |
D6P/2/S |
205014 |
|
|
|
AX/1/S |
DP/2/S |
204851 |
AX/1/P |
DP/2/P |
802691 |
AX/1.5/S |
|
204851 |
|
|
|
AX/2.5/S |
DP/5/S |
204894 |
AX/2.5/P |
DP/5/P |
802692 |
AX/5/S |
DP/10/S |
204860 |
AX/5/P |
DP/10/P |
802693 |
AX5/1/S |
DP10/2/S |
204860 |
AX5/1/S |
DP10/2/P |
802693 |
|
DP/12/S |
209562 |
|
DP/12/P |
|
AX/10/S |
DP/20/S |
205906 |
AX/10/P |
DP/20/P |
803235 |
|
|
|
|
|
|
|
LE/12/S |
209562 |
|
LE/12/P |
805098 |
|
LE/25/S |
205906 |
|
LE/25/P |
804241 |
|
Clamping Collet |
Ø9.5 mm |
Ø10 mm |
805048 (M4 Screw)
806788 (M3 Screw)
|
806460-SX (M4 Screw) |

|

|
For use with all 8 mm clamping shaft sensors. The clamping collet distributes the clamping forces evenly around the shaft. Using the supplied grub screw, the probe can be loosened while holding the collet in place. |
Extension Cables Analogue |

Extension cables for analogue sensors with 5 pin DIN 240 ° connectors are available for LVDT and Half Bridge types.
|
Probe Tips |
Various probes are available. |
Imperial Adapter Sleeves |

Adapter Sleeves can be used to increase the body diameter of 8 mm sensors to 9.512 (3/8"). Available in lengths A from 12 to 127 mm.
|
Imperial Adapter Sleeves
(Split) |

Split Adapter Sleeves can be used to increase the body diameter of 8 mm sensors to 9.512 (3/8"). Available in lengths A from 12 to 127 mm.
|
|
|
|
 |
|
|
|
AJ/P Analogue Pneumatic Push Probe - Specification
AJ/P Series |
Axial Cable Outlet (LVDT) |
A6J/1/P |
AJ/1/P |
AJ/1.5/P |
AJ/2.5/P |
AJ5/1/P |
AJ/5/P |
AJ/10/P |
Axial Cable Outlet (Half Bridge) |
A6J/1/PH |
AJ/1/PH |
AJ/1.5/PH |
AJ/2.5/PH |
AJ5/1/PH |
AJ/5/PH |
AJ/10/PH |
Body Diameter |
6h6 |
8h6 |
Measurement Range (mm) |
± 1.0 |
± 1.0 |
± 1.5 |
± 2.5 |
± 1.0 |
± 5.0 |
± 10.0 |
Pre-Travel (mm) |
0.15 |
Over Travel (mm) |
0.35 |
0.85 |
8.85 |
0.85 |
Accuracy (% of reading or µm, whichever greater) |
0.5, 1.0 µm |
0.5, 1.0 µm |
0.5, 1.5 µm |
0.5, 2.5 µm |
0.5, 1.0 µm |
0.5, 5.0 µm |
0.7, 10.0 µm |
Repeatability (µm) |
<0.15 |
Tip Force (N) at Centre Travel ± 20% |
1.0 @ 1 bar |
0.85 @ 1 bar |
0.7 @ 1 bar |
Resolution |
Dependent on electronics |
Temperature Coefficient (% FS/°C) |
0.02 |
0.01 |
|
Electrical Interface |
LVDT Plugged |
Sensitivity1 (mV/V/mm) ± 0.5% |
200 |
200 |
133 |
80 |
200 |
40 |
20 |
Energising Current (mA/V) ± 5% |
3.0 |
1.8 |
2.0 |
2.0 |
1.8 |
2.0 |
1.0 |
LVDT Unplugged |
Sensitivity (mV/V/mm) ± 5% |
269 |
210 |
150 |
150 |
210 |
105 |
33 |
Half Bridge Plugged |
Sensitivity1 (mV/V/mm) ± 0.5% |
73.5 |
73.5 |
49.0 |
29.4 |
73.5 |
14.7 |
7.35 |
Energising Current (mA/V) ± 5% |
1.2 |
1.0 |
1.0 |
1.0 |
1.0 |
1.2 |
1.2 |
Half Bridge Unplugged |
Sensitivity ± 5% |
88 |
83 |
150 |
150 |
210 |
105 |
33 |
1Linearity and Sensitivity error combined does not exceed a total of 0.5%. |
Environmental |
Storage Temperature (°C) |
-40 to +100 |
Operating Temperature (°C) |
+5 to +80 |
IP Rating |
None |
|
Materials |
Case |
Stainless Steel |
Probe Tip |
Nylon and Tungsten Carbide |
Gaiter |
High Grade Polymer |
Cable |
2 m PUR |
|
|
|
|