Vertical Float Type KF-100 Series
 

Features

Resistant to change of properties and environments including vapors and gases, highly reliable, and easy to maintain!

 

  •  There are no moving parts excluding the float, with high reliability and ease of maintenance
  •  Due to the read switch composition, there is no influence by changes of properties and environments including vapors and gases
  •  As the wetted surface is composed of SUS or corrosion-resistant resin, the meters can be used for various types of liquids
 
 

Operating Principles

A read switch (SW) and resistance (R) are provided inside the stem. When the read switch contact at the position moved by the magnet in the float or liquid level change closes, the liquid level change is detected as a change of the resistance. This is output as a DC 4 to 20 mA current signal by the resistance-current converter.

 

 

 

 

 

 

 

 

 

 

 

 

 

  KF-100 image
 

Specifications

Amplifier Specification
Power Source  AC100/200V ±10%  50/60Hz
 (Power of DC24V may be possible)
Power Consumption  4VA
Allowable Temperature  0~+55℃(No freeze No condensation)
Input Signal  Resistance (Three wire type)
Input Impedance  Max.100kΩ(Detection impedance:1~3kΩ)
Output Signal  DC4~20mA (Resistance Load Max.500Ω)
Linearity  FS 1%
 

Product Lineup

 
 
KF-100
Wetted Parts (SS)
  KF-130
Wetted Parts (PVC)
 
 

 