AX/P Series Analogue Pneumatic Push Probe - Specification
|
AX/P Series |
|
Axial Cable Outlet (LVDT) |
AX/1/P |
AX/1.5/P |
AX/2.5/P |
AX5/1/P |
AX/5/P |
AX/10/P |
|
Axial Cable Outlet (Half Bridge) |
AX/1/PH |
AX/1.5/PH |
AX/2.5/PH |
AX5/1/PH |
AX/5/PH |
AX/10/PH |
|
Body Diameter |
8h6 |
|
Measurement Range (mm) |
± 1.0 |
± 1.5 |
± 2.5 |
± 1.0 |
± 5.0 |
± 10.0 |
|
Pre-Travel (mm) |
0.15 |
|
Over Travel (mm) |
0.85 |
8.85 |
0.85 |
|
Accuracy (% of reading or µm, whichever greater) |
0.5, 1.0 µm |
0.5, 1.5 µm |
0.5, 2.5 µm |
0.5, 1.0 µm |
0.5, 5.0 µm |
0.7, 10.0 µm |
|
Repeatability (µm) |
<0.15 |
|
Tip Force (N) at Centre Travel ± 20% |
0.8 @ 0.4 bar
2.8 @ 1 bar |
0.8 @ 0.4 bar
2.8 @ 1 bar |
0.85 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
0.7 @ 0.4 bar
2.5 @ 1 bar |
|
Resolution |
Dependent on electronics |
|
Temperature Coefficient (% FS/°C) |
0.01 |
|
|
|
Electrical Interface |
|
LVDT Plugged |
|
Sensitivity1 (mV/V/mm) ± 0.5% |
200 |
133 |
80 |
200 |
40 |
20 |
|
Energising Current (mA/V ± 5%) |
1.8 |
2.0 |
2.0 |
1.8 |
2.0 |
1.0 |
|
LVDT Unplugged |
|
Sensitivity (mV/V/mm) ± 5% |
210 |
150 |
150 |
210 |
105 |
33 |
|
Half Bridge Plugged |
|
Sensitivity1 (mV/V/mm) ± 0.5% |
73.5 |
49.0 |
29.4 |
73.5 |
14.7 |
7.35 |
|
Energising Current (mA/V ± 5%) |
1.0 |
1.0 |
1.0 |
1.0 |
1.2 |
1.2 |
|
Half Bridge Unplugged |
|
Sensitivity ± 5% |
83 |
150 |
150 |
210 |
105 |
33 |
|
1Linearity and Sensitivity error combined does not exceed a total of 0.5%. |
|
Environmental |
|
Storage Temperature (°C) |
-40 to +100 |
|
Operating Temperature (°C) |
+5 to +80 |
|
IP Rating |
IP 65 |
|
|
|
Materials |
|
Case |
Stainless Steel |
|
Probe Tip |
Nylon and Tungsten Carbide |
|
Gaiter |
High Grade Polymer |
|
Cable |
2 m PUR
|
|
|
|
|
|
Analogue Automatic Probes
Pneumatic Probes are ideal for use in automatic gauging applications or for accessing details that would be difficult or impossible to reach using conventional spring push probes. Some materials such as glass or plastic, for example, require very low tip forces to avoid deforming the component and contact tip materials that do not leave mark. Other applications may require higher tip forces.
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
Clamping Collet |
Ø9.5 mm |
Ø10 mm |
|
805048 (M4 Screw)
806788 (M3 Screw)
|
806460-SX (M4 Screw) |
|

|

|
|
For use with all 8 mm clamping shaft sensors. The clamping collet distributes the clamping forces evenly around the shaft. Using the supplied grub screw, the probe can be loosened while holding the collet in place. |
|
Finger Lifter |

The Finger Lifter is used for manual operation of spring push Linear Encoders and prevents heat being transferred to the shaft. Part Number 206678
|
|
Replacement Gaiters |

Gaiters can be replaced when damaged. Only pneumatic push probes require gaiter rings.
Part Numbers:
|
Spring Push |
|
Part Number |
Pneumatic Push |
Part Number |
|
|
LE/12/S |
209562 |
|
LE/12/P |
805098 |
|
|
LE/25/S |
205906 |
|
LE/25/P |
804241 |
|
|
Imperial Adapter Sleeves |

Adapter Sleeves can be used to increase the body diameter of 8 mm sensors to 9.512 (3/8"). Available in lengths A from 12 to 127 mm.
|
Imperial Adapter Sleeves
(Split) |

Split Adapter Sleeves can be used to increase the body diameter of 8 mm sensors to 9.512 (3/8"). Available in lengths A from 12 to 127 mm.
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
Digital Linear Encoder - Specification
|
Digital Linear Encoder |
|
|
Spring Push |
Pneumatic Push |
|
IP 50 |
LE/12/S |
LE/25/S |
|
|
|
IP 65 |
LE/12/S |
LE/25/S |
LE/12/P |
LE/25/P |
|
Measurement Range (mm) |
12 |
25 |
12 |
25 |
|
Mechanical Travel Range (mm) |
13 |
26 |
13 |
26 |
|
Accuracy (µm) |
± 0.4 |
|
Repeatability (µm) |
< 0.1 |
|
Resolution (µm) |
0.05 |
|
Reference Mark Position |
Approximately 3 mm from end stop |
|
Tip Force (N) ±20%: Up |
0.1 |
|
Down |
0.6 |
|
Horizontal |
0.5 |
|
Temperature Coefficient (µm/ºC) |
-0.35 to -0.5 |
|
Max. Gauge Speed m/s |
0.5 |
|
|
|
Mechanical |
|
Mounting (stem diameter) |
∅ 8h6
|
|
Material: Scale
|
Quartz Glass
|
|
Shaft |
Hardened Stainless Steel |
|
Gaiter |
Flouroelastomer (IP65 Only) |
|
∅ Contact Tip |
Nylon, Tungsten Carbide, Ruby or Silicon Nitride |
|
Cable
|
PUR |
|
|
|
Environmental |
|
Storage Temperature (ºC) |
-20 to +70 |
|
Operating Temperature (ºC) |
+5 to +60 |
|
IP Rating |
IP50 or IP65 |
IP65 |
|
|
|
Digital Probe Interface Electronics |
|
Output |
Serial RS485 signal level |
|
Orbit Network Protocol |
|
|
Power (VDC) |
5 ± 0.25 @ 0.07 A (includes power for probe) |
|
IP Rating |
IP43 (IP65 available) |
|
CE Marking |
Immunity: EN61000-6-2 Emissions: EN61000-6-3 |
|
Operating Temperature (ºC) |
0° to +60 °C |
|
Measurement Modes |
Standard, Dynamic, Dynamic 2, Readburst |
|
Reading Rate |
3906 readings/s |
|
Materials |
Nylon and ABS plastic |
|
Cable Length (m) |
2.0 (standard, other options available) |
|
Weight (grams) |
Probe Interface Electronics 52