ATM.ECO/IS - Analog Transmitter with Temperature Compensation |
|
DOWNLOADS
|
|
OVERVIEW
Features
-
Pressure measuring range: 100 mbar … 1000 bar
-
Accuracy: ≤ ± 0.25 % FS
-
Operating temperature: -40 … 125°C
-
Process temperature: -40 … 150°C
-
Output signal: 4 … 20 mA
-
Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
-
Materials: Stainless steel
-
Customer benefits
-
Pressure measuring range: 100 mbar … 1000 bar
-
Accuracy: ≤ ± 0.25 % FS
-
Operating temperature: -40 … 125°C
-
Process temperature: -40 … 150°C
-
Output signal: 4 … 20 mA
-
Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
-
Materials: Stainless steel
|
Back to Top |
SPECIFICATIONS
|
0.1 ... 0.5, (1) |
> 0.5 ... 2 |
> 2 ... 100 |
Overpressure |
3 bar |
3 x FS (≥ 3 bar) |
3 x FS |
Burst pressure, (4) |
> 200 bar |
> 200 bar |
> 850 bar |
Accuracy, (5), (± % FS) |
≤ 0.25 |
≤ 0.25 |
≤ 0.25 |
Total Error, (6), (± % FS) |
|
|
|
0 ... 70°C, (typ. / max.) |
≤ 1.0 / 1.5 |
≤ 0.7 / 1.0 |
≤ 0.7 / 1.0 |
-25 ... 100°C, (typ. / max.) |
≤ 2.0 / 2.5 |
≤ 1.0 / 1.5 |
≤ 1.0 / 1.5 |
Response time, (typ.) |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
Long term stability, (7) |
< 0.5% FS / < 4 mbar |
< 0.2% FS / < 4 mbar |
< 0.1% FS / < 0.2% FS |
|
> 100 ... 600, (2) |
> 600 ... 1000, (3) |
Overpressure |
3 x FS (≤ 850 / ≤ 1500 bar) |
1500 bar |
Burst pressure, (4) |
> 850 / ≤ 1500 bar |
> 1500 bar |
Accuracy, (5), (± % FS) |
≤ 0.25 |
≤ 0.25 |
Total Error, (6), (± % FS) |
|
|
0 ... 70°C, (typ. / max.) |
≤ 0.7 / 1.0 |
≤ 0.7 / 1.0 |
-25 ... 100°C, (typ. / max.) |
≤ 1.0 / 1.5 |
≤ 1.0 / 1.5 |
Response time, (typ.) |
< 1ms / 10 ... 90% FS |
< 1ms / 10 ... 90% FS |
Long term stability, (7) |
< 0.1% FS / < 0.2% FS |
< 0.1% FS / < 0.2% FS |
|
4 ... 20 mA |
Power supply |
9 ... 28 VDC |
Supply influence |
< 0.05% FS |
Circuit diagram |
|
Load resistance |
|
Load influence |
< 0.05% FS |
|
[SpalteLeer] |
[SpalteLeer] |
[SpalteLeer] |
Certificate, (1) |
SEV 09 ATEX 0108 X |
IECEx SEV 10.0003 X |
IECEx MSC 14.0002 X |
Gas |
II 1G Ex ia IIB/IIC T3 ... T6 |
EN 60079-0 / -11 / -26 |
|
Dust |
II 1D Ex ia IIIC IP6x T140°C ... T70°C |
EN 61241-0 / -11 |
|
Mining |
I M1 Ex ia I |
EN 50303 |
|
Temperature class, (2) |
T6 |
T4 |
T3 |
Process temperature |
-40 ... 50 °C |
-40 ... 100 °C |
-40 ... 150 °C |
Ambient temperature |
-40 ... 50°C |
-40 ... 90°C |
-40 ... 125°C |
Maximum values of the intrinsically safe circuit |
28V / 93 mA / 0.65W |
|
|
|
Back to Top |
CERTIFICATES
Certificate of compliance FMC ATM.xxx-IS STS E
Certificate of compliance FM ATM.xxx-IS STS E
IECEx SEV 10.0003X Issue 2
SEV09-ATEX 0108X ATEX ATM.xxx STS E
|
|
|
|
|