Size of the detected variation (lump, neckdown or the like) can be seen at first sight on the display screen with 7 segments LED.Setting of 2 different detecting sensitivity level is available.
Data of the detected variation is saved inside the display unit and, the size and position of the variation can be captured via
RS-232C interface.
Mal-function caused by dust, bugs, outside random light, etc, can be vastly diminished due to the noise cancelling function.
Maximum 8 axes can be connected with single display unit.
SPECIFICATIONS
DETECTOR
Display unit
Model
TMS-1104W
Model
TMS-01
Detecting direction
4 axis
Sampling Friquency
75KHz(4axis)
Detection Method
Double-slit, infrared LED projection type
Main Display
7segmentLED 5digit
Detectable Outside Diameter
φ0.02~5mm
Sub Display
7segmentLED 2digit
Detecting Sensitivity
0.02~0.999mm
Recorder Output
0.1mm/V
Detecting Accuracy
+/-10μm. set value
Length Measurement input
encorder input
Slit length
18mm
Length Measurement power output
DC12V Max50mA
Slit width
0.5mm
Alarm Output
Relay contact output(AC250V 2A Resistance load)
Feeding speed[*1]
1m/min~1000m/min
Outside Contact input
Reset input
Response
3Hz~10KHz
RS-232C interface
OK
Cable Length
(Between Sensor/Display)
5m
Alarm Time
0.01~0.999Sec
Ambient Temperature
-5 - 50 degree centigrade
(No condensation)
Power Source
AC90~240V 50/60Hz
Power Consumption
17VA
Outside Dimension(W×H×D[mm])
350×280×55
Outside Dimension(W×H×D[mm])
144×144×210
Weight
3.5kg
Weight
3kg
[*1]Applicable Line speed range varies by variation height.