LDM-Series - Laser Micrometer Display Units
|
SPECIFICATIONS
|
2000/400 Scan type |
|
LDM-110 |
LDM-110EX |
LDM-1000 |
LDM-1000EX |
Picture |
|
|
|
|
No. of Axes |
For Single |
Max. 2 |
Max. 5 |
Max. 3 |
Scanning cycle |
400 times/sec |
400 times/sec |
400 times/sec |
400 times/sec |
No. of Averaging time |
1-2048
(16 steps) |
1-2048
(8 steps) |
1-2048(22 steps) at LDM-1000LS
1-1024(19 steps) at LDM-1000XY |
Measuring mode |
16 kinds |
8 kinds
(X,Y axis each) |
16 kinds + Optional edges measurement
per each axis |
Processing function |
NG |
Average, Difference, Large dia. measurement, etc. |
Cable cover(Wall) thickness processing |
NG |
NG |
OK(by LDM-1000XY) |
Display device |
7 segment LED |
Graphic LCD |
7 segment LED |
No. of Display digit |
4-5 digits |
4-5 digits |
3-6 digits |
3-6 digits |
Processing contents monitor |
NG |
NG |
OK |
OK |
Center position monitor |
LED(8pcs) |
LED(8pcs)
(X,Y axis each) |
Graphic bargraph
per each axis |
LED(8pcs) per each axis |
No. of channel of Recorder output |
1 |
1 |
1 channel per board(LDM-1000LS/XY) |
Recorder output performance |
Max.+/-10V, Resolution 12bits(=approx.10mV/1bit),
Output impedance 100ohm(approx.),
Deviation/Absolute value switch over available |
Recorder output gain |
1μm-1m/V(decade steps) |
0.1μm~1m/V(decade steps) |
Digital dia. controller connection |
OK |
OK |
NG |
NG |
Center value setting |
5 digits |
5 digits |
6 digits |
6 digits |
High/Lo limit tolerance setting |
4 digits |
4 digits |
6 digits |
5 digits |
High/Low limit contact output |
1a contact(*2) |
1a contact(*2) per board(LDM-1000LS/XY) |
Contact rating: AC250V 2A(Resistance load) |
Error contact output |
1b contact(Close when power OFF) |
1b contact(Close when power OFF)(Combined use by each board) |
Contact rating: AC250V 2A(Resistance load) |
Laser remote terminal |
OK |
OK (X,Y common) |
OK(each LDM-1000LS board) |
Hold terminal |
OK |
OK (X,Y,P common) |
OK(each LDM-1000LS/XY board) |
Edge monitoring function |
OK |
OK |
OK |
OK |
Self-diagnosis mode |
OK |
OK |
OK |
OK |
Multi-point calibration function |
OK |
NG |
NG |
NG |
Trigger function (Max. meas., Deviation meas., etc.) |
NG |
NG |
OK |
OK |
Offset function |
NG |
NG |
OK |
OK |
Zero set function |
OK |
NG |
OK |
OK |
mm/inch changeover function |
NG |
NG |
OK |
OK |
Programing function |
NG |
NG |
OK(30 kinds) |
OK(9 kinds) |
Graph display |
NG |
NG |
OK |
NG |
Serial port |
OK |
OK |
OK |
OK |
BCD output |
Option |
OK(by LDM-1000BCD) |
RS-485 Function |
Option |
NG |
Cable length |
Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) |
Power supply |
AC100-240V Free power supply 50/60Hz |
Power consumption |
less than 11VA |
less than 14VA |
less than 15VA(only display unit)
less than 8VA(each board) |
Ambient condition |
Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) |
Outside dimension |
144(W) * 72(H) * 191(D)[mm] |
216(W) * 144(H) * 225(D)[mm] |
Weight |
Approx. 1.5kg |
Approx. 1.6kg |
Approx. 4kg (only display unit)
Approx. 280g (each board) |
|
|
2000/400 Scan type |
|
LDM-210 |
LDM-210C |
LDM-210EXC |
Picture |
|
|
|
No. of Axes |
For Single |
Max. 2 |
Scanning cycle |
2000 times/sec or 400 times/sec |
No. of Averaging time |
1-2048 (12 steps) |
Measuring mode |
Optional edges measurement per each axis |
Processing function |
NG |
Average, Difference, Large dia. measurement, etc. |
Cable cover (Wall) thickness processing |
NG |
Display device |
7 segment LED |
No. of Display digit |
4-5 digits |
Processing contents monitor |
NG |
Center position monitor |
LED(8pcs) |
LED(15pcs) |
LED(8pcs) (X,Y axis each) |
No. of channel of recorder output
|
1 |
Recorder output performance |
Max.+/-10V, Resolution 12bits(=approx.10mV/1bit),
Output impedance 100ohm(approx.),
Deviation/Absolute value switch over available |
Recorder output gain |
1μm-1m/V(decade steps) |
Digital dia. controller connection |
OK |
NG
(Built-in Dia.Controller) |
Center value setting |
5 digits |
High/Lo limit tolerance setting |
5 digits |
High/Low limit contact output
|
1a contact(*2) |
Contact rating: AC250V 2A(Resistance load) |
Error contact output |
1b contact(Close when power OFF) |
Contact rating: AC250V 2A(Resistance load) |
Laser remote terminal |
OK |
OK(X,Y common) |
Hold terminal |
OK |
OK(X,Y common) |
Edge monitoring function |
OK |
Self-diagnosis mode |
OK |
Multi-point calibration function |
OK |
Trigger function (Max. meas., Deviation meas., etc.)
|
NG |
Offset function
|
OK(Ver2.15 or more) |
NG |
Zero set function |
OK |
NG |
mm/inch changeover function |
NG |
Programing function |
NG |
Graph display |
NG |
Serial port |
OK |
BCD output |
Option |
RS-485 Function |
Option |
Cable length |
Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) |
Power supply |
AC100-240V Free power supply 50/60Hz |
Power consumption |
less than 15VA |
less than 20VA |
Ambient condition |
Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) |
Outside dimension |
144(W) * 72(H) * 191(D)[mm] |
144(W) * 72(H) * 241(D)[mm] |
Weight |
Approx. 1.5kg |
Approx. 1.8kg |
|
ADD-ONS
Signal Extender(LDM-201, LDM202) - extends cables when the distance between a scanning unit and a display unit exceeds 30 metres.
Signal Distributor(LDM-205, LDM-206) - divides output signals from a scanning unit.
BCD Distributor(LDM-B2)
|
|
|
|
Product & Technology News
LDM Series
Download Catalogue
|